- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Junction box with cable gland
Junction boxes with cable glands
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
flush-mount junction boxTSKS WDVS 185X140X88 AH50.200 K V2A
... well as a styrofoam cover (soiling protection during plastering). Suits for insertion of (perforations): –Round wire Ø8-10 mm –Round wire with plastic sheath Ø13 mm –HVI Conductors Ø20-27 mm –Flat strip 30x3.5 mm For ...
... Small, robust Ex e enclosure for distributing electrical energy IP66 degree of protection Equipped with 4 mantle terminals and 1 PE connection Available with plastic semi- glands or cable glands Functional ...
... level, including harsh environments, enables you to minimize the required deployment of marshalling cabinets, cable trays and master cables in your installation. Are you already using HIMatrix or HIMax systems? Then ...
Length / diameter: 95.5 mm - 143.5 mm
Width: 82.5 mm - 127.5 mm
Depth: 44 mm - 56 mm
... 44 mm; L 50 mm; C 50 mm; M 69 mm; B 82 mm; Cable gland size: PG11
Length / diameter: 60, 65, 70 mm
Width: 33, 40, 50 mm
Depth: 24 mm
... Integrated
junction
box consisting of
cable
glands and a terminal block.
Suitable for industrial facilities, power
cable joint, relay between motors and/or sensors.
3, ...
... 4B Group junction boxes are suitable for all applications demanding a junction box with ATEX, IECEx or CSA approvals. HOTBOX Junction box is a terminal ...
... JUNCTION BOXES FOR WEIGHING SYSTEMS Reference : JBOX Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment. o 4 or 6 inputs o Connection in 4 or 6 wires o ...
Width: 200 mm
Depth: 75 mm
... SMART JUNCTION BOX MONITORING LOAD CELL INTEGRITY Reference : JBOX-LCI Smart junction box is designed for parallel connecting of 2 to 4 load cells to an electronic device and for ...
Length / diameter: 149 mm
Width: 70 mm
Depth: 47 mm
... Small plastic junction box for 4 analogue load cells: • CAJA/4-PL (standard version) With gas dischargers to protect against atmospheric discharges External ground power outlet Double sealing gasket Possibility ...
SENSOCAR
Length / diameter: 149 mm
Width: 70 mm
Depth: 47 mm
... Small plastic junction box for 4 analogue load cells: • CAJA/4 PL-EX (ATEX version) With gas dischargers to protect against atmospheric discharges External ground power outlet Double sealing gasket Possibility ...
SENSOCAR
Length / diameter: 175, 250 mm
Width: 80 mm
Depth: 60 mm
... Aluminium junction box for 4 up to 16 analogue load cells: • CAJA/4-RA (4 load cells) • CAJA/6-RA (6 load cells) • CAJA/8-RA (8 load cells) • CAJA/10-RA (10 load cells) • CAJA/16-RA (16 load ...
SENSOCAR
... Terminals Type 1: 4 x Shirt terminal 4 mm² The 8118 series junction boxes are equipped according to the client specifications of different series terminals as well as plastic or metal cable glands; ...
... - REDUDED SWEET EX E E E CASE FOR ELECTRIC POWER DISTRIBUTION - Equipped with 4 terminals with shirt and 1 PE connection - Available with semi-fittings or plastic cable glands The 8102 series bypass ...
... outside of the lid to ensure a tight seal with the IP65/IP66 rating. GW... series enclosures are mainly used as junction boxes/for routing cables for analogue or digital signals and/or for control and monitoring associated ...
... 1. 3P product. 2. It is integrated type of cable glands and terminal block and easy to work. ...
... 1. 4P product. 2. It is integrated type of cable glands and terminal block and easy to work. Specification Temperature range : PBT : - 40 ~ + 100 Flammability Rating : V-0 ...
... 1. 6P product. 2. It is integrated type of cable glands and terminal block and easy to work. Specification Temperature range : PBT : - 40 ~ + 100 Flammability Rating : V-0 ...
Length / diameter: 58 mm - 175 mm
Width: 64, 80 mm
Depth: 34, 57 mm
... The versions of this sturdy polyamide enclosure with moulded-on Pg 11 cable gland reduce processing time and work • 5 sizes • Versions with or without screwing systems • Quick-release fastener versions • ...
... The SIGMA4 is an “intelligent” load cell cable junction box. During a test the system, the junction box and the indicator measures the load cell output per sensor and ...
... The load cell junction box is developed by Laumas Elettronica. It comes with a four-cells equalization board attached in the inside of an IP66 aluminum case. The casing of this junction ...
... particularly design to assure an easy access to direct grounded or cross bonded HV cable screen configurations. Fully submersible up to 1 m of water depth, the stainless steel enclosure provides excellent water and mechanical ...
Length / diameter: 144 mm
Width: 95 mm
Depth: 42 mm
... Terminal blocks pitch 5.08 OVERALL DIMENSIONS 144 mm x 95 mm x 42mm(l x h x p) with cable glands ...
