- Robotics - Automation - Industrial IT >
- Automation >
- AC safety relay
AC safety relays
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Tripping current: 4 A
Trigger voltage: 230, 240 V
... supply voltage U1 - AC Inputs Number of inputs - 1 Semiconductor outputs Number of semicond. outputs - 0 Relay outputs Utilisation cat. AC/DC1 stand. - EN 60947-4-1 Utilisation cat. AC15/DC13sta. ...
PILZ
Tripping current: 8, 5 A
Trigger voltage: 230, 240 V
... EN 60947-1 - DC-12 Relay outputs Utilisation cat. AC/DC1 stand. - EN 60947-4-1 Utilisation cat. AC15/DC13sta. - EN 60947-5-1 Safety contacts: AC at UL - 240 ...
PILZ
... Our PNOZ X safety relays are proven through their reliability and sturdiness. They are used in a wide range of applications and in the most diverse safety applications. Use one PNOZ X per safety ...
PILZ
... The first emergency stop module, by DOLD developed in 1988, was called BN 5983 for man-machine protection. Conventional contactor controls have high cost interconnection wiring, but instead of that you can use this product and save a lot of money as ...
... The unit, which is manufactured by Dold, is a safety relay for two-hand controls and is suitable to use in guarding operators from harm caused by hazardous closing movements in work areas such as machinery and plants. ...
Tripping current: 20 mA
Trigger voltage: 24 V
... ISO 13851. In this way, a high level of protection against tampering is provided. • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting ...
Tripping current: 20 mA
Trigger voltage: 24 V
... start with automatic start or a start button • Monitoring of downstream relays or contactors. • Simultaneity monitoring to monitor safety components over time • Relay start using a monitored start ...
Trigger voltage: 24 V
... Centralized fault display. • Power supply 24V ac / dc • 7 entries pnp • 7 two-color LEDs: red = off green = on • 1 NO + NC contact for alarm: • All active inputs engage the contacts. ...
Trigger voltage: 24 V
... Process Safety Sensors 3 NO instantaneous for control heater 2 NO + 1 NC delayed for interlocking Adjustable time with thumbwheels 1 to 999s Power supply: 24Vac / dc Monitoring on 4 leds 45 mm format Security ...
Trigger voltage: 24 V
... EXELTRONIC XXLP : Stop command with 2 NC contacts Self-check entries Compatible with ACOTOM® Process Safety Sensors Adjustable time with thumbwheels 1 to 999s Power supply: 24Vac / dc Monitoring on 4 leds ...
Tripping current: 4, 6 A
Trigger voltage: 24, 250 V
... two-hand switch input. Provide 3 NO instantaneous safety output contacts and 1 NC instantaneous auxiliary output contacts, and provide 2 groups of signal output functional safety relays. Manual ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 24, 240, 250 V
... Supports emergency stop switch, safety door lock, and passive switch inputs Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 24, 240, 250 V
... Supports emergency stop switches, interlock switches, and passive switch inputs Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel ...
Bytorent Technology Co., Ltd.
Trigger voltage: 24 V
... disconnect, switch, or convert voltage - even where space is at a premium. Our product portfolio comprises a diversity of relay and optocoupler modules that use the practical terminal block format. Our analog transformers and temperature ...
Tripping current: 4, 2 A
... operation with the Mechan range of non-contact safety switches, the SRL-1 is also suitable for use with dual channel Emergency Stop buttons, or safety devices with 2 safety outputs e.g mechanical safety ...
Trigger voltage: 24 V
... Current: 166mA max. per channel - Safety Output: N.O. Contact x 3 AC250V 6A ( AC Resistive) / AC250V 5A ( AC General) / DC24V 5A (DC General) - Auxiliary Output: ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group