- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- RS485 flow meter
RS485 flow meters
Process temperature: -30 °C - 160 °C
... ecnomical digital plastic residential water flow meter High flow accuracy Up to 1 % Suitable diameter Choose different types of sensors, you can realize the diameters of DN15~DN6000mm tube measurement ...
Xian Kacise Optronics Co., Ltd.
Process temperature: -10 °C - 60 °C
Precision: 2 %
Repeatibility: 0.2 %
... Interface RS 485(standard), FUJI protocol and MODBUS Protocol Power Supply - 10~36VDC WIFI Frequency range: 2.412~2.484GHz Transmitted power: 802.11b 16±2 dBm; 13±2 dBm; 14±2 dBm Theoretically, the transmission ...
Gentos
Mass flow rate: 0 kg/h - 860,000 kg/h
Process temperature: -50 °C - 205 °C
Precision: 0.4, 0.25, 0.15, 0.1 %
... Industrial Equipment/Parts, Coriolis Mass Flowmenters, Flow Measurements Products CoriolisMaster FCB100 series of compact system integration flowmeters feature low pressure drop, high flow ...
Shanghai Powerbuilder Automation Technology Co. Ltd
Process temperature: -200 °C - 300 °C
Process pressure: 250 bar
Precision: 0.1, 0.2, 0.5 %
... Once there is flow passing through the pipes, Coriolis force will give rise to deflection (phase shift) on the vibration of two pipes and the deflection of vibration is directly proportional to the mass flow of fluid. ...
Shanghai Yinuo Instrument Co., Ltd
Process temperature: -40 °C - 350 °C
Process pressure: 1.6 MPa - 4 MPa
Precision: 1, 1.5 %
... series Vortex Flow Meter can be used to detect and measure the flow of all kinds of gas, fluid and steam. 1% accuracy stainless steel steam gas liquid fluid vortex flow meter,China ...
Process temperature: 0 °C - 50 °C
Process pressure: 0.45 MPa
Precision: 1, 0.35 %
... and +14V-+28V single–end power supply; digital or analog signal input and output; SEMI standard mechanical dimensions; and RS- 485 or DeviceNet communications module. 5. Miscellaneous Functions Powerful customer ...
Beijing Sevenstar Flow Co., Ltd.
Volumetric flow rate: 0 ft³/s - 16 ft³/s
Process temperature: -40 °C - 80 °C
Precision: 1 %
... and also the clear, user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly and yearly totalized flow. Parallel operation of positive, negative and net flow ...
Soway Tech Limited
... CDI 5400 flowmeters make localized metering of air usage a practical way to manage a compressed-air system. Thermal-dispersion mass- flow technology gives the meter sensitivity to low leakage flows, ...
Process temperature: 32 °F - 150 °F
Process pressure: 5 psi - 80 psi
Precision: 4 %
... FURNACEMETER™ FLOW METER DIFFERENTIAL PRESSURE FLOW METER The FurnaceMeter™ represents a full range of precision flow measurement instruments utilizing our proprietary ...
United Process Controls GmbH
Volumetric flow rate: 0 m³/h - 205,258 m³/h
Process temperature: 180, 80 °C
Precision: 0.2, 0.3, 0.5 %
... 2. RS - 485 communication: the sensor needs to communicate with other equipment. The RS - 485 communication function is required, 3. If you need other functions, please call to customize; Application ...
Process temperature: -70 °C - 380 °C
Precision: 1 %
... interface of the large graphical display is easy to use even by inexperienced users. With the new quick setup option, your flow measurement can be set up in less than a minute. Online help-texts make the use of the printed manual unnecessary ...
systec Controls
Process temperature: 5 °C - 50 °C
Precision: 1.5, 1 %
... factor) ■ Flow range:10SCCM~500SLM Easy operation with display. ・Instant and totalized flow indication. ・Change of gas type. ・Conversion factor setting. ・Upper or lower alarm settintg. ・Change of the calibration ...
Process temperature: -30 °C - 80 °C
... The affordable consumption counter Flowgas TMS 300 works according to the proven calorimetric measuring principle. A heated sensor is cooled by the gas flowing around him. The flow-dependent cooling is utilized as a measuring ...
ACS Control-System GmbH
Volumetric flow rate: 0.3 m³/s - 10 m³/s
Process temperature: -20 °C - 60 °C
Process pressure: 600,000, 1,600,000, 1,000,000 Pa
... 1.Separated type magnetic flow meter 2.Color customization 3.GPRS intelligent 4.irrigation water、feed water、well water、cooling water 5.Meet your requirements GMF100 intelligent electromagnetic flow ...
Xi'an Gavin Electronic Technology Co. Ltd.
... modern and precise flow meter with internal data logging. Equipped with two analogue inputs and two PULS inputs, can measure flow and other values, such as temperature and humidity. In addition FP4 has ...
