- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Analog output flow meter
Analog output flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Volumetric flow rate: 0.0009 m³/h - 4.5 m³/h
Precision: 1 %
... ul>
Process temperature: -20 °C - 90 °C
Process pressure: 0 bar - 16 bar
... loss and flow range
Features & Options
- Measurement
Process temperature: -25 °C - 120 °C
... Water flow meter / OPTIFLUX 1000 The OPTIFLUX 1300 is an electromagnetic flowmeter (EMF) with lightweight wafer-style design. The meter is an economical solution for applications with ...
Volumetric flow rate: 60 l/min - 320 l/min
Process temperature: 80 °C
Process pressure: 0 bar - 16 bar
... reduced accuracy)
Nominal pressure: PN 16
Ambient temperature: up to 60 °C
Outputs/communications: IO-Link (configurable: pulse
output up to 10 kHz,
analog
output, binary I/O); ...
Volumetric flow rate: 0.0003 m³/h - 9 m³/h
Precision: 0.5 %
... Measurement range suitable for very low to moderate flows
Technical data
Flow ...
Volumetric flow rate: 0.1 l/min - 900 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 16 bar
... With volumetric flow quantity, total quantity and temperature indication High accuracy, repeatability and measurement dynamics For use in conductive media from 20 μS/cm With switching output, analogue ...
Volumetric flow rate: 0.5 l/min - 150 l/min
... conductivity (deionised water) Vortex flow meters The SV range flow sensors monitor hydrous media and reliably detect the volumetric flow quantity. For more demanding tasks, sensors ...
Volumetric flow rate: 50 l/min - 200 l/min
... volumetric flow quantity. The result is displayed on the unit for signal processing. The system is particularly suited for monitoring cooling circuits. The device uses binary, analogue and pulse outputs ...
... ultrasonic technology for mobile and highly accurate flow measurements Special features: ■ Very high measurement accuracy (also bidirectional) ■ Accurate even at extremely low flow rates (e.g. minimum night flow) ■ ...
Volumetric flow rate: 0 l/min - 0.1 l/min
Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 5 bar
... min, conventional flow measurement breaks down. Azbil's micro flow rate liquid flowmeter F7M uses MEMS sensing technology to measure stable flow rates starting at 0.1 mL/min, a range ...
Volumetric flow rate: 0 l/min - 500 l/min
Process temperature: -20 °C - 70 °C
Process pressure: 15 bar
... High performance and high range ability Gas Flow Meters. Description The CMS series of gas mass flow meters employs our proprietary thermal flow rate ...
... Description The Magnew3000 PLUS⁺ electromagnetic flowmeter offers high performance, and high reliability based on the azbil Group's field-proven technologies. The model MGG14C converter provides expanded flow rate ...
Process temperature: -273 °C - 200 °C
Precision: 1 %
... li>
FUJI ELECTRIC France
Process temperature: -40 °C - 200 °C
Precision: 1 %
... oil
FUJI ELECTRIC France
Process temperature: -20 °C - 80 °C
Repeatibility: 1.5 %
... ULTRASONIC
FLOWMETER M-
FLOW PW – FLR CONVERTER
HIGH-PRECISION SOLUTION FOR LIQUID FLOW MEASUREMENTHIGH-PRECISION
The Fuji Electric M-
Flow PW Fixed ...
FUJI ELECTRIC France
Volumetric flow rate: 0.32 ft³/min - 1,400 ft³/min
Process temperature: -20 °C - 80 °C
Process pressure: 0 bar - 16 bar
... voltage output, switch output or as pulse output for consumption measurement. Optionally, the measured data is available at the Modbus RTU or M-BUS ( Meter-Bus) interface. User Configurable ...
Volumetric flow rate: 0 l/min - 350 l/min
Process temperature: -40 °C - 140 °C
Process pressure: 0 bar - 16 bar
... Magnetic Inductive Flowmeter ( Flow Meter) - All Metal - Stainless Steel - MIM Measuring range: 0.03 - 3 l/min ... 1.5 - 350 l/min liquids Accuracy: ±(0.8% of reading + 0.5% of FS) pmax: 16 bar tmax: ...
KOBOLD INSTRUMENTATION
Process temperature: -25 °C - 130 °C
Process pressure: 10, 40 bar
... without local LCD display – Universal wide range power supply – 1 analog output, 2 digital outputs Robust construction for rough environmental conditions – Hermetically sealed flow ...
ABB Measurement & Analytics
Volumetric flow rate: 0.1 ft³/s - 40 ft³/s
Process temperature: -23 °C - 60 °C
Process pressure: 0 psi - 10 psi
... unit features a large digital flow rate display with a totalizer, isolated 4-20 mA output, 26-million-point data logger, and two programmable control relays. Reverse Flow Measurement The ...
Pulsar Measurement
Volumetric flow rate: 0 l/min - 500 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 70,000 Pa - 1,500,000 Pa
... before the flow meter. This flow meter can measure and display as little as 1/100 of the maximum flow range. In the past, it was necessary to use multiple flow ...
Process pressure: 0.2 bar - 11 bar
Precision: 0.3, 0.5, 1 %
Repeatibility: 0.2 %
... gas flow control for industrial scientific OEM applications Ideal for washdown environments MEMS sensor stability-Lifetime no-drift sensor warranty - if drift occurs, instrument will be repaired or replaced free of ...
Sierra Instruments
Process temperature: -40 °C - 60 °C
... gas flow meter is an advanced electronic meter for natural gas flow measurement, which adopts ultrasonic technology to maintain long-term accuracy without degradation. With its multipath ...
Volumetric flow rate: 0.3 l/min - 140 l/min
Process temperature: -20 °C - 70 °C
... SONOFLOW CO.55 CLAMP-ON SENSOR - NON-CONTACT FLOW METERS FOR LIQUIDS IN FLEXIBLE TUBES The ultrasonic clamp-on flow meter SONOFLOW CO.55 measures the flow rate of ...
Volumetric flow rate: 14 l/min
Process temperature: 10 °C - 50 °C
... The hybrid flow-bubble sensors of the series SONOFLOW CO.56 Pro V2.0 and SONOFLOW CO.56 combine accurate flow measurement and reliable air bubble detection in liquid filled medical tubing. They feature a simple integration ...
Process temperature: -20 °C - 70 °C
Process pressure: 0 bar - 16 bar
... The SONOFLOW IL.52 ultrasonic flow sensor uses bidirectional measurement in order to achieve excellent precision, detecting even the smallest flow rates with speed and efficiency. It's construction and temperature resistance ...
Process temperature: 150 °C
Process pressure: 150 bar
... reagent in flue gas treatment and transport lines with very low material concentration Electrodynamic flow sensor for measurement of low flow rates from 0 to 100 kg/h. For pipe diameters up to 1 m. Ideally used ...
Mass flow rate: 0 kg/h - 5 kg/h
Volumetric flow rate: 2 l/min - 1,500 l/min
Process temperature: -10 °C - 55 °C
... category
Mass
flow sensing products: mass
flow
meters
MF3000
The MF3000 series mass
flow
meters are designed for general-purpose gas metering, ...
Volumetric flow rate: 0 l/min - 800 l/min
Process temperature: -10 °C - 55 °C
Process pressure: 1 MPa
... series mass flow meters are designed for general purpose flow metering and control applications and are made with Siargo's proprietary MEMS mass flow sensing technology and smart electronic ...
Process temperature: -10 °C - 100 °C
Process pressure: 0.2 MPa
Precision: 2.5 %
... probe with integration of temperature and humidity sensors. The air flow is calibrated in a wind-tunnel. The products are designed for acquiring the environmental data of air mass velocity, temperature and humidity ...
... sensor-fault detection and optional analog retransmission of sensor status.
Volumetric flow rate: 0.1 m³/h - 28,274 m³/h
Process temperature: -5 °C - 90 °C
Process pressure: 0 bar - 40 bar
... manufactured by Aplisens, is an electromagnetic flow meter equipped with a robust and resistant cover of sensor. It has a nominal size of DN 10 up to DN 1000, maximum static pressure of 40 bar and maximum analog ...
