- Electricity - Electronics >
- Energy: Production and Distribution >
- Cast resin transformer
Cast resin transformers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

GE’s cast coil transformer is a low-noise, low-loss, cast resin dry-type transformer. The high-voltage winding with copper conductors and the low-voltage ...

Core balance transformers protects or signals resources such as earth leakage protection relays. this transformer or toroid proposed by SOCOMEC meet requirements in terms of measurement sensitivity and ...
SOCOMEC

Primary current: 100, 1,000 A
Secondary current: 5 A
Frequency: 40 Hz - 65 Hz
... protected. The current transformers used (to be ordered separately) must be of the same type; for upgrading of existing systems are particulary well suited the split core transformers ( see codes TAA030..., ...
FRER

Primary current: 200, 2,000 A
Secondary current: 5 A
Frequency: 40 Hz - 65 Hz
Adapter transformer for differential currents 200-2000/5A
FRER

Primary current: 300, 3,000 A
Secondary current: 5 A
Frequency: 40 Hz - 65 Hz
Adapter transformer for differential currents 300-3000/5A
FRER

Primary current: 125 A
Efficient current transformers that have been specially designed to be installed on top of a switch. The most important feature of these split-core transformers is that they are very easy to install. ...
CIRCUTOR

... Series, manufactured by Circutor, is a current instrument transformer that is used to determine the measurement of rotating electric currents. This transformer is especially compressed in resin ...
CIRCUTOR

Primary current: 100 A - 3,000 A
Frequency: 50, 60 Hz
Current transformers used in Low Voltage installations, in applications with official measurements and used to bill energy, since they comply with the specifications of the Spanish electricity companies. Resin ...
CIRCUTOR

Output power kVA: 0 kVA - 0.01 kVA
Primary current: 40 A - 1,250 A
Frequency: 40 Hz - 60 Hz
"MINIATURE" measuring current transformers for currents

... standard and application-specific transformers that maximize the high-performance characteristics of their materials. The extensive product lineup includes low-loss power transformers for power supplies, ...
TDK Electronics Europe

Pasternacks matching pads are passive coaxial components that allow impedance matching between 50 Ohm and 75 Ohm systems without introducing a lot of reflection to the circuit. For applications requiring a connection between a 50 Ohm ...

The production of cast resin power transformers can be divided in: Standard Production, which includes distribution transformers with rated power up to 3.150 kVA ...

The production range of metering transformers includes: Current transformers, rated nominal current up to 3.000 A. Ring type transformers, primary current up to 20.000 A. ...

The production range of metering transformers includes: Current transformers, rated nominal current up to 3.000 A. Ring type transformers, primary current up to 20.000 A. ...

Output power kVA: 7.4 kW - 626.7 kW
... a series of transformer products, including 6300~80,000kVA double-winding and three-winding non-excitation voltage-regulating power transformer, 6300~80,000kVA double-winding and three-winding on-load ...

Output power kVA: 0.04 kVA - 2.5 kVA
Primary voltage: 230, 400, 460 V
Secondary voltage: 115, 230 V
Dry type cast resin transformer Advantages of resin technology: • Protection against corrosive environments • Protection against high vibration levels • Protection ...

Output power kVA: 0.63 kVA - 400 kVA
Primary voltage: 400 V
Secondary voltage: 400 V
TT transformers are used for insulation galvanic three-phase installations for reasons of security. They are also used in the generation of neutrals referenced to ground in single-phase installations of high power. Dry ...

TAB1- closed current transformers /5A TAB1: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting ...

Primary current: 0 A - 2 A
Secondary current: 0 mA - 2 mA
Frequency: 50 Hz
Mini Voltage Transformer Occasion of use: Generally used in instruments and meters with high space requirements for testing voltage, electric energy and power; Principle of use: Primary and secondary 2 mA: 2 mA current, ...

Primary current: 5 A - 200 A
Secondary current: 2 mA - 200 mA
Frequency: 50, 60 Hz
Mini PCB Current Transformer Generally used in measuring instruments, as the secondary transformer of the instrument, convert 1 A, 5 A into mA current, For instrument use; Specifications Current ...

Primary voltage: 0.7 kV
Primary current: 60 A - 5,000 A
Secondary current: 5, 1 A
Resin cast CTs of LRC series are molded with epoxy resin. This is a recommended solution for outdoor applications exposed to adverse environmental factors ...

Electric power: 10 kVA
Primary voltage: 220, 380 V
Secondary voltage: 380, 220 V
... Copper Insulation :F/H Standard: EN61558-2-6 Range :30kva to as you requested Application : electrical control transformer
Shenzhen Sikes Electric Co., Ltd.

Output power kVA: 60 kVA
Primary voltage: 220, 380 V
Secondary voltage: 220, 380, 600, 800, 1,000 V
Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer can isolate the former ...
Shenzhen Sikes Electric Co., Ltd.

Electric power: 50 kVA - 1,000 kVA
Primary voltage: 300 V
Secondary voltage: 400 V
Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer can isolate the former ...
Shenzhen Sikes Electric Co., Ltd.

Primary current: 25 mA - 1,000 mA
Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Ignition current up to 3 A Turns ratio up to 3:1 Ignition currents : 0.1 to 3 A Rise time : 0.3 to 2.3 µs Frequency : ≤ 40000 Hz Attenuation performance ...
SCHAFFNER Group

Primary voltage: 230 V - 400 V
Secondary voltage: 24 V - 230 V
General Data Rated input voltage 230 ‑ 400 Vac Rated output voltage 24 ‑ 230 Vac Rated power 63 ‑ 2500 VA Insulation class B Maximum ambient temperature 40 °C Efficiency up to 95 % Degree of protection IP 00 Advantages Very good switch‑on ...
Block Transformatoren-Elektronik

Electric power: 100 kVA - 10,000 kVA
Primary voltage: 3.3 kV - 36 kV
... systems, and industrial and off-shore installations. The CG Power Systems cast resin transformers proved that these product is accuracy and have high quality performance. In India, its ...
CG Power Systems

Electric power: 500 kVA - 12,500 kVA
Primary voltage: 6.6 kV - 33 kV
... -end power and industrial equipment and solutions. It offers converter transformers that operate at the fundamental frequency of an alternating system. These converter transformers are intended for one ...
CG Power Systems

Electric power: 3,900 kVA - 10,000 kVA
Primary voltage: 25 kV
... 3900 kVA Foil Wound, 5400 kVA Foil Wound, 6500 kVA and 7500 kVA for 3-phase Loco are transformers intended for seismic and short-circuit conditions. The transformers are supplied with an H-class conductor ...
CG Power Systems

Three-phase reactors intended for the attenuation of notches and spikes, reduction of harmonics and limitation of inrush currents in converters and variable speed drives. Drop voltage of 4% of the rated voltage (400V). Manufactured with ...

Primary voltage: 50 V - 300 V
Secondary voltage: 5 V
Ebony Series Measuring and Protection The range of Crompton Instruments Ebony current transformers offers wide system current ratings, apertures, busbar and case sizes to suit every application. Manufactured to meet ...

Output power kVA: 20, 18, 25, 24 kVA
Ignition transformers for electronic ignition circuits For one or two ignition points Primary: Solder pins for PCB mounting Secondary: fastons 2.8 x 0.8 mm Small dimensions Circuit board ...

Output power kVA: 0 kVA - 3,150 kVA
Primary voltage: 10 kV - 33 kV
Secondary voltage: 400 V
... T.HE resin transformers are manufactured according to EN 50708-2-1 and comply with the provisions of Regulation 2019/1783 of the European Commission, which describes the mandatory requirements for the ...

We produce systems for measurement transformers with various types of resin (epoxy, polyurethane, etc.) Fully automated production lines Positioning on the X-Y axes for automated resin ...

Electric power: 0.05, 0.1, 0.2 kVA
Primary voltage: 230, 120 V
Secondary voltage: 110, 230 V
Isolating transformers, according to the VDE and EN instructions. Type TTGN 2 is a plug-in unit which is plugged directly into the 230 V main socket. Types TTGN 20 mounted in a steel-case with a handgrip. Types ...
HSGM

Elektrotechnik's controllable transformer is a ready-to-connect power supply solution. This transformer aids in providing a power supply either as a 24V control voltage or 8000 V anode voltage. The manufacturer ...
J. Schneider Elektrotechnik

Electric power: 0.0004, 0.0005 kVA
Primary voltage: 230 V
Secondary voltage: 6 V - 24 V
... and long-term durability individually tested with certificate excellent reaction to temperature changes self-extinguishing cast housing and sealing material
HAHN - Elektrobau
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining