type 2 surge arresterSurge-Trap® STET23 series
Voltage: 120, 230 V
Primary current: 20,000 A
... • Nominal discharge current (8/20μs): 10kA • Combined voltage pulse (1.2/50μs): 6kV • Filter attenuation up to 82dB ( common mode) • Rated current load (IL): 20A • Single phase TT and TNS networks • Visual (LED) ...
Voltage: 230 V
Primary current: 20,000 A
... - Type 2 AC surge protector - RFI filtering - In : 20 kA - Imax : 40 kA - Pluggable module - Remote signaling option - EN 61643-11, CEI 61643-11, UL1449 ed.3 compliance DS40HF Surge Protectors ...
Voltage: 220 V - 240 V
Primary current: 10 A - 10 A
Open circuit voltage: 10 kV - 10 kV
... load current @25°C (IL): 10 A
Voltage: 600, 1,000 V
Primary current: 12,500, 25,000, 60,000 A
... buildings with external lightning protection Available for photovoltaic applications with a generator voltage of up to 1000 V. Available as type 1 and type 2 combined lightning current and surge arresters ...
Voltage: 600 V
Primary current: 12,500, 25,000, 60,000 A
... current and surge arresters as well as type 2 only surge arrester protective devices. Installation instruction: These units must be installed in parallel on the DC networks to be protected ...
Voltage: 1,000, 1,200 V
Primary current: 12,500, 25,000, 60,000 A
... current and surge arresters as well as type 2 only surge arrester protective devices. Installation instruction: These units must be installed in parallel on the DC networks to be protected ...
Voltage: 230, 130, 275, 145 V
Primary current: 10,000, 30,000 A
Open circuit voltage: 700 V
... ITC-BT-23. Double connection in order to facilitate wiring (limited to 63 A). Compact multi-pole protection. Both common and differential protection. Coordinable with protectors of series ATSHOCK, ATSHIELD and ATSUB. Short ...
Aplicaciones Tecnológicas, S.A.
power supply surge protectorSM20(30)M230L205 series
Voltage: 230, 385 V
Primary current: 20,000, 30,000, 40,000, 60,000 A
... Surge protective device module (SPD-M) is an onboard lightning protection module that integrates functions, such as thermal protection, overvoltage protection, and remote signaling, and others. A single ...
Voltage: 5 V - 33 V
Primary current: 10,000 A - 20,000 A
... voltage or surge current blind spots occurring. Thermal protection is provided to reduce the hazards of thermal runaway should there be an inadvertent mains incursion fault. Both common (longitudinal) mode ...
Raycap
Voltage: 120 V
Primary current: 10,000 A
... • Series connection for applications up to 20 A rated current. • With electromagnetic interference (EMI) filter. Common mode attenuation of the filter is up to 82 dB. • Maximum discharge current with an ...
Cirprotec
... communication equipment. By adding a large-capacity lightning protection discharge tube to the serial port signal, the purpose of protecting RS232 equipment is achieved. This product has excellent lightning ...
Wuhan Maiwe Communication Co., Ltd
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group