Primary current: 32 A - 1,600 A
... ELCB is not chosen to use in a special characteristic of the load, the special breaker is needed. On creating an isolation switch (DSN) by omitting the overcurrent tripping device of a MCCB, it can be used as a switching device with ...
Primary current: 16 A
VAC: 24 V - 690 V
Everything you need to make your application more efficient than ever: Commute easily power sources thanks to a changeover mechanism. Provide a real flexibility to fit with all type of installations thanks to a large choice of Pole units, Handles and ...
Primary current: 120 A - 240 A
... overview
The Powernet Guardian includes a load cut-off
switch (LCS) to isolate
safety loads from ordinary loads and a power isolation
switch (PIS) to isolate the DCDC from the
low-
voltage ...
Primary current: 32 A - 800 A
... 3KF switch disconnectors with fuses meet all the requirements for main control, EMERGENCY-STOP, and maintenance switches. They are designed to systematically prevent electrical accidents. For example, a suitable locking function during ...
Siemens Low-voltage – Power distribution
Primary current: 100, 200, 30, 400, 60 A
VAC: 208, 240, 480 V
... automatically disconnected before water is turned on by the fire safety system. Options Control power transformer with fuses and blocks Fire safety interface relay Key to test switch Pilot light ...
Littelfuse
Primary current: 160 A
VAC: 690 V
... indicator for switch door position - optional Safe on load connection/disconnection in accordance with IEC 60947-3 Applications House incoming units Meter distribution units Switch boards for industrial ...
Mersen - Electrical Power
Primary current: 40 A - 1,600 A
VAC: 500, 1,000, 690 V
... Installation : Inside and outside Main uses : Heavy industries (mines, quarries, sugar, cement, paper, iron and steel ...) Advantages : Resist to corrosion, acids, salts, organic solvents, lubricating oils and greases, fuel oils, U.V. rays : no discoloration, ...
Cefem Group
Primary current: 40 A - 800 A
VAC: 500 V - 1,000 V
... Installation : Inside and outside Main uses : Food and beverage, pharmaceutical industries with restrictive hygienic requirements. Advantages : A fully welded and robust enclosure which is 2 mm thick stainless steel. Our range design combines reliability ...
Cefem Group
... Installation : Safety enclosures for explosive environmentsare meant to be used in areas with explosion risk 1, 2, 21 and 22 "G" gas and "D" dust according to 2014/34/UE directive. They ensure emergency stop, load break for electrical ...
Cefem Group
Primary current: 400 A - 1,445 A
VAC: 690 V
... another essential system in modern electrical fittings- a switch disconnector system that is universal in the electrical world. Installations are everywhere in the switch and fuse blocks. The low ...
Primary current: 400 A - 1,000 A
VAC: 690 V
... Fuse- switch-disconnector system 203 (NH00-3) - according for DIN 43623 until IN 2000 A ...
Primary current: 160, 400, 630 A
VAC: 690 V
... Fuse- switch-disconnector system 202 (NH00-3) - according to DIN 43623 and IN 630 A ...
Primary current: 100 A - 500,000 A
VAC: 415 V - 33,000 V
... three-phase isolator switch to take your electrical infrastructure to new heights, bringing comfort and facilitating peak production. In this cutting-edge solution, efficiency and safety come together. Voltage ...
Primary current: 40, 25, 63 A
VDC: 600, 200, 1,000 V
DIGITAL ELECTRIC
Primary current: 20 A - 125 A
VAC: 400, 230 V
DIGITAL ELECTRIC
Primary current: 25 A
VAC: 240 V
DIGITAL ELECTRIC
Primary current: 25 A - 250 A
VAC: 400 V
At every control point and workplace where an emergency-off function is required, such devices must be present. They must mechanically snap into place automatically and be positioned where they can be easily reached.
ELEKTRA TAILFINGEN Schaltgeräte GmbH & Co. KG
Primary current: 25, 32 A
VAC: 400 V
... fall into the area of applicability of EC Low Voltage Directive 2006/95/EC. • On/Off switches • Single-phase starter switches • Toggle switches • Reversing switches • ...
ELEKTRA TAILFINGEN Schaltgeräte GmbH & Co. KG
Primary current: 630, 400 A
VAC: 400 V
... padlocks. The switches can also be supplied in 4-pole format with switchable neutral conductor and an auxiliary switch. DL series cam circuit breakers fulfil the requirements made by DIN EN 60204 Part 1, clause ...
ELEKTRA TAILFINGEN Schaltgeräte GmbH & Co. KG
Primary current: 2 A - 63 A
VAC: 400 V
... devices without active electronic components. They are able to switch on, direct and switch off currents under operation-relevant conditions. Fuse switch-disconnector switches do not ...
Primary current: 16 A - 160 A
VAC: 110 V - 690 V
... SIRCO M and MV are manually operated and modular multipolar load break switches. They make and break under load conditions and provide safety isolation for any low voltage circuit, particularly ...
SOCOMEC
Primary current: 250, 100, 200 A
VDC: 24 V
... Carling Technologies IP67 sealed BD-Series battery disconnect switch is designed to minimize battery drain, ensure maintenance personnel safety, and when used in conjunction with a padlock, provides vehicle theft protection. ...
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - Recessed area ...
BACO
Primary current: 25 A
VAC: 690 V
... Generalities The modular switch disconnectors of LAS series allow the breaking and the disconnecting on load of equipment on low voltage at nominal current from 16 A to 125A. Use The switch ...
ETI
Primary current: 16 A - 160 A
VAC: 400, 500, 690 V
... •Three-pole switch disconnector, direct operating version, 25A •Type of product: Switch disconnectors •Number of poles: 3 •Type of operating voltage: AC •IEC Conventional free air thermal current ...
LOVATO ELECTRIC
Primary current: 16 A - 160 A
... REFERENCE STANDARDS EN 60947-3 Low voltage switchgear and controlgear. Part 3: Switches disconnectors, switch-disconnectors and fuse-combination unit. EN 60529 Specification for ...
SCAME PARRE S.p.A.
Primary current: 100 A - 630 A
VAC: 690 V
... The three phase BS Fuse switch disconnector is for NH fuse-links. It has an available sizes from 000 to size 3 for board fixing and a model size 00 for mounting on 60 mm busbar system. It is equipped with IP20 for protection ...
Primary current: 12 A - 80 A
... . Fully manufactured in cast 304 stainless steel Dimensions (H x W x D): 165 mm x 120 mm x 117 mm Equipped with disconnect switch from WEG, Schneider or ABB brands and two cable glands M25 (14-17) ...
Primary current: 750 A
VAC: 1,500 V
... Sécheron XMS and BW high- voltage modular indoor disconnectors can be used as disconnectors or selectors on rail vehicles and in other industrial applications. Low ...
Primary current: 40, 25 A
VAC: 240, 400, 415 V
... 60947-3 Cable Area to Switch Terminal (only Cu) (mm2) / Bolt size - 1.5-16 Color - Yellow / Red Enclosure - M2 Enclosure Type - Polycarbonate IP Rating - 66 Operation - Front-operated Switch type - Load Break ...
KATKO
Primary current: 3 A - 32 A
VDC: 500, 600, 800, 1,000 V
... inverter. For isolation the PV array during system installation or any maintenance. The switch must be rated for system voltage (1.15 x string open circuit voltage Voc) and current (1.25 x string ...
Zhejiang Benyi Electrical Co.,ltd.
Primary current: 63 A
VAC: 240, 440 V
EMS Electro Mecanicals Systems
Primary current: 20 A
VAC: 690 V
... Panel mounting modular switch – disconnectors, are available from 20A to 125A in 3P – 3P+N. They are designed according to IEC/EN 60947-3 standard for use in civil and low voltage industrial ...
Telergon
... current carrying components made from glassfibre reinforced polyester - Switch contact with double break feature Schaltkontakt mit Doppelunterbrechung for high switching capacityn - Switch contact with pre and main contact ...
JEAN MÜLLER
Primary current: 40, 63, 80, 100 A
VAC: 750 V
Primary current: 20 A - 100 A
... sealing is a feature of the 'i- switch' range as is the ability to add a selection of auxiliary blocks providing additional contacts and a choice of Neutral assemblies. With the i- switch range comes an important safety ...
Craig & Derricott
Primary current: 10 A - 32 A
VAC: 500 V - 1,000 V
... The Santon X-type switch is of a modular design and enables a variety of construction combinations. Combinations of DC and AC in one switch are available, for example for simultaneously switching both sides of the inverter ...
Santon
Primary current: 0 A - 2,000 A
VAC: 4,000 V
VDC: 4,000 V
... Modular Multipole-Multiposition Off-Load Disconnector with Binary Control Option. The disconnectors are configurable assembling side by side poles, every one completely independent and controlled by a motor through ...
Primary current: 32 A - 100 A
VAC: 230 V - 400 V
... Application HL30-100 Disconnector switch is mainly used in AC 50Hz/60Hz, rated voltage not more than 400V in the power distribution and control loop.It is mainly as the main switch ...
Primary current: 0 A - 630 A
... Gave introduces a new range of NH fuse switch disconnectors characterised by its wide range of size, modularity and scope of accessories. Functions NH fuse switch disconnectors are used on low voltage ...
GAVE ELECTRO
Primary current: 100 A
VAC: 400, 230 V
... A reliable and trusted main isolating switch disconnect is crucial for ensuring the safety of electricians and maintenance engineers working on your aplication. The IMO range of isolating switch ...
IMO Precision Controls Limited
Primary current: 25, 40 A
VAC: 240, 415 V
... circuit. It is used as a main switch in low voltage distribution systems. It is easily to be assembled and works with the same series of compact circuit breakers together. · Only ...
WENZHOU RENA ELECTRIC CO.,LTD
Primary current: 16 A
VAC: 500 V
... entries in enclosure - 2 CAM layout - 1 Flush-mounting dimensions - - No. discs - - Function Apparatus Control - One way switches ATEX application zone - Zona/Zone 2, 21 and 22 Notified body ATEX - 0051 Certificate Number IECEx ...
Primary current: 40 A - 125 A
VAC: 230, 400 V
... loaded electrical circuits - As a main circuit breaker - Protection of heavy loaded electrical circuits Applications: - Industrial and administrative buildings Mounting: On a DIN rail Standards: ЕN60947-3 ...
Elmark
VDC: 750, 1,500, 3,000 V
... Segragated compartment for each Disconnector and/or Load Break Switch and for each cable incoming/outgoing. LBD DC Disconnecting Cubicles has a withdrawable execution on request. Segragated low voltage ...