- Detection - Measurement >
- Optical and Acoustic Measurements >
- Dust sensor
Dust sensors
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Detection range: 0.3 µm - 10 µm
PM2008 laser particle sensor module is based on laser scattering technology, designed with all metal shielding, ultra-thin (12mm) which is used to detect particle concentration size between 0.3μ-10μm exactly in the air ...
Cubic Sensor and Instrument Co.,Ltd
Detection range: 0.3 µm - 10 µm
... Reference instrument: GRIMM Dust Source: Cigarette +Arizona A1 Measurement accuracy for PM10 0 ~100μg/m³, ±30μg/m³ 101 ~500μg/m³, ±30% of reading Condition: 25±2℃,50±10%RH Reference instrument: GRIMM ...
Cubic Sensor and Instrument Co.,Ltd
Detection range: 0.3 µm - 10 µm
PM2009L with anti-dust structure laser particle sensor module is based on laser scattering technology.Detecting particle concentration size between 0.3μ-10μm in the air and real-time output PM1.0、PM2.5、PM10 ...
Cubic Sensor and Instrument Co.,Ltd
... Continuous, precise and reliable dust quantity measurement (mg/m3) • - Dust measurement possible in large channel diameters • - Output of dust concentration as absolute value • - ATEX-certified • ...
ZH10 Compact Laser Dust Sensor Module is a common type, miniature size sensor module, using laser scattering principle to detect the dust particles in air, with good ...
Zhengzhou Winsen Electronics Technology Co., Ltd
Laser Dust sensor module ZH07 is a common type, small size sensor, using laser scattering principle to detect the dust particles in air, with good consistency and stability. ...
Zhengzhou Winsen Electronics Technology Co., Ltd
Laser Dust sensor module is a common type, small size sensor, using laser scattering principle to detect the dust particles in air, with good consistency and stability. ...
Zhengzhou Winsen Electronics Technology Co., Ltd
Detection range: 0.5 µm
PMSX003 is a digital universal particle sensor based on the principle of laser scattering, which can continuously collect and Calculate the number of suspended particles of different sizes in the air per unit volume, ...
SHENZHEN CHENGDI TECHNOLOGY CO., LTD
Detection range: 0.5 µm
... and universal particle concentration sensor,which can be used to obtain the number of suspended particles in the air,i.e.the concentration of particles,and output them in the form of digital interface. This sensor ...
SHENZHEN CHENGDI TECHNOLOGY CO., LTD
Detection range: 0.5 µm
... and universal particle concentration sensor,which can be used to obtain the number of suspended particles in the air,i.e.the concentration of particles,and output them in the form of digital interface. This sensor ...
SHENZHEN CHENGDI TECHNOLOGY CO., LTD
The MIC-600 series fixed six-in-one gas detector is used for 24-hour continuous online monitoring and temperature and humidity measurement of various gas concentrations in the field, displaying the concentration and outputting standard ...
The Dust Alarm® ES dust monitor provides reliable and economical detection of leaks and filter failures in many powder and bulk solids industries. The Dust Alarm® ES detector is designed ...
Detection range: 0.5 µm
Specifications Working Voltage: DC 5V +/-10% (CON2 Pin1=GND, Pin3 = +5V) Voltage ripple below 55mV Working Current: 90mA Operating Temperature and Humidity: 0 ~ 50℃; below 95% rh (no condensation) Storage Temperature: -20 ~ 60℃ Size: ...
Detection range: 0.1 µm - 100 µm
... required Adaptable; suitable for virtually all dust collectors Wide range of duct sizes from 250mm to 2m Typical Dust Monitoring Applications Industrial Manufacturing Power Plants Cement ...
The DC0001-000 is a dust sensor comprised of an optical sensing system that uses counting method to measure dust concentration. When the airflow carrying dust particles ...
... generally fitted in chimneys downstream from the dust filters. The preventive control of the quality of the filtration system allows : - The possible derating of the fan located downstream of the dust ...
... operating costs and improving well-being. We recommend one sensor for every 30 m² of space. An optical particulate sensor precisely detects fine dust (PM) of size categories 0.3 to 10 ...
Room sensor for detection of PM2.5 and PM10 Technical Specifications Operating voltage AC/DC 24 V, DC 24 V Connection cable Micro USB Analog outputs DC 0...10 V Display 3-color LED service indication Communication Modbus ...
... Surface Dust Accumulation monitor detects the levels of accumulated dust in an area. The system continuously monitors the levels of accumulated dust so you can automate workflows and ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining