- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- RS485 flow meter
RS485 flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Volumetric flow rate: 60 l/min - 320 l/min
Process temperature: 80 °C
Process pressure: 0 bar - 16 bar
... Overview
Wear- and maintenance-free ultrasonic measurement enables high-accuracy
flow measurement independent of fluid conductivity. The
meter is extendable with optional temperature and pressure sensors and ...
Mass flow rate: 0 kg/h - 860,000 kg/h
Process temperature: -50 °C - 205 °C
... series of compact system integration flowmeters feature low pressure drop, high flow capacity, high speed RS 485 Modbus communication and 2 digital outputs. With no up ...
Mass flow rate: 0 kg/h - 250,000 kg/h
Process temperature: -50 °C - 205 °C
... CoriolisMaster FCH100 series of compact hygienic system integration flowmeters feature low pressure drop, high flow capacity, high speed RS 485 Modbus communication and ...
Volumetric flow rate: 20 m³/h - 12,022 m³/h
Process temperature: -40 °C - 140 °C
Precision: 0.12 %
... the Panametrics line of ultrasonic flow meters for high-accuracy metering applications. Used primarily for measuring hydrocarbon liquids and water for critical use. the eight-path design of the LCT8 enables the meter ...
Panametrics
Volumetric flow rate: 5 m³/h - 75,639 m³/h
Process temperature: -40 °C - 140 °C
Precision: 0.15 %
The Panametrics Sentinel LCT4 is designed specifically for high accuracy measurement of crude oil, other liquid refined hydrocarbon products, and other non-hydrocarbon liquids, it delivers extremely reliable and repeatable results and meets the strict ...
Panametrics
Process temperature: -40 °C - 150 °C
Precision: 1, 2, 0.5 %
Repeatibility: 0.2 %
... AquaTrans AT600 is a liquid clamp-on flow meter designed to be accurate, durable and cost-effective. Rugged and reliable, this meter will remain fixed to your pipe for years to come. Applications The ...
Panametrics
Volumetric flow rate: 0 l/min - 500 l/min
Process temperature: -20 °C - 70 °C
Process pressure: 15 bar
... performance and high range ability Gas Flow Meters. Description The CMS series of gas mass flow meters employs our proprietary thermal flow rate sensor as the sensing ...
Process temperature: -20 °C - 60 °C
Precision: 0.4 %
Repeatibility: 0.1 %
... ELECTROMAGNETIC FLOWMETER
HIGH-PRECISION FLOW MEASUREMENT FOR WATER NETWORKS WITHOUT EXTERNAL POWER SUPPLY
The M5000 self-powered electromagnetic
flowmeter is designed for accurate ...
FUJI ELECTRIC France
Process temperature: -273 °C - 200 °C
Precision: 1 %
... open collector contacts
APPLICATIONS
- This flowmeter
FUJI ELECTRIC France
Precision: 0.3 %
Repeatibility: 0.1 %
... ELECTROMAGNETIC
FLOWMETER M1000
- Bidirectional flow measurement for liquids with conductivity above 5 μS/cm, and above 20 μS/cm for demineralized water.
- Accuracy of ± 0.3% of measured flow
FUJI ELECTRIC France
... ultrasonic technology for mobile and highly accurate flow measurements Special features: ■ Very high measurement accuracy (also bidirectional) ■ Accurate even at extremely low flow rates (e.g. minimum night flow) ■ ...
Volumetric flow rate: 0.2 m³/h - 848.2 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 0 bar - 16 bar
... Inline Flow Sensor for Compressed Air and Gases Versatility The modular and compact EE741 is dedicated for accurate metering and monitoring of compressed air and technical gases such as O2, N2, Ar or CO2 in DN15 to DN50 pipes. Measuring ...
Volumetric flow rate: 1.7 m³/h - 263,350 m³/h
Process pressure: 0 bar - 16 bar
... Insertion Flow Sensor for Compressed Air and Gases DN50 - DN700 (2" - 28") The EE776 employs the thermal mass flow measurement principle and is suitable for pipe diameter DN50 (2") to DN700 (28"). It is ideal for monitoring ...
