{{{product.idpText}}}
Trigger voltage: 24 V
... sensors for non- safety applications, such as photoelectric monitoring position or end-of-travelThe safety inputs can monitor:+24V dc solid-state (PNP) outputs in single-channel or dual-channel hookup+24V ...
Trigger voltage: 24 V
... the available outputs of a safety controller and increase the switching current capacity of low voltage safety devices to 6 amps -Models available with three normally open (NO) safety outputs or two ...
Trigger voltage: 24 V
... four hard- relay contact or OSSD output safety devices Available in models for Type 2 and Type 4 applications Offers 24V dc supply voltage with either two solid-state OSSD or 2 normally open ...
Tripping current: 4 A
Trigger voltage: 42, 230, 24, 110 V
... Monitoring of BNS range magnetic safety sensors 1 safety contact, STOP 0 ...
... Our PNOZ X safety relays are proven through their reliability and sturdiness. They are used in a wide range of applications and in the most diverse safety applications. Use one PNOZ X per safety ...
PILZ
Tripping current: 16 A - 40 A
... Use the modular safety relay PNOZpower to monitor E-STOP, safety gates and light barriers. With PNOZpower you can switch currents of up to 16 A AC/ DC per contact. An overall breaking ...
PILZ
... supply voltage U1 - DC Power consumption DC - 4.5 W Inputs Number of inputs - 2 Semiconductor outputs Number of semicond. outputs - 0 Relay outputs Utilisation cat. AC/ DC1 ...
PILZ
... of the safety functions lead to a sustainable reduction in storage costs. Besides safety functions such as emergency stop, protective door, non-equivalent safety sensor, two-hand ...
DOLD
... The first emergency stop module, by DOLD developed in 1988, was called BN 5983 for man-machine protection. Conventional contactor controls have high cost interconnection wiring, but instead of that you can use this product and save a lot of money as ...
DOLD
The LG 5925/900 Series, manufactured by Dold, is a light barrier controller equipped with a prewired rail-mounted module that include a 5 ms sampling time module. This controller offers low maintenance and high performance operation for dangerous closing ...
DOLD
Tripping current: 20 mA
Trigger voltage: 24 V
... ISO 13851. In this way, a high level of protection against tampering is provided. • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting ...
Tripping current: 20 mA
Trigger voltage: 24 V
... start with automatic start or a start button • Monitoring of downstream relays or contactors. • Simultaneity monitoring to monitor safety components over time • Relay start using a monitored start ...
Tripping current: 4, 6 A
Trigger voltage: 24, 250 V
... two-hand switch input. Provide 3 NO instantaneous safety output contacts and 1 NC instantaneous auxiliary output contacts, and provide 2 groups of signal output functional safety relays. Manual ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 24, 240, 250 V
... Supports emergency stop switch, safety door lock, and passive switch inputs Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 24, 240, 250 V
... Supports emergency stop switches, interlock switches, and passive switch inputs Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel ...
Bytorent Technology Co., Ltd.
Trigger voltage: 24 V
... disconnect, switch, or convert voltage - even where space is at a premium. Our product portfolio comprises a diversity of relay and optocoupler modules that use the practical terminal block format. Our analog transformers and temperature ...
... The safety relay / safety switching devices from di-soric make simple integration of individual safety sensors into occupational safety solutions possible. di-soric ...
di-soric
Tripping current: 4, 2 A
... operation with the Mechan range of non-contact safety switches, the SRL-1 is also suitable for use with dual channel Emergency Stop buttons, or safety devices with 2 safety outputs e.g mechanical safety ...
Trigger voltage: 24 V
... Safety Module – Useful to control inputs as safety limit switches, solenoid commanded interlocks, safety magnetic sensors, emergency stop devices, safety gates Conform to LIFT ...
Comepi srl
... accessories optical, safety relay, 90x118x22mm, 1x NC, 3x NO, Dual channel, Screw connection, Plastic, safety 3x no, 1x nc, terminals Electrical features Betriebsspannung ( DC) 24V Number ...
Trigger voltage: 24 V
... . per channel - Safety Output: N.O. Contact x 3 AC250V 6A (AC Resistive) / AC250V 5A (AC General) / DC24V 5A ( DC General) - Auxiliary Output: N.C. Contact x 1 AC250V 5A (AC Resistive) / AC250V ...
... Safety relay SRA… series, single function, 2NO+1PNP, for two-hand devices, auxiliary supply 24VDC, up to CAT.4, Ple •Type of product: Safety relays •Type of product: Single function •Functions: ...
... accordance with ISO13849-1(Category4, PLe); 2. Relay output: 2 normally open contacts; 3. Transistor output: 4 PNP signal output; 4. Self-diagnose and redundant circuit design; 5. Support a variety of safety ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.