Primary current: 630 A - 6,300 A
VAC: 220, 415 V
Rating: 800 A - 1,000 A
... Future Ready ! MasterPact MTZ is a comprehensive range of air circuit breakers, to protect from damage caused by overloads, short- circuits or insulation faults. MasterPact MTZ embeds advanced digital ...
Schneider Electric
Primary current: 630 A - 6,300 A
VAC: 1,150 V
... fail-safe power distribution. Discover the new SENTRON 3WA air circuit breakers – they let makers simply achieve what they want to achieve. Makers watch out: the new SENTRON 3WA air ...
Siemens Low-voltage – Power distribution
Primary current: 3,150 A
VAC: 72.5, 100, 123, 145 kV
... spring mechanism for the 3 phases) operated circuit- breaker GE’s live tank circuit- breakers provide a high level of reliability, even under extreme conditions and ...
Primary current: 4,000 A
... in the SF6 gas compartment in order to reduce external environmental influences. The DCB (Disconnecting Circuit Breaker) is used as a circuit breaker and also as a disconnector – two ...
Primary current: 6,900, 7,150 A
VAC: 24 kV
... System type generator circuit- breaker (GCB) with innovative built-in monitoring The HVS-63S GCB with SF6 interrupting technology for short- circuit currents up to 63 kA and rated currents up to 7,150 ...
Primary current: 1,000 A - 6,300 A
VAC: 500 V
... Make electrical equipment multi-functional by means of Mitsubishi air circuit breakers that are suitable for protection of the main circuit Air circuit breakers have ...
MITSUBISHI Automation
Primary current: 2 A - 63 A
... Designed for overcurrent and short circuit protection. Eletric current range from 2 to 63 A in versions of single, two, three and four poles. Safety The MDWP, MDW and MDWH miniature circuit ...
WEG Gear Systems GmbH
Primary current: 0.5 A - 30 A
... Electromechanical Circuit Breakers (CB) with several different terminals (FASTON, EN, MIL...) and accessories. ...
Crouzet
Primary current: 0.1 A - 125 A
VAC: 480, 277, 240 V
VDC: 160, 125 V
... The 209, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection in a compact single or multi- pole unit. The unit is ideal for branch circuit ...
Sensata Technologies
Primary current: 0.2 A - 70 A
VAC: 400, 250, 415, 277 V
VDC: 80 V
... . Rail-Mount Magnetic circuit protectors offer the advantages of quick and easy mounting or removal, resulting in efficient and economical wiring while conserving space. These circuit protectors are available in 1, 2, ...
Sensata Technologies
Primary current: 0.02 A - 50 A
VAC: 240, 24 V
VDC: 80 V
... Previously referred to as the 217 family of circuit breakers, the Airpax™ IAG/IUG/CEG/LEG magnetic circuit protectors provide low-cost power switching, reliable circuit protection and ...
Sensata Technologies
... TANM1/TANM2 series moulded case circuit breaker (hereinafter referred to as circuit breaker) is suitable in a circuit with AC 50Hz (or 60Hz), rated operating voltage ...
... LW8-40.5 Outdoor AC High Voltage SF6 Circuit Breaker Category:Components ...
Primary current: 63 A - 250 A
VAC: 80 V - 270 V
Rating: 63, 125, 160, 250 A
... >
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... • IEC 62271, ANSI/IEEE Std C37, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • ...
Dowei Electric
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... • IEC 62271, ANSI C37.04, C37.06, C37.09 • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • ...
Dowei Electric
Primary current: 600 A - 3,000 A
VAC: 4.16 kV - 40.5 kV
VDC: 110 V - 220 V
... • IEC 62271, ANSI/IEEE Std C37, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • ...
Dowei Electric
Primary current: 2 A - 125 A
VAC: 12 V - 400 V
Rating: 1 A - 63 A
... Magneto-thermal circuit breakers allow the circuit to be cut off in the event of overcurrent or a dead short circuit, while surge protectors will act on overvoltages of atmospheric origin. These ...