Process temperature: -20 °C - 70 °C
... ambient conditions. The large graphic display permits quick and easy commissioning of the flow meter system. Due to the modular construction of our radar flow meter system we can provide ...
Process pressure: 3 bar
... Compatible tube OD 9.5 mm up to 30 mm
Flow rate range: 0.2 ~ 150 L/min
Overview
- Clamp-on, non-intrusive ultrasonic flow meter for real-time flow
Volumetric flow rate: 0 l/min - 20 l/min
Process temperature: -20 °C - 110 °C
Process pressure: 30, 10 bar
... excellent accuracy over very wide flow ranges. The Atrato ultrasonic flow meter is a genuine breakthrough in flowmeter technology. Its rugged, clean bore construction makes the Atrato ...
Volumetric flow rate: 0 l/min - 5 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 20, 15 bar
... points and analogue and digital outputs can all be set through the USB connector and Titan’s proprietary interface software. Other parameters such as minimum flow cut-off, computer based ...
... the sensor settings like pipe diameter, gas type or analog output scaling. The sensor offers two different signal output options. It can have a isolated analog and pulse output ...
SUTO iTEC GmbH
Process temperature: -30 °C - 70 °C
Process pressure: 0 bar - 10 bar
Precision: 1.5 %
... Thermal mass flow with no additonal compensation required Perfect to measure your compressed air flow and consumption Economic and affordable compressed air flow meter - S415 ...
SUTO iTEC GmbH
Process temperature: -40 °C - 120 °C
Process pressure: 0 MPa - 5 MPa
Repeatibility: 0.25 %
... The S453 Compressed Air Flow Meter is specifically designed for heavy-duty and explosive (Ex) environments, providing precise and reliable thermal mass flow measurements for your industrial processes. ...
SUTO iTEC GmbH
Volumetric flow rate: 0.2 l/min - 80 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 10 bar
... Flow rate sensor with amplifier Magnetic-inductive measuring principle Flow indication with bright red 3-digit 7 segment indication Set-up via buttons at the device ...
Volumetric flow rate: 0.5 l/min - 5,000 l/min
Process temperature: -10 °C - 60 °C
Process pressure: -1 bar - 60 bar
... Flow measurement of waterbased liquids Temperature measurement Pipe diameter adjustable with IO-Link Teach-in functions Manipulation detection ...
Volumetric flow rate: 0 l/min - 525 l/min
Process temperature: -40 °C - 210 °C
Process pressure: max 450.0 bar
... Advantages of the VSI+ gear
flow
meters
- Highest accuracy and linearity
- Short response times
- Large variety (different bearings and materials,
- EX-protection)
- Digital
VSE Volumentechnik GmbH
Volumetric flow rate: 0 l/min - 3,000 l/min
Process temperature: -40 °C - 210 °C
Process pressure: 0 bar - 450 bar
... viscosity oil or viscous resin - RS flow meters are the ideal solution for precise flow measurement. Thanks to various bearings, tolerances, materials, coatings, electronics and resolutions, VSE finds ...
VSE Volumentechnik GmbH
Volumetric flow rate: 0.1 l/min - 150 l/min
Process temperature: 0 °C - 80 °C
Process pressure: 0 bar - 200 bar
... we have launched the VSE EF ecoflow series onto the market. The VSE EF ecoflow aluminium flow meter uses the same gearwheel pairs as in the VS. The flow meters work in accordance with ...
VSE Volumentechnik GmbH
Volumetric flow rate: 0 l/min - 2,500 l/min
Process pressure: 500 psi
Precision: 0.2 %
... mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen for its fast response under a wide range of conditions. . The HFM-305 / HFC-307 meters and controllers ...
... instrument. In this configuration the flow output is available as an analog signal and flow controllers will respond to analog commands. AUTO-ZERO. The Digital ...
