DescriptionThe MFE600-E Electromagnetic Flowmeter is an industrial-grade volumetric flow measuring instrument designed for reliable liquid flow measurement across a wide range of pipe sizes and process conditions. It integrates dedicated hardware and software and is manufactured with traceable flow calibration to ensure consistent metrological performance.
Advantages- Measurement unaffected by fluid density, viscosity, temperature, pressure or conductivity variations within operating limits.
- No obstruction in flow path and negligible pressure loss.
- Compact design, easy installation; minimal straight pipe run required.
- No mechanical inertia, fast response and good linearity; suitable for pulsating or intermittent flows.
- Sensor lining and electrodes contact the medium; selectable materials provide chemical and wear resistance for long service life.
- Multi-electrode configurations ensure high accuracy; many sizes do not require grounding rings.
- EEPROM stores device parameters and cumulative flow during power-off.
- Transmitter uses a low-power microcontroller with stable zero; dot-matrix LCD shows total flow, instantaneous flow, velocity and flow percentage.
- Bidirectional measurement (positive/negative flow); low-frequency excitation improves stability and low-flow performance.
- Optional integrated pressure measurement for simultaneous flow and pressure monitoring.
Technical table (key items)Diameter: Flanged DN3 ~ DN2400; Hygienic DN6 ~ DN50; Threaded DN6 ~ DN50; Wafer DN10 ~ DN300
Accuracy: Class 0.5, 0.2
Electrode types: Standard fixed, anti-fouling; DN6–DN20: one pair measuring electrodes (no grounding); DN25–DN500: one pair measuring + one pair grounding; ≥DN600: two pairs measuring + one pair grounding
Construction types: Integral, remote (remote cable ≤ 99 m)
Explosion-proof mark: Ex db ib mb IIC T6 Gb
Rated pressure: GB: PN2.5–PN320; ANSI: CLASS 150–1500; DIN: PN10–PN100; JIS: 5K–63K; Others: custom
Electrode materials: 316L, Titanium (Ti), Hastelloy (HB/HC), Tantalum (Ta), Tungsten carbide (WC), Pt-Ir, Ceramic
Lining: CR, NR, PU; PTFE / F46 / PFA; Ceramic
Meter tube: 304 SS
Flange and body: Carbon steel, 304 SS, 316L SS
Transmitter housing: Cast aluminum, 304 SS
Power supply: 220 VAC; 12 V DC, 24 V DC; Battery-powered (variants with LCD, RS485, wireless, frequency/pulse output — frequency/pulse mainly for calibration)
Output signal: 4–20 mA (active, load 0–750 Ω); HART; Frequency/pulse (optional passive/active); Alarm outputs; RS485 (Modbus), RS232; Profibus-DP/PA
Electrical port: M20×1.5 (female), NPT 1/2 (female)
IP rating: IP65 / IP67 / IP68 (sensor immersion; transmitter IP65) suitable for instrument wells
Ambient temperature: -20 °C ~ 60 °C (option -40 °C ~ 60 °C)
Storage temperature: -40 °C ~ 60 °C
Relative humidity: 5% ~ 90%
Industry application- Petroleum and oil processing
- Chemical and petrochemical plants
- Power generation
- Steel industry
- Cement plants
- Pulp and paper
- Water conservancy and treatment
Technical specifications- Model: MFE600-E
- Diameter options: Flanged DN3–DN2400; Hygienic/Threaded DN6–DN50; Wafer DN10–DN300
- Accuracy classes: 0.5, 0.2
- Electrode materials: 316L, Ti, Hastelloy (HB/HC), Ta, WC, Pt-Ir, Ceramic
- Lining materials: CR, NR, PU, PTFE/F46/PFA, Ceramic
- Meter tube: 304 stainless steel
- Flange/body materials: Carbon steel, 304 SS, 316L SS
- Transmitter housing: Cast aluminum or 304 SS
- Power supply options: 220 VAC, 12 V DC, 24 V DC, battery-powered variants
- Outputs: 4–20 mA, HART, frequency/pulse, alarm outputs, RS485 (Modbus), RS232, Profibus-DP/PA
- Electrical ports: M20×1.5 (female), NPT 1/2 (female)
- IP rating: IP65 / IP67 / IP68 (sensor)
- Operating temperature: -20 °C to 60 °C (option -40 °C to 60 °C)
- Storage temperature: -40 °C to 60 °C
- Relative humidity: 5%–90%
- Construction: Integral or remote transmitter (remote cable ≤ 99 m)
- Explosion-proof: Ex db ib mb IIC T6 Gb (available)