- Electricity - Electronics >
- Energy: Production and Distribution >
- Encapsulated transformer
Encapsulated transformers
Primary current: 100 A - 5,000 A
... Small size and easy mounting. Range output burden: 100A - 5000A. High accuracy and reliability. TECHNICAL SPECIFICATION - Indoor use. - Policarbonate with self-extinguishing V0. - Sealable secondary terminals. - Highest voltage for equipment, ...
Contrel elettronica
Primary current: 1 A - 4,000 A
... accessories supplied with the CT, Measuring Transformers: the short circuit on terminals or the connection to earth can be achieved by the double fast-on or connecting two wires on the same terminal. And Protection Transformers: ...
Contrel elettronica
Primary current: 500 A - 6,000 A
... The TCB-A is a series of current transformers that are specially made for applications that involve power centers and distribution boards for plant expansion or maintenance. The primary bar does not need to be disconnected because ...
Contrel elettronica
... TAB2 - closed current transformers /5A TAB2: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting the bars both ...
... TAB3 - closed current transformers /5A TAB3: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting the bars both ...
Output power kVA: 4 kVA
Primary voltage: 440 V
Secondary voltage: 380 V
... Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 7.5 kVA
Primary voltage: 220 V
Secondary voltage: 220 V
... Power Isolation transformer: SGGF isolation transformer is used to solve the power grid problems which are caused by the photovoltaic power generation,such as harmonic, flickering, DC magnetic bias, and over voltage. ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 100 kVA
Primary voltage: 380 V
Secondary voltage: 385, 222 V
... Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 Transformers ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes transformers ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
... Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection interface • ...
Tesar Srl
Electric power: 0.03 kVA - 0.25 kVA
Primary current: 0.08 A - 1.35 A
... Transformers have to be flexible because different situations require different voltages. Murrelektronik's product range offers this flexibility, no matter if it's an isolation transformer, control transformer, ...
MURRELEKTRONIK
... chargers Operation: PLC signal transmission OBC with communication with the charging station FEATURES > Signal transformer for HPGP (HomePlug Green PHY™) PLC modems > For power line communication devices acc. to IEC 15118 standard ...
PREMO
Primary current: 200 A
... Function: Transformers are components for detecting residual currents in connection with evaluation units such as DRCM, DMRCD or MFR. Transformers in combination with evaluation units are suitable for measuring and/or ...
Doepke Schaltgeräte GmbH
Secondary voltage: 5 V - 120 V
... 20 output voltages to choose from (5 - 120VAC R.M.S.) Six VA size models available from - .5 to 24 VA Vertical mount, split bobbin design. 1.2, 4.4, 10, 24 VA models are non-concentric wound. 0.5 and 1 VA are both concentric wound. Low primary to ...
Hammond
... frequency (HF) transformers, in particular ferrite transformers and ferrite coils as an associated important component. Thanks to its many years of experience, KUK can meet the most diverse requirements in the manufacture ...
KUK Coils
Primary current: 1 A - 300 A
Secondary current: 5, 1 A
Frequency: 40 Hz - 60 Hz
... Winding primary current transformer Protection current transformer Fixing with DIN rail and wall mounting 6mmq terminals connection Small size High performance Maximum precision ...
AB TRASMISSIONI SRL
Primary current: 1 A - 7,500 A
Frequency: 50, 60 Hz
... EBONY EXCEL RANGE Crompton Instruments Ebony Excel and Ebony Excel Plus range of Current Transformers offer wide system current ratings, apertures, busbar and case sizes to suit every application. Manufactured to meet IEC61869-2, the ...
Crompton Instruments
Electric power: 0.06 kVA - 1 kVA
Primary voltage: 230 V
Secondary voltage: 115 V
... General Data Rated input voltage 230 Vac Rated output voltage 2 x 115 Vac Rated power 60 ‑ 1000 VA Insulation class A or B Maximum ambient temperature 40 °C Efficiency up to 95 % Degree of protection IP 20 Advantages Safe galvanic isolation Integrated ...
