- Electricity - Electronics >
- Switch and Relay >
- 3-pole circuit breaker
3-pole circuit breakers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 1,000 A - 6,300 A
VAC: 500 V
... Make electrical equipment multi-functional by means of Mitsubishi air circuit breakers that are suitable for protection of the main circuit Air circuit breakers have ...
MITSUBISHI Automation
Primary current: 630 A - 6,300 A
VAC: 220, 415 V
Rating: 800 A - 1,000 A
... Future Ready ! MasterPact MTZ is a comprehensive range of air circuit breakers, to protect from damage caused by overloads, short- circuits or insulation faults. MasterPact MTZ embeds advanced digital ...
Schneider Electric
Primary current: 0.5 A - 30 A
... Electromechanical Circuit Breakers (CB) with several different terminals (FASTON, EN, MIL...) and accessories. ...
Crouzet
Primary current: 40,000 A
VAC: 145 kV
Rating: 30 A
... items)
- 8VM3 Blue GIS: Operates at 72.5 kV; compact modular design; suited for onshore grids, industry, renewables and offshore substations.
- 3AV1 Blue LT Circuit Breaker:
Siemens Energy – Power transmission
Primary current: 0 A - 500,000 A
VAC: 12,000 V
... Overview
Type ZW20-12 outdoor
pole-mounted high-voltage vacuum
circuit
breaker is a 12 kV three-phase AC, 50 Hz outdoor high-voltage switchgear. It is designed to switch load current, overload ...
Sieyuan Electric Co., Ltd
Primary current: 160 A
VAC: 690 V
Rating: 160 A
... Product overview
Moulded-case
circuit
breaker MEGATIKER M
3 250H electronic
3P. Rated current: 160 A, breaking capacity: 70 kA, setting type S10.
Technical features
Brand: ...
BTICINO
Primary current: 630 A - 6,300 A
VAC: 1,150 V
... fail-safe power distribution. Discover the new SENTRON 3WA air circuit breakers – they let makers simply achieve what they want to achieve. Makers watch out: the new SENTRON 3WA air ...
Siemens Low-voltage – Power distribution
Primary current: 6,900, 7,150 A
VAC: 24 kV
... System type generator circuit- breaker (GCB) with innovative built-in monitoring The HVS-63S GCB with SF6 interrupting technology for short- circuit currents up to 63 kA and rated currents up to 7,150 ...
Primary current: 1,250 A - 3,150 A
VAC: 125 kV
... interfaces match existing SF6-filled AC
circuit
breakers for high interchangeability.
Categories
- High-voltage solutions
- Circuit breakers
Main ...
Henan ping high electric co., LTD.
Primary current: 2 A - 63 A
VAC: 230, 400 V
... DZ47-63 MCB is suitable for the distribution circuit of AC 50/60Hz, rated voltage up to 400V, rated current up to 63A, rated short- circuit breaking capacity does not exceed 6000A, as the use of circuit's ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
Primary current: 6 A - 10 A
VAC: 220 V - 690 V
Rating: 130 A
Primary current: 0.1 A - 125 A
VAC: 480, 277, 240 V
VDC: 160, 125 V
... The 209, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection in a compact single or multi- pole unit. The unit is ideal for branch circuit ...
Sensata Technologies
Primary current: 0.2 A - 70 A
VAC: 400, 250, 415, 277 V
VDC: 80 V
... . Rail-Mount Magnetic circuit protectors offer the advantages of quick and easy mounting or removal, resulting in efficient and economical wiring while conserving space. These circuit protectors are available in 1, 2, ...
Sensata Technologies
Primary current: 0.02 A - 50 A
VAC: 240, 24 V
VDC: 80 V
... Previously referred to as the 217 family of circuit breakers, the Airpax™ IAG/IUG/CEG/LEG magnetic circuit protectors provide low-cost power switching, reliable circuit protection and ...
Sensata Technologies
... TANM1/TANM2 series moulded case circuit breaker (hereinafter referred to as circuit breaker) is suitable in a circuit with AC 50Hz (or 60Hz), rated operating voltage ...
... LW8-40.5 Outdoor AC High Voltage SF6 Circuit Breaker Category:Components ...
Primary current: 63 A - 250 A
VAC: 80 V - 270 V
Rating: 63, 125, 160, 250 A
... >
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... Requirements and testing for AC high-voltage
circuit
breakers.
·IEEE C37 Series – North American standards covering ratings, testing, and application.
A live tank
circuit
breaker ...
Dowei Electric
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... 5000m
• High current switching capability, Reliable and Flexible solutions
Dead Tank
Circuit
Breaker (DTC) is a high-voltage outdoor
circuit
breaker in which the interrupter ...
Dowei Electric
Primary current: 600 A - 3,000 A
VAC: 4.16 kV - 40.5 kV
VDC: 110 V - 220 V
... Requirements for AC
circuit
breakers, including many outdoor vacuum
breaker designs.
·IEC 62271-1 – General requirements for high-voltage switchgear and controlgear.
·IEEE C37.04 – Defines ratings ...
Dowei Electric
Primary current: 2 A - 125 A
VAC: 12 V - 400 V
Rating: 1 A - 63 A
... Magneto-thermal circuit breakers allow the circuit to be cut off in the event of overcurrent or a dead short circuit, while surge protectors will act on overvoltages of atmospheric origin. These ...
