Encapsulated transformers

121 companies | 477 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
current transformer
current transformer
CTD1X1001A SERIES

Output power kVA: 0.72 kVA
Primary current: 50 A - 300 A
Secondary current: 1 A - 5 A

... Solid core Current transformer 100A/1A Specifications Rated primary current 100 A Output 1 A Hole diameter 24 mm (0.94 in) Accuracy class ...

See the other products
CARLO GAVAZZI
electrical power supply transformer
electrical power supply transformer
88 series

Output power kVA: 0.01 kVA - 0.25 kVA
Primary voltage: 4 V - 250 V
Secondary voltage: 24 V

... Edwards 88 Series Transformers provide low voltage source from 50 to 250 volt amps for all large signaling installations. Holes provided in transformer housing for surface mounting. The Edwards 88 Series heavy duty ...

instrument transformer
instrument transformer
TT35A series

Primary current: 5 A - 450 A

... Current transformer with built-in transducers ø 35mm Primary current field-selectable 9 programmable ranges Output 0..,20mA - 4..,20mA - 0...10V d.c. 4-wire technology, a.c. auxiliary supply ...

See the other products
IME Spa
power transformer
power transformer
TR 21 series

Electric power: 0.01 kVA - 31.5 kVA

... The TR 21 CONTROL Transformers is a control and safety or seclude single-phase transformers. This device employs the principle of mutual induction to proselytize variations of current in a primary circuit into variations ...

See the other products
DF ELECTRIC
current transformer
current transformer
LZMK-10

Primary voltage: 10 kV
Secondary voltage: 0.2 V - 10 V
Primary current: 5 A - 2,000 A

... Product Details
The LZMK-10 current transformer maintains accuracy stability between -5~40C through thermally optimized casting structure. Unique magnetic shunt design ensures composite error ≤0.1%, ideal for high-precision ...

See the other products
Ximai Electric (Wuhan) Co.,Ltd
power transformer
power transformer
ND series

Output power kVA: 0.04 kVA - 5 kVA
Primary voltage: 230, 400 V
Secondary voltage: 115, 230 V

... Dry type transformer. Encapsulated in IP20 resin. No electrical part of the transformer is directly accessible by the user. Full power in all the shots. Tension selection through metal bridges ...

See the other products
POLYLUX
isolation transformer
isolation transformer
790500

Electric power: 30 W
Primary voltage: 230 V
Secondary voltage: 14 V

Double-insulation to handle the cold. IP rating of IP44. 230V/14VDC, 30W. Socket for transfer to a 12/24V plug.

electrical power supply transformer
electrical power supply transformer
TRA series

Primary voltage: 110, 240 V
Secondary voltage: 24, 12 V

... holes. These transformers are resin encapsulated and have a 3VA burden rating enabling them to power other low voltage monitors, alarms or control circuits that require a 12Vac or 24Vac supply. Product Features Encapsulated ...

power transformer
power transformer
JDZW series

Primary voltage: 12, 11, 10 kV
Secondary voltage: 100 V - 240 V
Frequency: 60, 50 Hz

... Description: This product is fully enclosed outdoor single-phase voltage transformer, epoxy resin and silicone rubber composite insulation pillar structure, the outer sheath and umbrella skirt are made of high temperature vulcanized ...

pulse transformer
pulse transformer
QY21-5

Electric power: 0.1 W
Primary voltage: 3 V - 12,000 V
Secondary voltage: 3 V - 24 V

... Product Overview: Pulse transformers for communication have excellent high-frequency performance, strong signal isolation, and stable transmission. They are crucial enablers for the stable operation of communication networks. Specific ...

See the other products
LUSHAN CHINA
power transformer
power transformer
E Series

Primary voltage: 230, 115 V
Secondary voltage: 4.5 V - 24 V

... Standard Series:designed for lower power and miniature products center tapped::2x(4.5+4.5/6+6/7.5+7.5/9+9/12+12/15+15/18+18/24+24) ...

electrical power supply transformer
electrical power supply transformer
STN

Electric power: 0.03 kVA - 4 kVA
Primary voltage: 100 V - 690 V
Secondary voltage: 12 V - 250 V

... Designed and tested according to: • IEC/EN 61558-2-2 • VDE 0570-2-2 • UL 506 • CSA 22.2 no. 66 For use according to: • IEC/EN 60204-1 / ÖVE EN13 • VDE 0113 / VDE 0100 part 410 Typical applications: • Control voltage circuits • Functional ...

See the other products
Trafomodern Transformatorengesellschaft
power transformer
power transformer
RW

... fields are very small in comparison with conventional transformers because of the optimum winding construction. This can result in a reduction in size and weight of up to 50%. GETRA toroidal transformers are therefore ...

See the other products
Getra
power transformer
power transformer

Primary voltage: 110, 20 kV

Audio-frequency remote control systems are reliable and proven solutions for the remote control of devices in supply networks. We can supply coupling units for the serial and parallel supply of audio-frequency remote control systems in 110 kV and 20 kV ...

current transformer
current transformer
VE-CT21

Primary current: 40 A - 300 A
Secondary current: 1, 5 A

... Primary Current Range 40A to 300A Secondary Current Options 5A or 1A Width 44mm Cable Aperture 21mm Cable 21mm Cable aperture Housing Features a sealable terminal cover Design Compact, making it suitable for spaces with limited ...

See the other products
Voltek Energy Limited
power transformer
power transformer
VB24 - VB36 series

Electric power: 0.005 kVA - 0.1 kVA
Primary voltage: 24 kV - 36 kV
Secondary voltage: 100 V - 120 V

... 12-24-36 kV Single Pole Insulated Block Type Design Standard: IEC 60044-2, VDE 0414, ANSI, GOST ...

See the other products
alce elektrik san ve tic as
instrument transformer
instrument transformer
FAT series

Electric power: 0 kVA
Primary voltage: 0 V
Secondary voltage: 0 V

See the other products
Federal Elektrik
isolation transformer
isolation transformer

Electric power: 0.01 kVA
Secondary voltage: 4, 8, 12 V

... 10VA transformer for continuous service, outputs 4-8-12V 2 DIN Power supply 230V a.c. – 50Hz Outputs 4-8-12V Installation on terminal board IP20 Wall-mounted IP30 Installation on the rear of the switchboard IP40 Dimensions (LxWxH) 35 ...

current transformer
current transformer
CMD® II

Electric power: 40 W
Primary voltage: 12 V - 250 V
Primary current: 1 A

... Non-Contact Current Transformer Enhance your Smart Grid A non-contact current transformer measures three-phase current at line voltages to protect power systems and to provide critical real-time information to protection ...

power transformer
power transformer

Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
Frequency: 60, 50 Hz

... SummarThe 35kV transformer, the use of company-specific calculation and verification procedures, the transformer core, coils, active part, leading tanks and other components for a full range of optimized design and verification, ...

current transformer
current transformer
LZCK-55

Secondary voltage: 1, 5 V
Primary current: 1, 5 A

... outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer ...

current transformer
current transformer
SCT027H

Primary current: 160 A

... Characteristics:Hand hold type, leading wire output, audio plug connector(or customized), transient voltage suppressor built in. Application: used for the current measuring, monitoring and protecting of AC motor, lighting equipment and air compressor. ...

See the other products
YHDC Dechang Electric
instrument transformer
instrument transformer
TAB series

... This linear current transformer series, allow to obtain an AC or DC voltage on output without other transducer. This solution reduce the cost and space of the installation. Mechanical dimension and primary current on main characteristics ...

See the other products
F.C. Misure
electrical power supply transformer
electrical power supply transformer
ZTR-15-12

Primary voltage: 230 V
Secondary voltage: 4 V - 12 V

... Bell transformer ZTR-15-12Designated for general use – e.g. as home bells supply, door locks supplyDESCRIPTION Short-circuit-proof, doubled output terminalsTECHNICAL PARAMETERS Input voltage: AC 230 V Output voltage 4 V, 8 V, ...

See the other products
ELKO
current transformer
current transformer
CT1231-A1

Primary current: 30 A

... Current transformers for energy meters single phase and three phase metering in Residential Metering applications. KEY FEATURES •High Linearity •Low cost •PCB Mountable •High Over current withstand capability RELATED APPLICATION •Metering ...

See the other products
Electrohms
electrical power supply transformer
electrical power supply transformer
STR-ST

Primary voltage: 230 V

... Execution in accordance to VDE 0570 / EN 61558 Prepared for units to protective class II Protective type IP 00 Thermal class E Nominal ambient temperature ta 40°C Input voltage: 230V Output voltage: up to 42V Frequency: 50/60Hz Impregnation Test ...

instrument transformer
instrument transformer

... to give a signal, if the AC current exceeds a preselected setpoint. The setpoint is adjusted on a potentiometer on the transformer. 2. Current converters. These units converts the primary AC current to a standard 4-20 mA DC output ...

control transformer
control transformer
C series

Output power kVA: 0.025 kVA - 5 kVA
Primary voltage: 100 V - 600 V
Secondary voltage: 12 V - 600 V

... additional accredited bodies. Our transformers offer good access to the four-hole fixing, touch-proof terminals and full varnish impregnation to protect against humidity. • Control Transformer : Class 1 Isolation ...

