SUP-LDG Carbon steel body electromagnetic flow meter
Magnetic flowmeters operate under the principle of Faraday's Law of Electromagnetic Induction to measure liquid velocity. Following Faraday's Law, magnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic, and slurries. In order of usage, magnetic flowmeter use in water/wastewater industry, chemical, food and beverage, power, pulp and paper, metals and mining, and pharmaceutical application.
Features
Accuracy: ±0.5%(Flow speed > 1m/s)
Reliably: 0.15%
Electric conductivity: Water: Min. 20μS/cm
Other liquid: Min. 5μS/cm
Flange: ANSI/JIS/DIN DN15…1000
Turndown ratio: 1:100
Product - Electromagnetic flowmeter
Model - SUP-LDG
Diameter nominal - DN15~DN1000
Nominal pressure
- DN10 - DN80, PN<4.0MPa
DN100 - DN150, PN<1.6MPa
DN200 – DN1000, PN<1.0MPa
DN1200 – DN2000, PN<0.6MPa
Accuracy - ±0.5%,±2mm/s(flowrate<1m/s)
Repetitiveness - 0.15%
Liner material - PFA, F46, Neoprene, PTFE, FEP
Electrode material - Stainless steel SUS316, Hastelloy C, Titanium,
Tantalum, Platinum-iridium
Medium temperature - Integral type: -10℃~80℃
Split type: -25℃~180℃
Power supply - 100-240VAC,50/60Hz / 22VDC—26VDC
Electrical conductivity - Water 20μS/cm other medium 5μS/cm
Ingress protection - IP65, IP68(optional)
Product standard - JB/T 9248-2015
Measuring principle
Mag meter works based on Faraday's law, and measure conductive medium with conductivity more than 5 μs/cm and flow range from 0.2 to 15 m/s.