DIGITAL ELECTRIC
Primary current: 15,000, 20,000 A
VAC: 320 V
DIGITAL ELECTRIC
Primary current: 63 A
VAC: 240 V
DIGITAL ELECTRIC
Primary current: 1 A - 63 A
VAC: 415, 250, 127 V
VDC: 65, 80 V
... series hydraulic-magnetic circuit breaker is a front-mounted circuit breaker. It has up to four poles and can be used for both AC and DC applications. It is a modular ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 63 A
VAC: 240, 250, 415, 120 V
... endure adverse conditions, the B 3 circuit breaker is used in military and railway applications, as well as in renewable energy solutions to protect combiner boxes and battery storage. Features • ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 200 A
VAC: 415, 250, 240 V
VDC: 125, 80 V
... adverse conditions, the B 3 circuit breaker is used in military and railway applications, as well as in renewable energy solutions to protect combiner boxes and battery storage. Features • Poles: ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 40,000, 80,000 A
VAC: 500 V
... MCB specially designed for Surge Arrester. It can cut the leakage current to 3A The color of the visual alarm window indicates the working status of the protection, green (normal) and red (fault). Flame-retardant housing design for ...
Primary current: 20,000, 40,000 A
VAC: 500 V
... MCB specially designed for Surge Arrester. It can cut the leakage current to 3A The color of the visual alarm window indicates the working status of the protection, green (normal) and red (fault). Flame-retardant housing design for ...
Primary current: 80 A - 125 A
VAC: 230 V - 400 V
... Circuit breakers PR121 - PR122 - PR123 - PR124 series 1- to 4- pole circuit breakers, from 80 to 125 A. B and C curves. ...
Primary current: 0.02 A - 50 A
VAC: 125 V - 277 V
VDC: 80 V
... the breaker’s safety features are options for the exclusive Rockerguard and/or push-to-reset bezels for rocker actuated configurations. This up to 50 amp breaker is configurable as one to six poles ...
Carling Technologies
Primary current: 1 A - 63 A
VAC: 240, 415 V
... overload and short circuit protection, applies to a circuit of AC 50Hz,rated voltage 230/400V, rated current up to 63A. Usually it functions as un frequently switching. In addition, it can be also used as an isolator ...
ZHEJIANG VEKON TECHNOLOGY CO.,LTD
Primary current: 1,250, 630 A
VAC: 12, 24, 36 kV
... High level of insulation. 3. Long service life time. 4. Good pollution resistance. Description: ZW32-12/24 model outdoor AC vacuum circuit breaker is used to make and break load current, overload ...
Pomanique Electric
Primary current: 4,000 A
VAC: 123, 145 kV
... compensation loop) LW36 is a combined apparatus including an SF6 live tank circuit breaker with self-blast arc extinction technology.The circuit breakers are available for single or ...
Sieyuan Electric Co., Ltd
Primary current: 125 A - 400 A
VDC: 1,000, 1,250, 1,500 V
... EM 3DP-U series of DC plastic case circuit breakers for photovoltaics—parameters.the battery systems and energy storage systems,with over load protection and short. Product Benefits High Breaking ...
Primary current: 1,250 A
VAC: 17.5 kV
... Rated short- circuit breaking current - ≤ 31,5 kA Rated short-time withstand current 4s - ≤ 31,5 kA Rated frequency - 50/60 Hz Mechanical endurance - 30 000 CO cycles Temperature range - -40...+55 °C* Weight - ...
TAVRIDA ELECTRIC NORTH AMERICA
Primary current: 10,000 A
VAC: 415 V
Rating: 30 A
... UL1077 MCB 3 pole 30A B Curve Pack Size: 16 Specifications • Nema Rating NEMA 1 • Temperature Range °C -25°C to +55°C • Number of Poles 3P • IP Rating IP20 • Tripping Curve ...
IMO Precision Controls Limited
Primary current: 0.25 A - 25 A
... EFD 3 series three pole, magnetothermic breakers are used for command (start - stop) and protection of three-phase motors. Circuit breaker with adjustable magnetothermic ...
Primary current: 1 A - 40 A
... overload and short circuit for all domestic, commercial and any low voltage distribution systems. · Only 18mm for 2P and 36mm for 3P+N/4P · Overloaded and short circuit protection · Rated breaking ...
WENZHOU RENA ELECTRIC CO.,LTD
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group