- Electricity - Electronics >
- Energy: Production and Distribution >
- High-current transformer
High-current transformers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary voltage: 22 kV - 36 kV
Secondary voltage: 600 V - 800 V
... designed to ensure high-performance in demanding and severe operating conditions. What are transformers for special applications? Some industrial applications require specific transformers due to ...
Primary current: 5 A - 20 A
Secondary current: 50 mA - 660 mA
Frequency: 50 kHz - 500 kHz
... Pico current sense transformers are designed for load management for power circuit protection. They provide the safest step-up current monitoring by allowing measurement of the current ...
Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
Secondary voltage: 13.2 kV
... Solar & Energy Storage MV
Transformer Station
• IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature ...
Dowei Electric
Output power kVA: 630 kVA - 63,000 kVA
Primary voltage: 66,000 V
Secondary voltage: 13,200 V
... temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m ...
Dowei Electric
Output power kVA: 6,300 kVA - 120,000 kVA
Primary voltage: 110 kV
Secondary voltage: 13.2 kV
... temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m ...
Dowei Electric
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 Transformers ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes transformers ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
... Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 ( high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection ...
Tesar Srl
Primary current: 1 A - 300 A
Secondary current: 5, 1 A
Frequency: 40 Hz - 60 Hz
... Winding primary current transformer Protection current transformer Fixing with DIN rail and wall mounting 6mmq terminals connection Small size High performance Maximum ...
Primary voltage: 0 V - 170,000 V
Secondary voltage: 0 V - 750,000 V
Primary current: 0 A - 100,000 A
... industrial applications to electrolysis processes with high secondary currents (up to 100 kA) and high harmonic content Rectifier transformers are manufactured according to the experience ...
SEA
Output power kVA: 135 kVA
Primary voltage: 380 V
Secondary voltage: 23 V
... -phase dry-type transformer is specially designed for vacuum furnaces to achieve voltage reduction and current increase. Specific Introduction: 1. High Impedance Ensures Safety and High ...
LUSHAN CHINA
Primary voltage: 480, 600 V
Secondary voltage: 280, 120, 240 V
... electrical isolation required, and allow for short runs of high current, low-voltage cables, thereby reducing losses in the system and lowering costs. General purpose isolation transformers are suitable ...
Primary current: 0 mA - 2.5 mA
... Combined voltage current transformer. Power to be measured works with current–limiting resistance. Adopt permalloy core, epoxy resin encapsulated, PCB welding, mounting height 14mm. ...
Primary voltage: 7.2 kV - 36 kV
Frequency: 16.7, 50, 60 Hz
... High current transformers type AKQ are used in busbar systems with uninsulated primary conductors and are designed for long term use. Type AKQ current transformers ...
PFIFFNER International AG
Primary current: 0 A - 90 A
... supplier of transformers for high- current industrial processes like aluminum electrolysis or arc furnaces for steel and other metals. Furnace transformers for AC EAF ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group