Process temperature: -40 °C - 130 °C
Precision: 1 %
Repeatibility: 0.15 %
... other meter technologies, such as magnetive inductive meters, can increase so dramatically in the low flow range, that they are unsuitable for monitoring minimum night flows. But for ...
Process temperature: -40 °C - 100 °C
Precision: 2 %
... portable clamp-on ultrasonic water flow meter The FLUXUS F401 is the ideal flow meter for long-term measurement campaigns in the field. Depending on the programmed measurement interval ...
Process temperature: -200 °C - 600 °C
Precision: 0.3, 1 %
... clamp-on gas flow meter the standard setting measuring solution for any industrial application - even for the most challenging ones. The meter adapts itself automatically to the respective measurement ...
Mass flow rate: 0 kg/h - 2,200,000 kg/h
Process temperature: -196 °C - 240 °C
Process pressure: 100 bar
... process safety – immune to fluctuating and harsh environments Fewer process measuring points – multivariable measurement ( flow, density, temperature) Space-saving installation – no in-/outlet run needs Full access to process ...
Endress+Hauser AG
Process temperature: -200 °C - 427 °C
Process pressure: 150 psi - 1,500 psi
Precision: 0.7, 2, 1.3, 1.2, 1.6 %
... included in every meter simplifies electronics verification All meters arrive pre-configured and hydrostatically tested, making them ready and easy to install Simplify SIS compliance with available dual and quad Vortex ...
Emerson Automation Solutions - ROSEMOUNT
Volumetric flow rate: 0.4 l/min - 25,400 l/min
Process temperature: 0 °C - 50 °C
Precision: 1.5 %
... Display of Flow Rate and Total • 4 to 20 mA Re-transmission of Flow Rate (DIN 50 and smaller sizes only) • RS 485 Communications (Modbus®) • For Most Clean Liquids ...
Process temperature: -40 °C - 150 °C
... t2 are measured by an electronic flow transmitter. The signal from transducer A towards transducer B is accelerated by the flow (short t1). The return signal from transducer B to transducer A is decelerated by the flow ...
Process temperature: 0 °C - 80 °C
Process pressure: 3.5 bar - 7.5 bar
Repeatibility: 0.03 % - 0.3 %
... less for improved throughput High Accuracy Flow rate accuracy for process gas has been improved with an advanced three-dimensional adjustment Fast Response Response: < 0.8 second Accurate, stable flow control ...
Process temperature: 0 °C - 50 °C
... Analog: 4 to 20 mA DC, 1 point; Digital: Open Collector: 1 point; Relay Contact: 1 point. Serial Communications: RS- 232C or RS- 485. Enclosure Rating: IP65. Materials: - Plastic ABS. Electrical ...
Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the ...
Pulsar Measurement
Process temperature: -20 °C - 150 °C
Process pressure: 40, 10, 16, 6 bar
Precision: 0.25, 0.5 %
... lengths. Therefore, the flowmeter provides very accurate measurements - even over a large area. With electromagnetic flowmeters from MJK, you are guaranteed stable, accurate measurements for years. If you want to know ...
MJK
Precision: 2 %
... easily mounted on the pipe. The flow meter's display provides information on flow velocity, date, and time. In another view, it also displays the volume flow rate for the day, month, ...
Process temperature: -10 °C - 40 °C
... integrated, good looking appearance. Built-in industrial lithium battery. Low- flow measurement function available All-in-one detect probe, measure flow velocity, temperature, presure and methane concentration ...
Cubic Sensor and Instrument Co.,Ltd
Process temperature: -40 °C - 60 °C
... gas flow meter is an advanced electronic meter for natural gas flow measurement, which adopts ultrasonic technology to maintain long-term accuracy without degradation. With its multipath ...
Cubic Sensor and Instrument Co.,Ltd
Process temperature: -20 °C - 60 °C
... flue duct. This flowmeter adopts the non-contact measurement method, which can effectively solve the measurement difficulties such as unstable flow field and uneven flow velocity distribution in the ...