Mass flow rate: 1 kg/h - 20,000 kg/h
Process temperature: -20 °C - 450 °C
Process pressure: 6, 30 bar
... Microwave-based flow measurement for bulk solids MF 3000 Numerous bulk material applications require continuous measurement of mass flow, e.g. for exact dosing of a material or to ...
Process temperature: -20 °C - 60 °C
Process pressure: 1.6 MPa
Precision: 2.5 %
... electromagnetic flow meter measures conductive liquid flow using an insertion probe suitable for large-diameter pipelines. The design supports hot tapping and pressurized installation, allowing installation ...
Process temperature: -40 °C - 60 °C
Process pressure: 4, 1.6, 1, 0.6 MPa
Precision: 0.2, 0.5 %
... cumulative flow during power-off.
Precision: 0.25, 0.4 %
Repeatibility: 0.5 %
... various sensor parameters, anticipating possible problems. The battery converter with integrated modem MV255, flow meters, energy meters, ...
Process temperature: 10 °C - 45 °C
Process pressure: -1 bar - 20 bar
Precision: 2.5 %
... inputs / 5 outputs
Volumetric flow rate: 0 l/min - 20 l/min
... The new mass flow meters and mass flow controllers from Angst+Pfister Sensors and Power are based on the latest generation of MEMS sensor elements. In addition to the outstanding accuracy and repeatability, ...
Process temperature: -40 °C - 85 °C
Precision: 1 %
Repeatibility: 0.1 %
... angle measurement - Optional (RQ-30a): analogue outputs from 4 to 20 mA FIELDS OF APPLICATION The RQ-30 enables discharge measuerment for rivers, streams, open channels and canals for which continuous ...
SOMMER Messtechnik GmbH
Process temperature: -35 °C - 60 °C
Precision: 1 %
Repeatibility: 0.1 %
... non-contact measuring, maintenance free and flood-proof - No structural work is necessary in the water - Recognition of flow direction and hysteresis effects - Measurement in tidal waters - Measurement in backwater situations - ...
SOMMER Messtechnik GmbH
Process temperature: -40 °C - 85 °C
Precision: 1 %
... options, it is the ideal choice for flow measurements in manholes of facilities and sewers. FEATURES AND ADVANTAGES Non-contact measurement, maintenance-free system Calculation of discharge by continuous measurement ...
SOMMER Messtechnik GmbH
Process temperature: -18 °C - 60 °C
Process pressure: 500 psi
... Features flow monitoring with an additional output parameter for temperature. The transmitter can be configured to provide a solid state output with changes in flow and temperature. ...
Volumetric flow rate: 4 l/h - 15,000 l/h
Process temperature: -30 °C - 100 °C
Precision: 5, 2 %
... temperature: PVC: 0~40℃; PP: 0~60℃; PVDF: -30~100℃ Adjustable micro switch: 1 adjustable alarm contact Load: 5A/125VAC, 5A/250VAC, 2A/30VDC Hysteresis: ±10% F.S (Dead Band) Electric transmitter: Analog ...
Volumetric flow rate: 30 l/h - 120,000 l/h
Process temperature: -50 °C - 400 °C
... 30VDC); Adjustable Reed alarm switch available (form A bistable type, N.O type); Adjustable Inductive alarm switch available; 4~20mA (2-wires) analog output available LCD Display: -Totalizer ...
Volumetric flow rate: 0 m³/h - 244,290.2 m³/h
Process temperature: -20 °C - 120 °C
Process pressure: 1.6, 1, 0.6 MPa
... electromagnetic flowmeter is used to measure the volume flow of conductive liquids and slurries in closed pipes. The measuring flow rate is not affected by density, viscosity, temperature and pressure ...
Volumetric flow rate: 1.6 m³/h - 3,125 m³/h
Process temperature: -40 °C - 70 °C
Process pressure: 1 bar - 10 bar
... documentation. EPD Electromagnetic Flow Meter, Water Flow Meter (OIML) The working principle of the electromagnetic flow meter is based on the ...
... measuring points • Combined with transmitters of DA2000er series: • Large analog display (270 °) – Scale length 250 mm • Scale in m³ / h • Different limit indicator • Analog outputs ...
Volumetric flow rate: 0 l/min - 300 l/min
Process temperature: -10 °C - 50 °C
Process pressure: 0.2 bar - 2 bar
... Built upon proven TSI flow sensor technology, the NEW 5000 Series Flow Multi- Meter redefines what a flow meter can do for you. This all-in-one gas mass flow ...
Volumetric flow rate: 0.1 l/min - 100 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 10, 64, 100 bar
... The High Performance MFM / MFC That Adapts To Your Process EL- FLOW® Prestige, the latest generation thermal mass flow meters and controllers for gases, represents a truly ground-breaking ...
Bronkhorst
Volumetric flow rate: 0.1 l/min - 1,670 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 400, 200, 100, 64 bar
... EL- FLOW® Select series Mass Flow Meters/Controllers are thermal mass flow meters of modular construction with a ‘laboratory style’ pc-board housing. Control valves can ...
Bronkhorst
Volumetric flow rate: 0.1 l/min - 50 l/min
Process temperature: -10 °C - 50 °C
Process pressure: 1,000, 1,500 psi
... applications. The base blocks of the Mass Flow Meters and Controllers have 1/4" face seal male (VCR) connections. Metal Sealed Mass Flow Meter/Controller with fieldbus interface Todays ...
Bronkhorst
Volumetric flow rate: 0.63 ft³/min - 120 ft³/min
... CentriFlow Meter from Eastern Instruments is a Solid Particle Mass Flow Meter that is durable, accurate, maintenance-free, compact, and cost-effective. It is unique and positioned to replace weigh belts, ...
Eastern Instruments
Mass flow rate: 2 lb/h - 200 lb/h
Volumetric flow rate: 1.69 ft³/min - 90 ft³/min
... measuring less expensive products, flow meter cost can be a determining factor in the selection of a flow meter. Unfortunately, extremely accurate flow meters ...
Eastern Instruments
Mass flow rate: 100 lb/h - 1,000,000 lb/h
Volumetric flow rate: 0.1 ft³/min - 156.3 ft³/min
Repeatibility: 0.1 %
... depending on your process. The CentriFlow® Type I Meter, just as all CentriFlow® brand meters, is a mass flow meter designed for measuring bulk solids continuously within a process. ...
Eastern Instruments
Volumetric flow rate: 0 m³/h - 19.8 m³/h
Process temperature: 0 °C - 90 °C
Precision: 2 %
... wiring recommended
- RS485
- Selectable current outputs: 4–20 mA, 0–20 mA, 0–24 mA
- Pulse output with selectable NPN or PNP modes
- *Current output
XY-TEK
Volumetric flow rate: 0 l/min - 400 l/min
Process temperature: 0 °C - 60 °C
Precision: 2 %
... detection of air bubbles, bidirectional
flow measurement, volume dosing and
flow switching without external circuitry.
Compare to CPD series clamp on
flow sensors, the CS series
flow ...
XY-TEK
Volumetric flow rate: 0 l/min - 150 l/min
Process temperature: 0 °C - 90 °C
Precision: 1 %
... Product overview
The TPK series inline ultrasonic
flow sensors /
flow
meters feature an integrated design with built-in electronics for direct
flow-rate measurement.
The ...
XY-TEK
Process temperature: -30 °C - 160 °C
Precision: 1 %
... to +160 °C (depending on transducer)
Flow-velocity range — 0 to ±7 m/s
Turbidity — ≤10000 ppm (with limited bubbles)
Analog
output — One 4-20 mA
output
Pulse
output ...
Process temperature: -40 °C - 80 °C
Precision: 0.5 %
Repeatibility: 0.15 %
... range
Repeatability: 0.15%
Linearity: ±0.5%
Pipe size: DN25 to DN5000
Analog
output: 4–20 mA, 750 Ω max load
Pulse
output: 0–9999 Hz, OCT
Relay
output: SPST, 1 Hz max
Communication: ...