... protection. You could either select a higher-cost transformer switch with advanced protection capabilities, like a circuit-switcher or circuit breaker, or you could choose a lower-cost device with limited ...
Primary current: 20 A - 1,600 A
VAC: 0 V - 1,100 V
VDC: 900 V
... TemBreak 2 is the Ultimate Safety Breaker. It has specifications which exceed international standards for safety. Direct opening action - recommended by IEC standards for machinery safety - is a feature of most models. A unique safety ...
Terasaki (Europe) Circuit Breaker
Primary current: 6 A
VAC: 230 V
... Description Miniature circuit breakers series ETIMAT 6 are high quality devices, produced in EU, with following technical characteristics: Rated short- circuit capacity: 6.000 A Number of poles: 1p, 1p+N, ...
ETI
Primary current: 10,000 A - 100,000 A
VAC: 400 V
Rating: 0.3 A - 100 A
... •Type of protection: Magnetic and thermal •Type of control: Push button •Certified UL Type E: No •Order code - SM1P0400 •Weight [g] - 295 •Qty. per package - 10 •Multiple qty. of packs per order - 10 •Package dimensions [mm] - 080X047X098 •Volume ...
LOVATO ELECTRIC
Primary current: 40 A
VDC: 24 V
... temperature ‑25° C ... +70° C Protection index IP 20 Efficiency: typ. 99 % Advantages Selective immediate switch off of defective circuits in the event of critical supply voltage Sequential and load‑dependent switching‑on of channels Comprehensive ...
Block Transformatoren-Elektronik
Primary current: 1 A - 63 A
VAC: 240, 415 V
... overload and short circuit protection, applies to a circuit of AC 50Hz,rated voltage 230/400V, rated current up to 63A. Usually it functions as un frequently switching. In addition, it can be also used as an isolator ...
ZHEJIANG VEKON TECHNOLOGY CO.,LTD
Primary current: 0.05 A - 10 A
VAC: 240 V
VDC: 48 V
... Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934) integral type. Approved to CBE standard EN 60934 (IEC 60934). For higher current ...
E-T-A
Primary current: 1 A - 50 A
... Circuit breakers are the ‘safety stop’ signs of your onboard electrical system, they secure the electrical circuit against overload or short circuits. For equipment that is connected ...
Primary current: 6, 301, 250 A
VAC: 12 kV
... Overview The ZW32-12 outdoor medium voltage vacuum circuit breaker has a rated voltage of 12 KV. It is a kind of three phase outdoor distribution facility for 50 Hz Power. Features The features include great stability ...
Beijing SOJO Electric Co., Ltd
The over-view below shows the full range of SCAMEs distribution assemblies. With their compact size, robust construction and protection degree from IP44 to IP66, they meet the most varied power distribution requirements in factories, workshops, agriculture, ...
... MKS1-KES Box for MKS1 model motor circuit breakers Signal option Emergency stop button option ...
EMAS
Primary current: 0 A - 25 A
VDC: 9 V - 55 V
... The Power Rider 25A is an advanced electronic (solid state) circuit breaker designed to protect and manage power systems efficiently. It provides precise control with three layers of protection, real-time monitoring, ...
Redler Technologies LTD
Primary current: 2,300 A
VAC: 1,800, 3,600 V
VDC: 4,800 V
... The UR26-64 is a trip-free DC high-speed current limiting air circuit- breaker, single pole unit, bi-directional, with electromagnetic blowout, direct instantaneous over-current release, natural air-cooling and electrical ...
Secheron
Primary current: 1,250, 630 A
VAC: 12, 24, 36 kV
... Good pollution resistance. Description: ZW32-12/24 model outdoor AC vacuum circuit breaker is used to make and break load current, overload current and short- circuit current in 12/24kV, 50/60Hz ...
Pomanique Electric
VAC: 35 kV
... compensation capacitor, etc., which can limit the atmospheric over-voltage and the operating over-voltage caused by each vacuum circuit breaker, and the over-voltage relative to ground and phase to phase can cause reliable ...
Primary current: 0.5 A
VAC: 277, 480 V
... the toggle in ON or OFF position Typical Applications - Branch Circuit Protection • Convenience receptacle circuits (internal/external) • Motor control circuits • Load circuits ...
Primary current: 100 A - 700 A
VAC: 277 V
VDC: 138 V
... These components require circuit protection devices featuring very fast overload sensing and opening capabilities. The FR circuit breaker can be used in all Railway applications where protection against ...
VDC: 120 V
... Solar Panel level rapid shutdown BFS series is developed for solar roof and building safety. UL listed and compliant with NEC2017 A cost-efficiency and purely rapid shutdown solution to meet NEC2017 690.12 In cases of fire in buildings with solar ...
Zhejiang Benyi Electrical Co.,ltd.
Primary current: 0.16 A - 32 A
... MOTOR-PROTECTIVE CIRCUIT BREAKERS SERIES “ESM” - “ESB” When protecting or controlling three phases and single phase motors up to 11kW, it can be used as power switch. The thermal release has a wide setting range which ...
Primary current: 0.5 A - 100 A
... Single Pole AC fitted with Plug-in Terminals Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial Mounting Approvals: • IEC60947-2 • UL489 • GB140482 • EAC • CE Ratings 90 A to 100 ...
CBI-electric: low voltage
Primary current: 2 A - 63 A
VAC: 230, 240, 415, 400 V
VDC: 48 V
... WERNER'S 50 series miniature circuit breakers provide the customer a comprehensive efficient, reliable protection of equipments, cables and installations in buildings for over load and short circuit faults. Features ...
