Primary current: 10,000 A
VDC: 250, 500, 750, 1,000 V
Rating: 1 A - 63 A
DC Circuit Breaker - Miniature Circuit Breakers for DC and Solar Generation The JB is a DC circuit breaker dedicated to multi string ...
Primary current: 40,000 A
VAC: 230, 400 V
Features: Status indication. MCB specially designed for Surge Arrester. It can cut the leakage current to 3A. Therefore prevent possible fire hazzard caused by degenerated SPD. Special MCB designed to protect the SPD.
Primary current: 5,000 A
VAC: 230 V - 275 V
Product Features: ● High surge current resistance. ● Low cutting current, less than 3A
Primary current: 1,250, 630 A
VAC: 12, 24, 36 kV
... Good pollution resistance. Description: ZW32-12/24 model outdoor AC vacuum circuit breaker is used to make and break load current, overload current and short-circuit current in ...
zhejiang Pomanique Electric Co.,Ltd
Primary current: 1,250, 1,600, 2,000 A
VAC: 36 kV
... outdoor high-voltage vacuum circuit breaker is a kind of outdoor high-voltage switchgear under three-phase AC 50Hz, 36kv rated voltage and below. It can be used to switch on and off the loading, overloading ...
zhejiang Pomanique Electric Co.,Ltd
Primary current: 1,250, 1,600, 2,000, 2,500 A
VAC: 40.5 kV
... voltage indoor vacuum circuit-breaker is used for switchgear KYN61-40.5(Z), it is most new type of power supply and distribution equipment. This product is accordance with GB1984-2003 stand. This series include: Vacuum ...
zhejiang Pomanique Electric Co.,Ltd
Primary current: 1 A - 40 A
VAC: 250 V
VDC: 80 V
Circuit Breaker-B1 Series B1 series product is a hydraulic electromagnetic circuit breaker which our company design and develop by adopting international advanced technology.The ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 50 A
VAC: 120 V - 250 V
VDC: 65 V - 80 V
Circuit Breaker-B2 B2 series product is a hydraulic electromagnetic circuit breaker which our company design and develop by adopting international advanced technology.The ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 100 A
VAC: 480, 277 V
VDC: 80 V
Circuit breaker – B3 B3 series product is a hydraulic electromagnetic circuit breaker which our company design and develop by adopting international advanced technology.The ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
VAC: 660, 690 V
... the mark The circuit breaker complies with the requirements of the standards GB140482″Low voltage switchgear and controlgear-Part2:Low voltage circuit –breakers and ...
Zhejiang Geya Electrical Co., Ltd
Primary current: 630 A
VAC: 12 kV
The switches are designed for normal operating conditions acc. to EN 62271¬1, Class "Minus 5 Indoor”. A proper functioning is also guaranteed up to temperatures of up to ¬15°C. The maximum value of the ambient temperature is 40°C; the ...
VAC: 230 V
Rating: 2 A - 32 A
DIGITAL ELECTRIC
Primary current: 2 A - 125 A
VAC: 12 V - 400 V
Rating: 1 A - 63 A
DIGITAL ELECTRIC
Primary current: 15,000, 20,000 A
VAC: 320 V
DIGITAL ELECTRIC
Primary current: 0.5 A
VAC: 277, 480 V
... the toggle in ON or OFF position Typical Applications - Branch Circuit Protection • Convenience receptacle circuits (internal/external) • Motor control circuits • Load circuits ...
Primary current: 25 A
VAC: 230 V
Residual current circuit-breakers (RCCBs) are components for implementing protective measure "Automatic switch-off of power supply" as per VDE 0100 part 410 or corresponding international installation ...
Doepke Schaltgeräte GmbH
Primary current: 630 A - 2,000 A
VAC: 15 kV
The Hawker Siddeley Switchgear Ltd offers local original equipment manufacturers (OEM's) and panel builders the opportunity to manufacture the switchgear solutions under license whilst meeting the stringent design and quality standards. ...
Primary current: 15, 40, 45 A
VDC: 10 V - 30 V
Power module with PROFINET interface for supplying the CAPAROC circuit breaker system with 12 or 24 V DC. Additional system interface for communication with the power supply. For DIN rail installation ...
Primary current: 16 A
VAC: 250 V
VDC: 72 V
Thermal miniature circuit breaker, can be plugged into PT 10-FSI/C Push-in fuse terminal block. Type - Male Product type - Thermal device circuit breakers Number ...
Primary current: 0.02 A - 50 A
VAC: 125 V - 277 V
VDC: 80 V
... harsh environment applications. Adding to the breaker’s safety features are options for the exclusive Rockerguard and/or push-to-reset bezels for rocker actuated configurations. This up to 50 amp breaker ...
Carling Technologies
Primary current: 5 A - 150 A
VDC: 12 V - 48 V
... Breakers (low profile) Manual Reset ATC Circuit Breakers Series 22X Circuit Breakers Auto, modified and manual reset ATC circuit breakers. Series ...
Primary current: 4,000 A
VAC: 12 kV
... up to 4000A. The circuit breaker conforms to GB 1984-2014 "High Voltage AC Circuit Breaker", JB/T 3855-2008 "3.6~40.5kV Indoor AC High Voltage Vacuum Circuit ...
VAC: 12 kV
CKWB-12/T630-20 outdoor AC high voltage vacuum circuit breaker is an outdoor power distribution equipment with vacuum bubble arc extinguishing SF6 gas insulation, rated voltage 12kV, three-phase AC 50Hz. ...
VAC: 12 kV
CKWZ-12 outdoor AC high voltage vacuum circuit breaker is a new generation of outdoor vacuum circuit breaker self-developed on the basis of fully absorbing the advanced ...