Cubic Sensor and Instrument Co.,Ltd
Volumetric flow rate: 0.015 l/min - 83 l/min
Process temperature: -40 °C - 80 °C
Process pressure: 200, 50 bar
... Designed for precise flow measurement, the volumetric flow meter is suitable for continuous or intermittent monitoring of liquid flow or instantaneous flow ...
... compressed air flow meter is designed to be easy to use, affordable and it's offering a wide measurement range. This makes it easy for you to choose the right flow meter, the S401 which ...
Volumetric flow rate: 0 m³/h - 2,545 m³/h
Process temperature: -25 °C - 90 °C
Process pressure: 4, 2.5, 1.6 MPa
... Electromagnetic flowmeter type PEM-500 is applicable to the measurement of flow of the liquids with minimum conductivity of 5ěS/cm. Device measures flow and volume of liquids in both directions of flow. ...
Volumetric flow rate: 1 l/h - 600 l/h
Process temperature: -40 °C - 85 °C
Process pressure: 2 bar - 25 bar
... heating) oil and other liquids with kinematics viscosity of 1.5 cSt to 6 cSt can be measured by DFM. DFM fuel flow meter can be used as stand-alone flow measurement solution or can be integrated intro ...
TECHNOTON
Volumetric flow rate: 1 l/h - 500 l/h
Process temperature: -40 °C - 85 °C
Process pressure: 2 bar - 25 bar
... with kinematics viscosity of 1.5 cSt to 6 sSt can be measured by DFM. DFM fuel flow meter is a tool for direct fuel consumption measurement, the data from the flow meter is used in ...
TECHNOTON
Volumetric flow rate: 10 l/h - 600 l/h
Process temperature: -40 °C - 85 °C
Process pressure: 2 bar - 25 bar
... engines with CommonRail fuel injection system and analogs. DFM D differential fuel flow meter is a tool for direct fuel consumption measurement, the data from the flow meter is used ...
TECHNOTON
Volumetric flow rate: 0 l/min - 525 l/min
Process temperature: -40 °C - 210 °C
Process pressure: max 450.0 bar
... VSI+
flowmeters measure the volume
flow of the medium according to the gearwheel
principle. A gearwheel pair fitted very precisely in the housing forms the measuring
unit. The rotation of the measuring unit ...
VSE Volumentechnik GmbH
Volumetric flow rate: 0 l/min - 525 l/min
Process temperature: -40 °C - 210 °C
Process pressure: 0 bar - 450 bar
... Our VS gear flow meters offer unbeatable performance, linearity and resolution for most accurate measurement of clear, viscous liquids according to the gearwheel principle. A gearwheel pair adapted with precision into ...
VSE Volumentechnik GmbH
Volumetric flow rate: 0 l/min - 3,000 l/min
Process temperature: -40 °C - 210 °C
Process pressure: 0 bar - 450 bar
... viscosity oil or viscous resin - RS flow meters are the ideal solution for precise flow measurement. Thanks to various bearings, tolerances, materials, coatings, electronics and resolutions, ...
VSE Volumentechnik GmbH
Volumetric flow rate: 0 l/min - 10,000 l/min
Precision: 0.2, 0.5 %
Repeatibility: 0.15 %
... Analog and Digital Output 0-5VDC, 0-10VDC, 4-20mA RS232, RS 485, USB Flow ...
Volumetric flow rate: 0 l/min - 2,500 l/min
Process pressure: 0 bar - 34.47 bar
Precision: 0.5, 0.2 %
... Mass flow techniques provide RELIABLE, REPEATABLE AND ACCURATE gas flow rate measurements. HFM-D-306A/HFC-D-308A mass flow instruments have flow ranges from 0-2500 slm to 0-10000 slm; ...
... configurability and local control over the instrument. DIGITAL COMMUNICATIONS. The Digital 300B Sériés is equipped with RS232, RS 485 and USB for digital communications. The USB connector serves as a ...
Process temperature: 0 °C - 120 °C
Process pressure: 10 bar
... or ducts • No real upper limit of mass flow • Maximum pressure 10 bar • Dust tight • No flow restrictions to the process flow (wear resistant ceramic liner) • The mass flow measurement ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group