Primary current: 630 A - 4,000 A
VAC: 12, 17.5, 24 kV
... indoor AC High voltage circuit breaker,DL/T403 Specification of 12-40.5Kv indoor High voltage vacuum circuit breaker for order as well as IEC60694. This circuit breaker ...
Primary current: 10, 63 A
VDC: 1,000 V
... The circuit breaker has the functions of short circuit protection, overload protection, control, isolation and so on. It is suitable for terminal power distribution, civil construction, energy control, ...
Aswich Electrical Co., Ltd
Primary current: 160, 200, 225, 250 A
VAC: 380, 415 V
Federal Elektrik
Primary current: 600 A - 20,000 A
VAC: 12 kV - 24 kV
... Vacuum Circuit Breaker (VCB) General Type: Fixed and Draw-out type Specifications: 12-24kV, 600-2000A, 12-16kA (Asym, rms) Life cycle: Electrical: 10000 operations (for rated load switching) Mechanical: 10000 operations ...
Primary current: 500 A - 630 A
VAC: 690 V
... Ui:690V Current:500.600.630A Pole: 3P 4P Breaking Capacity: Icu: 220V/ 35kA (sym) 380V/ 25kA (sym) 440V/ 22kA (sym) Ics = 50% Icu Accessories: AL.AUX.SHT.UVT.EH630N(IP30.IP52).TC630N. ...
Shihlin Electric & Engineering Corporation
Primary current: 63 A
... leakage circuit breaker is used for the protection, against electrical leakage in the circuit of 50/60Hz, rated voltage 1- phase 240V, 3 phase - 400V, rated current up to 63A.When somebody gets an electrical ...
Primary current: 25,000 A - 63,000 A
VAC: 0 V - 245,000 V
... CSV vertical interrupter ("candlestick") circuit switcher expands Southern States circuit switcher line to fit shrinking substation space requirements. The CSV brings circuit breaker ...
Primary current: 3,000, 1,500 A
VDC: 1,800, 900 V
... and capability to withstand shocks and vibrations. The IR3000V Series is a range of single pole, air, high speed circuit breakers for DC applications with air breaking, available in two voltage ratings of 900 and ...
Microelettrica
Primary current: 2,500 A - 100,000 A
... fuse-free circuit breaker (and power-leakage circuit breaker) (50-1600AF/2.5kA-100kA), offering basic electricity protection for commercial or industrial power-distribution loops for ...
TECO ELECTRIC & MACHINERY Co., Ltd.
Primary current: 630 A - 2,000 A
VAC: 15 kV
The Hawker Siddeley Switchgear Ltd offers local original equipment manufacturers (OEM's) and panel builders the opportunity to manufacture the switchgear solutions under license whilst meeting the stringent design and quality standards. Utilizing the ...
Primary current: 0 A - 44,000 A
VAC: 3 kV
... High-Current Disconnector "welded type" High-Current Disconnector for the interchange "copper to aluminium" Rated Voltage: up to 3 kV Rated Current up to 180 kA Special versions with up to 440 kA rated current. Welded type for aluminium busbar Perfect ...
Primary current: 630, 1,250 A
VAC: 12, 24, 17.5 kV
VDC: 36 kV
... energy type with closing and opening release that are fit for local and remote applications. The remote control of the circuit- breaker is accessible by the operations of special electrical extras like geared motor, shunt ...
SAREL
Primary current: 25 A - 1,600 A
VAC: 750 V
... Moulded Case Circuit Breakers are produced according to IEC /EN 60947-2 and CE standards and used for protecting the circuits which have different characteristics like cable, motors, lighting, generators ...
SIGMA ELEKTRIK
Primary current: 3,000, 4,000, 6,000 A
VDC: 750 V - 1,800 V
... Entec's DC High-Speed Circuit Breaker (HSCB) symbolizes our advanced technology in DC interrupting. Entec's HSCB(EDB-09 and EDB-18) is used to manage DC Power Feeding line and interrupts the fault current. EDB-09 has ...
Primary current: 1 A - 63 A
VAC: 110 V - 480 V
... Function Protection of circuits against short- circuit currents, Protection of circuits against overload currents, Switch, Isolation, Circuit-breakers are used in domestic installation, ...
Primary current: 0 A - 0.05 A
VDC: 0 V - 10 V
... Our most popular alarm trip, thousands in operation Universal plant standard, no need to stock different alarm trips Pushbuttons- and PC-programmable with FREE software and cable Customizable display shows process status/diagnostics 20-bit input resolution ...
Moore Industries
Primary current: 1,250 A
VAC: 17.5 kV
... Rated short- circuit breaking current - ≤ 31,5 kA Rated short-time withstand current 4s - ≤ 31,5 kA Rated frequency - 50/60 Hz Mechanical endurance - 30 000 CO cycles Temperature range - -40...+55 °C* Weight - ...
TAVRIDA ELECTRIC NORTH AMERICA
Primary current: 6 A - 800 A
VAC: 400, 690 V
... mainly used in the circuit of AC 50/60Hz, rated insulating voltage 690V (630 type is 500V), rated working voltage up to 690V, and rated current from 6A-800A in distribution line for distributing power, protecting line, overload, short- circuit ...
Radin Electric Technology Co., lTD
Primary current: 160 A
... EQUES®CrossBoard. circuit breakers up to 160 A mounted on the CrossBoard®. Adapter, 90 mm wide, to accept circuit breakers of different manufacturers. This combination of circuit ...
Wöhner
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.