Block Transformatoren-Elektronik
Electric power: 0.024 kVA
Primary voltage: 230 V
Secondary voltage: 24 V
... The CA1A is an economical transformer which reliably delivers either 12Vac or 24Vac and benefits from short circuit protection. Ideal for running a simple keypad and electric strike, this transformer is perfect for small-scale ...
Output power kVA: 0.72 kVA
Primary current: 50 A - 300 A
Secondary current: 1 A - 5 A
... Solid core Current transformer 100A/1A Specifications Rated primary current 100 A Output 1 A Hole diameter 24 mm (0.94 in) Accuracy class ...
CARLO GAVAZZI
Output power kVA: 0.01 kVA - 0.25 kVA
Primary voltage: 4 V - 250 V
Secondary voltage: 24 V
... Edwards 88 Series Transformers provide low voltage source from 50 to 250 volt amps for all large signaling installations. Holes provided in transformer housing for surface mounting. The Edwards 88 Series heavy duty ...
Primary current: 5 A - 450 A
... Current transformer with built-in transducers ø 35mm Primary current field-selectable 9 programmable ranges Output 0..,20mA - 4..,20mA - 0...10V d.c. 4-wire technology, a.c. auxiliary supply ...
IME Spa
Electric power: 0.01 kVA - 31.5 kVA
... The TR 21 CONTROL Transformers is a control and safety or seclude single-phase transformers. This device employs the principle of mutual induction to proselytize variations of current in a primary circuit into variations ...
DF ELECTRIC
Output power kVA: 0.04 kVA - 5 kVA
Primary voltage: 230, 400 V
Secondary voltage: 115, 230 V
... Dry type transformer. Encapsulated in IP20 resin. No electrical part of the transformer is directly accessible by the user. Full power in all the shots. Tension selection through metal bridges ...
POLYLUX
Electric power: 30 W
Primary voltage: 230 V
Secondary voltage: 14 V
Double-insulation to handle the cold. IP rating of IP44. 230V/14VDC, 30W. Socket for transfer to a 12/24V plug.
Primary voltage: 110, 240 V
Secondary voltage: 24, 12 V
... holes. These transformers are resin encapsulated and have a 3VA burden rating enabling them to power other low voltage monitors, alarms or control circuits that require a 12Vac or 24Vac supply. Product Features Encapsulated ...
Primary voltage: 12, 11, 10 kV
Secondary voltage: 100 V - 240 V
Frequency: 60, 50 Hz
... Description: This product is fully enclosed outdoor single-phase voltage transformer, epoxy resin and silicone rubber composite insulation pillar structure, the outer sheath and umbrella skirt are made of high temperature vulcanized ...
Electric power: 0.1 W
Primary voltage: 3 V - 12,000 V
Secondary voltage: 3 V - 24 V
... Product Overview: Pulse transformers for communication have excellent high-frequency performance, strong signal isolation, and stable transmission. They are crucial enablers for the stable operation of communication networks. Specific ...
LUSHAN CHINA
Primary voltage: 230, 115 V
Secondary voltage: 4.5 V - 24 V
... Standard Series:designed for lower power and miniature products center tapped::2x(4.5+4.5/6+6/7.5+7.5/9+9/12+12/15+15/18+18/24+24) ...
Electric power: 0.03 kVA - 4 kVA
Primary voltage: 100 V - 690 V
Secondary voltage: 12 V - 250 V
... Designed and tested according to: • IEC/EN 61558-2-2 • VDE 0570-2-2 • UL 506 • CSA 22.2 no. 66 For use according to: • IEC/EN 60204-1 / ÖVE EN13 • VDE 0113 / VDE 0100 part 410 Typical applications: • Control voltage circuits • Functional ...
Trafomodern Transformatorengesellschaft
... fields are very small in comparison with conventional transformers because of the optimum winding construction. This can result in a reduction in size and weight of up to 50%. GETRA toroidal transformers are therefore ...
Getra
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.