See the other products
Boardman Transformers
power transformer
power transformer

Output power kVA: 3,000 kVA - 15,000 kVA

... engineers’ design and monitors the production of these transformers. The engineers involved in the manufacturing process of transformers are highly skilled, expert and efficient. All our transformers ...

summation transformer
summation transformer
SSR-21 series

Output power kVA: 0.015 kVA
Secondary voltage: 720 V
Secondary current: 5, 1 A

... Electrical properties Test insulation voltage 4 kV, 1 min. Rated short-time thermal current (Ith) 60 x IN Dynamic rated current (dyn) 2.5 x Ith Self-consumption Max. 4 VA Installation class E Mechanical properties Housing Made of self-extinguishing ...

See the other products
Celsa Messgeräte GmbH
current transformer
current transformer

Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V

... The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase difference. The network's HV side delivers isolation ...

See the other products
ENTES
instrument transformer
instrument transformer

... SES Current Transformers (CT) are used to ensure that electrical systems do not overload and for monitoring large loads by the using a metering instrument. Selection of accurate and reliable CTs are very crucial. It has a tool to measure ...

See the other products
Success Electronics & Transformer Manufacturer Sdn
power transformer
power transformer
EI, EE, ER, ERT, ETD, EFD, EP, PQ, RM

Transformers of models EI and EE are applied in a wide range and offer ahigh working frequency and wide range of working voltages plus strong output power and good ability in thermal stability。They have been widely used in program controlled ...

current transformer
current transformer
C-08

Primary current: 15, 20, 5, 10 A
Secondary current: 2 mA - 20 mA
Frequency: 50, 60 Hz

... CURRENT TRANSFORMERS FOR ELECTRONIC ENERGY METERS FEATURES: -Adopted high permeability core, high accuracy, excellent linear performance; -Anti-combustion plastics case; - Encapsulated with epoxy resin with strong ...

See the other products
Yueqing RunEasy Electronic Technology Co.,Ltd.
current transformer
current transformer
CTS-120

Electric power: 0.144, 0.096, 0.06, 0.12 kVA
Secondary voltage: 1.2, 0.8, 0.5 V
Primary current: 120, 0.6 A

... high allowable load impedance and high accuracy enable the CTS transformer to be rigidly integrated with a meter testing system. Once integrated, it can handle both self-contained and transformer connected meters, also ...

current transformer
current transformer
ASK & ASR

Primary voltage: 1,200, 720 V
Primary current: 40 A - 7,500 A
Secondary current: 1, 5 A

... current transformer range, these measuring transformers convert high current into lower nominal current value, thus making it possible to use instruments and relays with standardised values of rated current. Part of ...

See the other products
DEIF
current transformer
current transformer
CTS-SC Series

Primary current: 60 A - 630 A
Secondary current: 5, 1 A
Frequency: 50 Hz - 60 Hz

... 3-in-1 Solid Type CE/ROHS Approved Electrical Specifications • Insulation Voltage : 720V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Dielectric Strength : 3.0kV/1mA/1min Mechanical Specifications • Operating Temperature ...

isolation transformer
isolation transformer
LH series

Electric power: 0.04 W - 5 W
Primary voltage: 230, 400 V
Secondary voltage: 24 V - 230 V

... isolating / isolation transformers, which are protected against direct contact. Products in the LH-series are designed with maximum versatility in every transformer’s functions and technical features. Therefore, the ...

See the other products
Muuntosähkö Oy - Trafox
isolation transformer
isolation transformer
STM series

Output power kVA: 0.03 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24 V - 230 V

... SINGLE PHASE ISOLATING TRANSFORMERS IP00 Modern and economical make of general purpose isolating and/or safety transformers for building into installations and industrial or power engineering devices. This isolating, ...

See the other products
BREVE-Tufvassons
isolation transformer
isolation transformer

Electric power: 7.5 kVA - 440 kVA
Primary voltage: 460 V - 575 V
Secondary voltage: 133 V - 460 V

... SCR (Silicon Control Rectifier) variable speed motor drive applications, a transformer is needed to magnetically isolate the incoming line from the motor drive. The transformer must also provide a voltage change to match ...

See the other products
SolaHD
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
DirectIndustry RFQ: Free quotation comparison tool
Receive and compare quotations for free
Describe your project
We select
the best suppliers
Compare quotations and complete your purchase