Volumetric flow rate: 0 l/min - 120 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 7 bar
... Flowmax 400i is a flow meter calculating the volume flow of liquids. Based on the ultrasonic technology Flowmax is able to measure conductive and non-conductive liquids contactfree. Flowmax has no moving ...
Volumetric flow rate: 0 m³/h - 7.9 m³/h
Process temperature: 0 °C - 90 °C
Process pressure: 16 bar
... in the meter reading moment supply low voltage. Meter reading zero error. ● Communication distance between meter and meter reading device: ≤1000m ● Intelligent electronic device in ...
Process temperature: -20 °C - 60 °C
Process pressure: 0 MPa - 26 MPa
Repeatibility: 0.1 %
... conditions into account. It has effectively solved the influence on the metering precision caused by flow distortions( such as turbulent flow, swirl flow, pulsing flow etc). CL-1-4S ...
Jiangsu Flowna Intelligent Technology Co. Ltd
Process temperature: -40 °C - 350 °C
... Features and Benefits of Coriolis Flow Meter Double U or double C type flow pipe design is better for measuring accuracy. Provides integrated Mass Flow, Volume ...
Process temperature: -20 °C - 80 °C
Process pressure: 1.6 MPa
Precision: 1.5 %
... Insertion type electromagnetic flow meter is a type of electromagnetic flow meter has been used throughout industries for more than 50years. Insertion type electromagnetic flow ...
Q&T Instruments
Process temperature: -40 °C - 350 °C
Process pressure: -1 bar - 63 bar
Precision: 1, 0.75 %
... manufacturers. Find vortex flow meter firms that can design, construct, and produce vortex flow meters according to your needs. Then, using our simple request for quote form, contact ...
COMATE
Volumetric flow rate: 0.1 m³/h - 350 m³/h
... Electromagnetic Flow Meter Electronic Part consists of head type Flow Indicator which contains Microprocessor Controller chip mounted on the electronic circuit. It has the LCD display, ...
Process Control Devices
Process temperature: -20 °C - 60 °C
Process pressure: 0.25 bar - 4 bar
... companies for remote copying, monitoring, and control of industrial and commercial gas meter users, and to perform statistical analysis of gas meter gas consumption and meter status. The system not only ...
HANGZHOU INNOVER TECHNOLOGY CO., LTD.
Process temperature: -30 °C - 160 °C
... anti-interference ability,stable and reliable, low starting flow, no pressure loss; • - Isolated RS 485 interface, between the flowmeter and the secondary meter can be ...
Process temperature: 0 °C - 80 °C
Process pressure: 16 bar
... Overview
M10 is an electromagnetic
flow
meter grooved sensor covering diameters from DN50 to DN150. It provides compact dimensions and light weight to enable precise and repeatable measurement of low and
high ...
Process temperature: -40 °C - 60 °C
Process pressure: 0 psi - 50 psi
... Amazon can be used as a stand-alone unit or sensor with a full suite of communication protocols including SDI-12, MODBUS via RS- 485 or TCP, and 4-20mA. The Amazon requires no special software and is easily configured ...
Precision: 2 %
... easily mounted on the pipe. The flow meter's display provides information on flow velocity, date, and time. In another view, it also displays the volume flow rate for the day, month, ...
Volumetric flow rate: 10.2 m³/h - 6,796 m³/h
Process temperature: -6.67 °C - 48.89 °C
Process pressure: 0 psi - 130 psi
... reduced maintenance
Process temperature: -20 °C - 480 °C
Process pressure: -10,000 Pa - 10,000 Pa
... flue duct. This flowmeter adopts the non-contact measurement method, which can effectively solve the measurement difficulties such as unstable flow field and uneven flow velocity distribution in the ...
... respectively. The gas flow rate in the flue is calculated through the time difference of ultrasonic wave transmission, and the volume flow rate of the flue gas is calculated according to the cross-sectional area of the ...
Volumetric flow rate: 3 m³/h - 3,200 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 200,000 Pa
... supply: Safety Barrier Ui=5V, Li=100mA (main power supply) Internal battery: 3.6V ER26500(backup power supply) Communication: RS- 485 Explosion-proof level: ExibllAT4Gb IP grade: IP65 Applications • Biogas Anaerobic ...
... amplitude and in frequency. Dynamic flow : The rate of flow is deduced from a mathematical analysis combined with a calibration (with real measures). Flow no Flow : The threshold can ...
Volumetric flow rate: 0.2 m³/h - 95,560 m³/h
Process pressure: 1.6, 1, 0.6 MPa
... SMT) are implemented to improve the reliability. Electromagnetic flow meter technical parameters Display: reaches 8element liquid crystal display, current clock to indicate flow data. Two kinds ...
... Ultrasonic Flow Sensor [Features] ● Measurement: Flow rate ● Measuring range: Flow rate: 0~±30m/s; Temperature (for heat meter function): Standard: -30~90℃; High temp. -30~160℃ ● ...
the best suppliers