NBC Elettronica Group Srl
... The CEM4-C is a connector for rapid connection to the 1006 tester for up to 4 load cells. These junction boxes have an ABS case with an IP 65 protection degree. ...
Pavone sistemi
Length / diameter: 110 mm
Width: 100 mm
Depth: 50 mm
... Protection class to EN 60 529 Voltage - 500 V Amperage 16 A Terminals/poles - 4-pole, 2,5 mm² Variations - on request ...
WISKA Hoppmann GmbH
Length / diameter: 43 mm
Width: 89 mm
Depth: 34 mm
... Junction Box, with protection class IP20, Nominal cross-section 2.5 mm², Ui=400V AC, certified according to VDE (DIN EN 60670-1/-22 (VDE 0606-1/-22)), Inserts with cable retention capacity, (8 Rear, 2 ...
Spelsberg
wall-mounted terminal boxZENITH-P series
... The ZENITH-P range comprises 17 sizes of enclosure manufactured in GRP glass reinforced polyester with 4 mm thickness. Polyester gives excellent mechanical strength and life expectancy: this material is highly resistant to contamination, ...
Length / diameter: 105 mm - 105 mm
Width: 105 mm - 105 mm
Depth: 80 mm - 80 mm
... Product overview
The Hub Series CBHUB-01-GY is a compact, IP66/IP67 rated
enclosure designed for IoT gateways,
junction boxes and DIN-rail compatible installations. Molded from UV-stable polycarbonate (UL94‑V0), ...
... AISI 316L stainless steel junction boxes Installation: zone 1/2/21/22 Classification: II 2 GD Execution: EEx-e II T5 IP66 Features: Body and Cover: S.S AISI 316L SP. 1.5 (mm). Silicon gasket. Screws: Stainless steel. ...
Length / diameter: 126.2 mm
Width: 102.8 mm
Depth: 35.2 mm
Length / diameter: 150 mm
Width: 150 mm
Depth: 90 mm
... • This product is corrosion-free, even in coastal areas or under unfavorable weather conditions, as it is made of plastic and does not have iron or other accessory materials that could be damaged. • Since contraction or expansion occurs simultaneously ...
DSE, Inc.
Length / diameter: 120 mm
Width: 120 mm
Depth: 90 mm
... This junction box ELAK-Ex-3 in conventional design is suitable for use in potentially explosive atmosphere in ac-cordance with Ex-guidelines 94/9/CE (ATEX 95). Moreover, the unit ELAK-Ex-3 covers a significantly wide ...
... provide a location for the outputs from several accelerometers to be combined and relayed to a remote data system with multicore cables. ...
... • Protects cable connections quickly and safely • For wet areas and underground installation • Easy to use • Connecting cables of different diameters • Cable diameter 6-13 mm • Replaces expensive ...
... The new Hybrid Splice Box is designed with a built-in optical fiber-electric cable for data and energy combination. It is available in a new version which has an SC-RJ coupling that allows single mode, ...
... External generator junction box with string fuse, overvoltage protection and DC disconnector. ...
... The junction boxe XAWF range Ex e in aluminum enclosures are designed for use in any environment where an explosive atmosphere may be present and are suitable for chemical agent environments, seawater corrosion resistance and extremes ...
... horizontally or connection of terminals, etc into threaded brass; higher intensity and more durable; Better waterproof and anti-corrosion performance; protect your instruments even under adverse environment; Note: ...
... the box. On the wall or board. Inlet and outlet holes: Kong Yin is already on the waterproof box, and customers can knock down at their own discretion. A hole and all supporting watertight ...
The PCX Series features enclosures suitable for applications in potentially flammable gas and dust. These units are built with an aluminium alloy or stainless steel construction that can resist explosion. They operate at a maximum of +55 °C and T6 (surface) ...
... MULTI- BOX Aluminium-Ex i junction boxes are conform to all requirements for installation fields where explosive concentrations of gases, steams and dusts can appear (zones 1 and as well as 21 and 22). MBA-Ex i ...
GEROS reserves the right to change at any time and without notice the characteristics of the products reported. Installation should be carried out by qualified staff in compliance with the current regulations regarding the installation of electrical equipment ...
... field device junction box for 2 components, with screw terminals the terminals of the junction box are integrated in an enclosure Double-insulated ...
... specifications
- Model: GBOX8D
- Product type: Digital junction box / sum box
- Maximum supported load cells: 8
- Cable glands: PG9 (suitable
... consistent weight readings.
Length / diameter: 199 mm
Width: 106 mm
... Connection of 4 to 10 load cells • Robust enclosure with cable glands sealed to IP67 • Easy trimming via resistors or potentiometers • Integrated surge protection devices • Strain ...
VPG Transducers - Vishay Precision Group
... LCT Junction Box/ Load cell accessory / for industry control Material: Platics or Stainless Steel Origin: Xiamen, China. ...
Width: 175 mm
Depth: 75 mm
... Junction Box for the TR-42 Temperature Control Relay - Plastic Box ABS. Protection degree IP65 dim. 175x125x75 mm - 3 Temperature Sensor PT100 Class B - 3 Levels with a sealed ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.