DIGITAL ELECTRIC
Primary current: 15,000, 20,000 A
VAC: 320 V
DIGITAL ELECTRIC
Primary current: 63 A
VAC: 240 V
DIGITAL ELECTRIC
Primary current: 1 A - 63 A
VAC: 415, 250, 127 V
VDC: 65, 80 V
... series hydraulic-magnetic circuit breaker is a front-mounted circuit breaker. It has up to four poles and can be used for both AC and DC applications. It is a modular ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 63 A
VAC: 240, 250, 415, 120 V
... endure adverse conditions, the B 3 circuit breaker is used in military and railway applications, as well as in renewable energy solutions to protect combiner boxes and battery storage. Features • ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 200 A
VAC: 415, 250, 240 V
VDC: 125, 80 V
... adverse conditions, the B 3 circuit breaker is used in military and railway applications, as well as in renewable energy solutions to protect combiner boxes and battery storage. Features • Poles: ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 40,000, 80,000 A
VAC: 500 V
... MCB specially designed for Surge Arrester. It can cut the leakage current to 3A The color of the visual alarm window indicates the working status of the protection, green (normal) and red (fault). Flame-retardant housing design for ...
Primary current: 20,000, 40,000 A
VAC: 500 V
... MCB specially designed for Surge Arrester. It can cut the leakage current to 3A The color of the visual alarm window indicates the working status of the protection, green (normal) and red (fault). Flame-retardant housing design for ...
Primary current: 400 A - 2,000 A
VAC: 440 V - 690 V
... AX106D, AX108D, AX110D, AX112D, AX116D for frames 630–1600 AF; available in 3 or 4 poles.
Primary current: 80 A - 125 A
VAC: 230 V - 400 V
... Circuit breakers PR121 - PR122 - PR123 - PR124 series 1- to 4- pole circuit breakers, from 80 to 125 A. B and C curves. ...
Primary current: 0.02 A - 50 A
VAC: 125 V - 277 V
VDC: 80 V
... the breaker’s safety features are options for the exclusive Rockerguard and/or push-to-reset bezels for rocker actuated configurations. This up to 50 amp breaker is configurable as one to six poles ...
Carling Technologies
Primary current: 1 A - 63 A
VAC: 240, 415 V
... overload and short circuit protection, applies to a circuit of AC 50Hz,rated voltage 230/400V, rated current up to 63A. Usually it functions as un frequently switching. In addition, it can be also used as an isolator ...
ZHEJIANG VEKON TECHNOLOGY CO.,LTD
Primary current: 1,250, 630 A
VAC: 12, 24, 36 kV
... High level of insulation. 3. Long service life time. 4. Good pollution resistance. Description: ZW32-12/24 model outdoor AC vacuum circuit breaker is used to make and break load current, overload ...
Pomanique Electric
Primary current: 125 A - 400 A
VDC: 1,000, 1,250, 1,500 V
... EM 3DP-U series of DC plastic case circuit breakers for photovoltaics—parameters.the battery systems and energy storage systems,with over load protection and short. Product Benefits High Breaking ...
Primary current: 1,250 A
VAC: 17.5 kV
... Rated short- circuit breaking current - ≤ 31,5 kA Rated short-time withstand current 4s - ≤ 31,5 kA Rated frequency - 50/60 Hz Mechanical endurance - 30 000 CO cycles Temperature range - -40...+55 °C* Weight - ...
TAVRIDA ELECTRIC NORTH AMERICA
Primary current: 10,000 A
VAC: 415 V
Rating: 30 A
... UL1077 MCB 3 pole 30A B Curve Pack Size: 16 Specifications • Nema Rating NEMA 1 • Temperature Range °C -25°C to +55°C • Number of Poles 3P • IP Rating IP20 • Tripping Curve ...
IMO Precision Controls Limited
Primary current: 1 A - 40 A
... overload and short circuit for all domestic, commercial and any low voltage distribution systems. · Only 18mm for 2P and 36mm for 3P+N/4P · Overloaded and short circuit protection · Rated breaking ...
WENZHOU RENA ELECTRIC CO.,LTD
Primary current: 10,000 A
VDC: 250, 500, 750, 1,000 V
Rating: 1 A - 63 A
... DC Circuit Breaker - Miniature Circuit Breakers for DC and Solar Generation The JB is a DC circuit breaker dedicated to multi string photovoltaic installations. This ...
VAC: 230, 400 V
Rating: 1 A - 63 A
... breaking capacity small circuit breaker is mainly used in AC 50Hz/60Hz, rated working voltage 230V/400V, rated current to 63A and below. Normally, it can also be used as an infrequent disconnection and conversion of lines. ...
Zhejiang Geya Electrical Co., Ltd
Primary current: 1 A - 63 A
VAC: 250, 500, 750, 1,000 V
VDC: 0 V - 1,200 V
Anson NKC1-63DC Series PV DC Isolator Switches are mainly be used in PV solar power system, which are applied for DC solar combiner box, controller etc. The Max voltage up to 1200VDC, current up to 63A, with the function of effective disconnection and ...
SHANGHAI ANSON ELECTRIC TECHNOLOGY CO.,LTD
Primary current: 630 A - 4,000 A
VAC: 12 kV
... VAC83 VCB is in a new type indoor switch device, which is mainly used in three-phase AC power system with rated voltage of 12kV, and rated frequency of 50-60Hz. It has the advantages of compact structure, high reliability, small operation ...
Wenzhou Vacem Technology Co., Ltd
Primary current: 6,000 A
VAC: 400 V
Rating: 2 A - 63 A
... - Tripping curve: B, C B - The maximum current release breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect main power supply ...
Elmark
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.