Technology
electromagnetic
Type
volume
Fluid
for water, for wastewater
Pipe diameter
DN25 - 1", DN300 - 12"
Material
polypropylene
Communication
4-20 mA, with pulse output, digital output, HART
Protection level
IP67, IP68, IP66
Applications
for water treatment, for wastewater treatment
Other characteristics
compact, high-accuracy, with display, with LCD display, electronic
Process temperature

Min.: -5 °C
(23 °F)

Max.: 90 °C
(194 °F)

Process pressure

Min.: 10 bar
(145.04 psi)

Max.: 40 bar
(580.15 psi)

Precision

0.5 %

Description

Product overview
The OPTIFLUX 2000 is an electromagnetic flowmeter for water and wastewater applications. It is available with PP or hard-rubber linings and holds multiple drinking-water approvals for PP-lined versions.

Highlights
  • Suitable for potable water applications (PP lining approvals)
  • Wear-free measuring principle (magnetic-inductive)
  • Wide dynamic measuring range and compact design


Technical data
Measuring principle: Magnetic-inductive
Nominal widths: DN 25 to DN 300
Accuracy: 0.5 % of measured value
Medium temperature: Up to 90 °C
Process connection: PN 40 (DN 25–DN 80), PN 16 (DN 100–DN 150), PN 10 (DN 200–DN 300)
Lining: PP, hard rubber
Ambient temperature: Up to 65 °C
Protection type: IP66/IP67 (IP68 for remote version)
Outputs: Analog (4–20 mA) with HART; pulse / frequency / status outputs
Display: LCD with white backlight, up to 3 measured values
Drinking-water approvals (PP lining): ACS, DVGW, KTW, WRAS, NSF, KIWA

Characteristics / technical specifications
  • Measuring principle: Magnetic-inductive
  • Nominal widths: DN 25 to DN 300
  • Accuracy: 0.5 % of measured value
  • Medium temperature: Up to 90 °C
  • Process connection: PN 40 (DN 25–DN 80), PN 16 (DN 100–DN 150), PN 10 (DN 200–DN 300)
  • Lining: PP, hard rubber
  • Ambient temperature: Up to 65 °C
  • Protection type: IP66/IP67; IP68 for remote version
  • Outputs: Analog 4–20 mA with HART; pulse / frequency / status
  • Display: LCD with white backlight, up to 3 measured values
  • Drinking-water approvals (PP): ACS, DVGW, KTW, WRAS, NSF, KIWA