Primary current: 4,000, 5,000 A
VAC: 550 kV
Siyuan Electric Co., Ltd
Primary current: 2,500 A
VAC: 40.5 V
Live Tank Vacuum Circuit breakers (40.5 kV) Without CT or with integrated CT(Inside or outside installation) ZW39 is a combined apparatus including an vacuum circuit breaker,The ...
Siyuan Electric Co., Ltd
Primary current: 4,000 A
VAC: 40.5 kV
... integrated CT(Inside or outside installation) LW36 is a combined apparatus including an SF6 circuit breaker with self-blast arc extinction technology. The circuit breakers ...
Siyuan Electric Co., Ltd
Primary current: 0.5 A - 125 A
VAC: 230 V - 500 V
VDC: 12 V - 230 V
... offer consists of: circuit breakers, residual current devices and modules, electrical components (motor operators, contacts and releases). Salvavita earth-leakage circuit breakers Protection ...
VDC: 600 V - 800 V
Thermal magnetic circuit breakers 600-800 Vdc circuit breakers for photovoltaic systems. Can be fitted with Btdin contacts and shunt trips
Primary current: 16 A - 160 A
VAC: 220 V - 690 V
VDC: 28 V - 230 V
... Megatiker circuit breakers are the most suitable solution for protection against short circuit and overload in medium and high-power systems of the service and industrial sector. Available ...
Primary current: 1 A
VDC: 24 V
... 3 (emitted interference) CE: Acc. to 2014/30/EU Approvals UL 508, UL 2367, DNV GL Applications Electronic circuit breaker with thermomagnetic characteristic with alarm signal forwarded for ...
Primary current: 6 A - 10 A
VAC: 220 V - 690 V
Rating: 130 A
Primary current: 0.2 A - 63 A
VAC: 440 V
VDC: 110 V
... require circuit protection devices featuring very fast overload sensing and opening capabilities. Designed for those applications requiring higher amperage and voltagehandling capability in a compact design. The GR-series ...
Primary current: 100 A - 700 A
VAC: 277 V
VDC: 138 V
... These components require circuit protection devices featuring very fast overload sensing and opening capabilities. The FR circuit breaker can be used in all Railway applications where ...
Primary current: 0 A - 1,000 A
VAC: 12 kV
ISM/TEL-12-20/1000-XXX Rated voltage, kV: 12 Rated current, A: < 1000 Rated short circuit breaking current, kA: < 20 Rated short time withstand current 4s, kA: < 20 Rated frequency, Hz: 50/60 Pole center distance, ...
TAVRIDA ELECTRIC
Primary current: 800 A
VAC: 24 V
ISM/TEL-24-16/800-XXX Rated voltage, kV: 24 Rated current, A: < 800 Rated short-circuit breaking current, kA: < 16 Rated short-time withstand current 4s, kA: < 16 Rated frequency, Hz: 50/60 Pole center distance, ...
TAVRIDA ELECTRIC
Withdrawable Circuit Breaker (ISMD) The ISMD is the withdrawable version of our ISM. It is ready to use in a wide range of draw-out type switchgear and covers the ratings and pole center distances of our ISM.
TAVRIDA ELECTRIC
Primary current: 160 A
EQUES®CrossBoard. circuit breakers up to 160 A mounted on the CrossBoard®. Adapter, 90 mm wide, to accept circuit breakers of different manufacturers. This combination ...
Wöhner
MKS1-KES Box for MKS1 model motor circuit breakers Signal option Emergency stop button option
EMAS
Primary current: 25 A - 1,600 A
VAC: 750 V
Moulded Case Circuit Breakers are produced according to IEC /EN 60947-2 and CE standards and used for protecting the circuits which have different characteristics like cable, motors, ...
SIGMA ELEKTRIK
Primary current: 2,500 A - 100,000 A
... fuse-free circuit breaker (and power-leakage circuit breaker) (50-1600AF/2.5kA-100kA), offering basic electricity protection for commercial or industrial power-distribution ...
TECO ELECTRIC & MACHINERY Co., Ltd.
Primary current: 15 A - 800 A
VAC: 230 V - 500 V
VDC: 125 V - 250 V
Regarding IEC standard for handle? ON/OFF indication, our products from 600A and above Frame Sizes have been marked base color as red for ON and green for OFF. After tripping, our handle position is in the middle and showes half red and ...
TECO ELECTRIC & MACHINERY Co., Ltd.
Primary current: 15 A - 800 A
VAC: 230 V - 500 V
VDC: 125 V - 250 V
‧Regarding IEC standard for handles ON/OFF indication, our products from 400A and above Frame Sizes have been marked base color as red for ON and green for OFF. After tripping, our handle position is in the middle and showes half red ...
TECO ELECTRIC & MACHINERY Co., Ltd.
Primary current: 400 A - 3,150 A
VAC: 0.03 kV
VDC: 110, 220, 24, 48 V
... power plants, chemical/steel plants and construction facilities. It is a new-conceptual circuit breaker with short arc time and interruption time due to short-circuits and ground failure, ...
VitzroEM Co., Ltd.
Primary current: 1,250, 3,150, 1,200, 2,000 A
VAC: 36, 38, 12, 28.5 kV
VDC: 110, 220, 24, 48 V
... power plants, chemical/steel plants and construction facilities. It is a new-conceptual circuit breaker with short arc time and interruption time due to short-circuits and ground failure, ...
VitzroEM Co., Ltd.
Primary current: 600, 1,200, 2,000 A
VAC: 28.5 kV
VDC: 24, 125 V
... power plants, chemical/steel plants and construction facilities. It is a new-conceptual circuit breaker with short arc time and interruption time due to short-circuits and ground failure, ...
VitzroEM Co., Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining