- Industrial machines and equipment >
- Heat Exchanger and Refrigeration >
- Explosion-proof cooler
Explosion-proof coolers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Power: 40 W
Maximum temperature: 50 °C
Pressure: 10 bar
... Suitable for use in measuring equipment conforming with 17th BImSchV (German Federal Immission Protection Law) Explosion- proof versions with ATEX and CSA certifications Compact surface mounting case ...
Power: 5,000 BTU/h
Maximum temperature: 80 °F - 100 °F
Flow rate: 70 ft³/min
... Vortex A/C Coolers incorporate the most up-to-date features into Vortec’s line of highly reliable, cost effective enclosure coolers. - Sleek, modern design - Noise reduction of 78%, when compared to other vortex ...
ITW Air Management
Power: 5,000 BTU/h
Maximum temperature: 24 °C - 38 °C
Flow rate: 70 ft³/min
... Vortex A/C Coolers incorporate the most up-to-date features into Vortec’s line of highly reliable, cost effective enclosure coolers. - Sleek, modern design - Noise reduction of 78%, when compared to other vortex ...
ITW Air Management
Power: 900 BTU/h
Maximum temperature: 75 °F - 100 °F
Flow rate: 15 ft³/min
... Vortex A/C Coolers incorporate the most up-to-date features into Vortec’s line of highly reliable, cost effective enclosure coolers. - Sleek, modern design - Noise reduction of 78%, when compared to other vortex ...
ITW Air Management
Maximum temperature: -150 °C - 30 °C
... pipeline to prevent contamination and water vapor at low temperature; maintains purity of cooling medium
Maximum temperature: -10 °C - 50 °C
... - Compressor gas cooler for 1 Jet-Stream heat exchanger with a gas flow rate of max. 250 Nl/h - Explosion- proof version according to ATEX for zone 2 - Adjustable gas outlet dew point ...
Maximum temperature: 5 °C - 45 °C
... - Compressor gas cooler with 1 Jet-Stream heat exchanger made of Duran® glass - With a gas flow rate of max. 1 x 250 Nl/h - Explosion- proof version according to ATEX for zone 1 - Housing ...
Power: 10 kW - 6,000 kW
Maximum temperature: 2 °C - 90 °C
... such as anti-corrosion, sea water chiller with different material design. Power supply range has 6kv, 6.6kv, 10kv Product Detail High Voltage Centrifugal Water-Cooled Chiller Centrifugal Water-Cooled Chiller ...
H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.
Power: 1.5 kW
Maximum temperature: 35 °F - 65 °F
Flow rate: 2, 2.4, 3.6, 4.8 us gal/min
... PCA Series Packaged Chiller by AEC are specially engineered for small, demanding industrial applications. Each self-contained unit is designed for immediate hook-up and is ready to supply clean, cooling water at constant temperatures. Control ...
AEC, Inc. - ACS Group
Maximum temperature: 60 °C
... Cost-effective cooling for sampling close to the process thanks to our passive cooling system - low-maintenance and explosion- proof. Samples of fluids and gases in industrial plants are often very ...
Power: 290 W - 4,500 W
Maximum temperature: -40 °C - 55 °C
Flow rate: 85 m³/h - 4,443 m³/h
... Outdoor enclosure cooling Protection ratings reach up to IP64 or UL type 12, 3, 3R, 4. These features make them ideal for installation in outdoor cabinets, ensuring top performance with minimal maintenance. Both internal and external mounted versions ...
Power: 17, 3 kW
Maximum temperature: 70 °C
Flow rate: 30 l/min
... ATEX approved oil supply system is designed for stationary operation for the cooling and filtering of gear oils Universal Hydraulik GmbH now also develops and builds oil supply systems which can be used in potentially explosive environments. ...
Power: 5 kW
Maximum temperature: 0 °C - 60 °C
... Atex explosion- proof fluid cooler for cooling emergency decontamination showers situated in the refining plants ...
Maximum temperature: 5 °C - 50 °C
... Compressor Cooler Nominal capacity 615 kJ/h respectively 583 Btu/hr 1 or 2 gas paths Stainless steel, glass or PVDF heat exchanger Status display Up to 45 °C / 113 °F ambient temperature Approvals: ATEX, EAC Ex, IECEx This ...
Power: 125 W
Maximum temperature: -40 °C - 70 °C
... designed to protect electronics equipment enclosures from overheating. Utilizing reliable Peltier cooling technology, FHP-750 coolers protect electronic controls, electrical equipment, cabinets, railway signal controls, automation controls, ...
TECA (ThermoElectric Cooling America)
liquid chillerChiller Refrigeration System SUNDI
Power: 2 kW
Maximum temperature: -45 °C - 180 °C
Flow rate: 10 l/min
... 冷却加熱温度制御の利点と機能: 120℃〜350℃の温度範囲、優れた性能、独自の、高精度、インテリジェントな温度制御。 0.5〜1200kWの高い冷却能力、最高の生産安定性、再現性のある結果。 多機能アラームシステムと安全機能、プレート式熱交換器、チューブ型ヒーターを使用して、加熱と冷却の速度を上げます。 7インチおよび10インチカラーTFTタッチスクリーングラフィックディスプレイ、磁気駆動ポンプを使用、再シール漏れの問題はありません。 完全な気密システム、熱伝導率の液体寿命の延長、非常に広い温度範囲、液体媒体を交換する必要はありません。 超高温冷却技術は、300度の高温から直接冷却できます。 原理と機能には、スタッフを使用する多くの利点があります:体の熱伝導媒体の空洞の膨張のみが空気中の酸素と接触するため(および膨張タンクの温度は室温から60度まで)、酸化と空気中の水分のリスク。 熱伝導媒体は高温で蒸発せず、-80℃〜190℃、-70℃〜220℃、-88℃〜170℃、-55℃〜250℃、-30℃〜300℃の連続温度に達することができます。加圧なしの制御。 冷凍加熱温度制御システムの典型的な応用: 高圧反応容器の冷熱源の動的温度制御、二重層ガラス反応ケトルの動的温度制御、二重層反応炉の冷温源の動的温度制御。 マイクロチャネルリアクタサーモスタット制御、小型温度制御システム、蒸気供給システム温度制御、材料低温エージング試験。 化学薬品による低温源熱源、半導体装置の冷却加熱および真空チャンバの加熱温度の温度制御が制御される。 冷凍の温度制御システムの利点と機能: 温度範囲は120〜350で、優れたユニークで高精度のインテリジェントな温度制御が可能です。 0.5〜1200kWの高い冷却能力、最高の生産安定性と繰り返し可能な結果 多機能警報システムと安全機能、プレート熱交換器、チューブ型ヒーターを使用して加熱と冷却の速度を上げます。 7インチと10インチカラーTFTタッチスクリーングラフィックスディスプレイ、磁気駆動ポンプを使用し、再シール漏れの問題はありません。 フル気密システム、熱伝導率の高い液体寿命、非常に広い温度範囲、液体媒体を交換する必要はありません。 超高温冷却技術は、高温の300度から直接冷却することができます。 原理と機能はスタッフを使用することに多くの利点があります:体内の熱伝導媒体の空洞の膨張が空気中の酸素(および室温〜60度の膨張タンク温度)に接触するだけで吸収される熱伝導媒体が低くなります酸化および空気湿気の危険性がある。 高温で熱伝導媒体が蒸発せず、加圧なしで-80~190度、-70~220度、-88~170度、-55~250度、-30~300度の連続温度制御が可能です。 ...
Wuxi Guanya Temperature Refrigeration Technology Co. Ltd..
Power: 20 kW - 150 kW
... Efficient room cooling with a low cost of ownership. Leading edge precision cooling solutions specifically designed to maintain temperature and humidity within extremely tight tolerances. Perfect for racked and non-racked IT loads, these units meet ...
... Custom designed solutions with guaranteed operational performance These are complete pure-water cooling systems for various industrial applications with cooling capacity from 2 kW up to several megawatts. These solutions are for a wide ...
Power: 1.8 kW - 6.5 kW
Maximum temperature: -20 °C - 55 °C
Flow rate: 400 l/h - 1,500 l/h
... of cooling water are needed, BARTEC BENKE closed loop chillers can be supplied to meet these applications. The chillers can be supplied with diverse refrigerating capacities which allow the chillers to ...
Maximum temperature: 1 °C - 37 °C
... The air-cooled OMAX Chiller optimally supplies inlet water at a consistent temperature, which extends pump seal life for longer, more sustainable production. Using the 5 Ton Chiller or larger also allows for seamless ...
Maximum temperature: -40 °C - 120 °C
... High and low temperature test chiller Application Flow resistance test Heat dissipation efficiency test Voltage drop test Thermal fatigue test Withstand voltage test Pulse test High and low temperature simulation test High ...