- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Multi-strand cable
Multi-strand cables
Nominal voltage: 12 V - 230 V
Temperature: -40 °C - 80 °C
Cross-section: 0.75 mm²
... Data Operating Current per Contact (max.) - max. 8 A Cable Data Cable No. - 514 Material (Jacket) - PUR Outside-Ø - 5,7 ±0,2 mm Wire insulation - PP Wire colors - BN, BU, WH, BK No. ...
Nominal voltage: 800 V
Temperature: -30 °C - 70 °C
... For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Not approved for power and underground installation. DIN VDE 0815 ; directive 2014/35/EU RoHS 2011/65/EU EN 60332-1-2 ; EN ...
VOKA
Temperature: -40 °C - 60 °C
... signal cables, in interlocking and monitoring systems etc., unless the use of special cables for signalling technology (e.g. PZB / Indusi (inductive train protection) cables) is prescribed copper conductor, ...
Bayerische Kabelwerke
... specially designed as a cable for mobile use. Refer to "Typical Transmission Distance as per SMPTE Standard" on page72 for the length of the cable to be used. L-CHWS Series • Designed for mobile applications • ...
CANARE Electric
Temperature: 70 °C
Cross-section: 0.75, 1, 1.5 mm²
... Series, manufactured by Channel Well Technology, is a power cable designed for the transmission of electrical power. It has an operating temperature of 70℃ and a bare copper conductor. This power cable comes in various ...
Channel Well Technology Co.,Ltd.
Nominal voltage: 300 V
Temperature: 80 °C
... • Solid or strands, tinned or bare copper conductor 32-16AWG; • PVC insulation .comply with ROHS environmental standard • Uniform insulation thickness to ensure easy stripping and cutting; • Pass UL VW-1 ,CSA FT 1 and JQA -F-Mark ...
Yueqing RunEasy Electronic Technology Co.,Ltd.
Temperature: -40 °C - 90 °C
... SOLAR cable means flexible single cables specialty designed for wiring solar plants. SOLAR cables arc extremely robust and resist high mechanical load and abrasion. High temperature re-sistance and cxccllcnt ...
Temperature: -40 °C - 70 °C
... ZW-NOTKtsdD, W-YnOTKtsdD Universal fibre optic cable with multiple optical fibres in a loose tube, reinforced, flame retardant (a) CENTRAL STRENGTH MEMBER: dielectric FRP rod with or without PE jacket, (b) ...
Nominal voltage: 500 V
Temperature: -60 °C - 800 °C
Cross-section: 0.5 mm² - 95 mm²
... mica cable GN500-03 Applications: Electric heating, petrochemical, electrical and mechanical equipment, power plant, drying path, drying room, heating source for lighting, electric appliances etc TECHNICAL DATA Fire resistant ...
Jiangsu Silver&Tin Thread Hi-Temp Wire And Cables
Temperature: 105 °C - 1,200 °C
... steel shields for applications where more strength is needed. Multiwire cable with pairs from 2 to 50, numbered with individual or group shields. High temperature extension wire with metallic sheath and mineral ...
Temperature: -10 °C - 105 °C
... bare copper drain wire Twisted cores & screened construction for reduced electrical noise Conductors PVC insulated and twisted together, aluminium Mylar® tape screen & drain wire, overall PVC sheath General purpose cable ...
Labfacility Limited
Nominal voltage: 500, 300 V
Temperature: 90 °C
Cross-section: 0.75 mm² - 1 mm²
... dielectric strength, and can withstand the bending stress and other mechanical stresses incurred during normal usage. 3.The cable/ wire rod is of great weather resistance and oil resistance, and is suitable for application ...
Guangdong Rifeng Cable Company
Temperature: -30 °C - 70 °C
... 8544200000 Application: Local Communication Cable, Coaxial Cable, RF Cable Cover Material: PVC/LSZH Material Shape: Round Wire Wire Core Material: BC/CCS Model: ...
Jiangsu Elesun Cable Co., Ltd.
... 1.0 Pitch, PVC, Gray Color Overview/Description Flat Cable which can be soldered or inserted to achieve board to board interconnections. These flat flexible cable with round pins are made up of tin plated copper insulated ...
... Specification: 3x0.6 Conductor: Tinned copper Inner jacket: PE Outer jacket;PUR Breaking strength: 2000KG ...
Derulcable (Shanghai) Co., Ltd
Cross-section: 2.5 mm² - 120 mm²
Length: 0.2 m - 0.5 m
... H1Z2Z2-K cables; are suitable for UV rays, ozone, bad weather conditions and are made of cross-linked material that does not contain halogen gases. They are resistant to fire and do not transmit flame. Electrolyticly tinned, thin ...
Ege Kablo Endustri Malz. San. ve Tic. A.S.
Nominal voltage: 1,000 V
Temperature: -60 °C - 80 °C
... The cable SKD02-T is a system cable for connecting digital camera systems and was particularly developed to be used in hazardous areas. It meets the requirements for cables and wires according to DIN ...
SAMCON Prozessleittechnik
Nominal voltage: 1,500 V
Temperature: -40 °C - 80 °C
... Multicore cables, PVC Conductor: bare copper acc. to EN 13602 Stranding: 14x0,15mm Core Isulation: PVC acc. VDE 0207 / EN 50363-3 Color code cores: DIN 47100 Outer sheath: PVC acc. to VDE 0207 / EN 50363-4 Jacket Colour: RAL 7001 ...
MediKabel GmbH
... coaxial cable for the frequency range up to 6 GHz. Due to the low attenuation and the great flexibility, this cable can be used for many applications in communications and radio technology. The inner conductor of the ...
... CUSTOM-MADE PRODUCTION: Formats and structures of cables made on request. Know-how: - Notching - Fitting - Stripping + crimping ...
Nominal voltage: 30 V
Temperature: -40 °C - 80 °C
Length: 1.5 m
... network cables for customers base on the application requirements ● Thick gold-plated RJ45 plug with good copper alloy conductor ensure above 500 times mating life ● Multi stranded copper wires improve ...
Cableforce Electronics Co., Limited
Temperature: -5 °C - 70 °C
... Universal cable A/I-DQ(ZN)BH 1x12E9/125 OS2 FO-Cab A/I-DQ(ZN)BH 1x12 OS2 Dca Universal cable A/I-DQ(ZN)BH 1x12E9/125 OS2 12x Singlemode OS2 yellow 2000 m Dca s2 d1 a1 ...
Nominal voltage: 300, 500 V
Temperature: -60 °C - 250 °C
... feature 1, rated voltage: 300/500V 2, working temperature: -60 ~ +200 ° C / 250 ° C 3. Conductor: stranded tinned or silver plated copper wire 4. Insulation: FEP (200 ° C) or PFA (250 ° C) Teflon 5, protective ...
Shanghai Shenyuan High Temperature wire Co., Ltd
Nominal voltage: 600 V
Temperature: -40 °C - 105 °C
... Application: Used for Electric Vehicle fast charging Structure: Conductor: Strands of fine twisted bare into bundles,TypeⅤ and Type Ⅳ conductors in compliance with IEC60228 Insulation:Optional, Available both TPE and PVC Cores:wire ...
Hangzhou Jiayuan Industrial Co., Ltd.
Nominal voltage: 25, 60 V
Cross-section: 0.22 mm² - 8 mm²
... AUTO Cable Item: TXL CABLE Standard: SAEJ 1128-2000 Voltage: 60V DC, 25V AC Conductor: Cu/ TC/ CCA Material:XLPE Section: 24AWG—6AWG Application:Using in electrical system of vehicles ...
Huzhou Permanent Cable Co., Ltd.
Nominal voltage: 7, 6, 4 kV
Temperature: 90 °C
Cross-section: 25 mm² - 1,000 mm²
... Application: This cable is used for urban networks. It can be installed aerially, in conduit, on open trays and in underground ducts Operating temperature: 90℃ Voltage rating: 3.6/6(7.2)KV Construction: ...
Nominal voltage: 10 kV
Temperature: -65 °C - 250 °C
... PEEK INSULATED WIRE, RADIATION RESISTANT, MULTISTRAND 0.35mm, LENGTH 10M Kapton Wires and Accessories Radiation Resistant Specifications Disruptive Voltage - > 10KV DC Voltage Rating - 4KV DC in vacuum Temperature Range - -65°C to 250°C (-200°C ...
Allectra.com
Nominal voltage: 60, 600 V
Temperature: -40 °C - 105 °C
Cross-section: 1.5, 2.5, 0.5, 0.75, 1 mm²
... Unshielded Cables for Road Hazardous Goods Transports (ADR) STANDARD USE: Cables for electric cabling and systems for trailers and semi-trailers, constructed especially for the transports of hazardous ...
Elettronica Conduttori
Nominal voltage: 0 kV - 45 kV
Temperature: 90 °C
Cross-section: 35 mm² - 500 mm²
... Power cable, single-core, copper or aluminium conductor, unarmoured, sheathed TCVN 5935, IEC 60502-2 Construction: Cu(Al)/XLPE/CTS/PVC Conductor: Annealed plain copper or aluminium (class 2, compacted circular) Conductor screen ...
Thinh Phat Cables Joint Stock Company
Nominal voltage: 750, 450 V
Temperature: 70, 160 °C
Cross-section: 1.5 mm² - 95 mm²
... Flat cable with fine-stranded copper conductor, PVC insulared, PVC sheat. ...
IZAYTECH
Temperature: -40 °C - 200 °C
... environments Description: Oil field armored cable was constructed of the inner stainless steel seamless tube, field with water-blocking gel between the bare fiber and the seamless tube, and strand with outer wire ...
Nominal voltage: 300, 500 V
Temperature: -40 °C - 90 °C
... section and class as the insulated conductors in the 2-, 3- and 4-core cables. Drain wire of 0.5 mm2 tinned copper conductor is provided in cables with more than 4 conductors. Outer sheath LSZH thermoplastic ...
Cavicel
Cross-section: 0.75 mm² - 500 mm²
... The copper cable is the essential equipment for any installation of electrical equipment. The use of wires with diameters of 0.10mm and 0.25 makes it a flexible cable. The properties of copper make it an ideal material ...
TESORAX
Draka offers a wide selection of power and signal wire, including shielded pairs, door lock wire, THHN and TEW, coax, UTP and more.
Nominal voltage: 1,500, 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 35 mm²
... Photovoltaic DC Cable Product Certification TÜV Rheinland 2PfG 1169 Testing Standard Cold bending test: EN 60811-1-4 Vertical burning test: EN 60332-1-2 2) SI-62930 IEC131 Dual-core Photovoltaic Cable Product ...
... Extra flexible aluminum cable in vinyl sheath for earthing and short-circuiting Extra flexible braided aluminum multibruns cables in transparent vinyl sheath with CATU marking and section. Delivered by the meter ...
... Vinyl sheathed copper cable for MALT/CC Application : Earthing and short-circuiting cables. Features : Material : Copper with insulating sheath in extra flexible PVC ST11 grade. Transparent insulating ...
... Application : - Earthing and short-circuiting cables. Features : - Conform to IEC 61230. - Material: multi-stranded copper with extra flexible silicone insulation. - Operating temperatures: -40°C to +60°C. - ...
Nominal voltage: 0 V - 1,000 V
Temperature: 70 °C - 1,200 °C
Cross-section: 0.1 mm² - 2.5 mm²
... Construction : Single Pair / Multi Pair Voltage Grade : Upto 1.1 KV Conductor : ABC, NPC, TPC, SPC, Ni Conductor Size : 0.50, 0.75, 1.0, 1.5, 2.5 Sq.mm or as per requirement Conductor Stranding : Solid or Multi ...
Cross-section: 4 mm²
... other chemicals. In contrast to conventional copper cables, the stranded steel wire does not break due to continuous daily use. ...
Temperature: -40 °C - 200 °C
... Signal
cable connect the sensor and the preamplifier and it can shield the sensor from electromagnetic interference.
Features
Solid polytetrafluoroethylene insulated coaxial
cables
...
Temperature: -20 °C - 80 °C
... Coaxial cable is used for transmitting the AE signals, and as the cable connecting the preamplifier and the acquisition instrument, which has wideband of frequency and excellent noise suppression characteristics. Features: Radio ...
Nominal voltage: 10 kV - 36 kV
Cross-section: 50 mm² - 400 mm²
...
·IEC 60502-4
Cable accessories
·IEC 60502-2 Power
cables with extruded insulation
·IEC 60840 High voltage
cables
·IEEE 48
Cable terminations
·ICEA standards North American ...
Cross-section: 5.89 mm² - 38.7 mm²
... Alloy
Strands
·Made from high-strength aluminum alloy (commonly 6201-T81)
·Multiple wires
stranded concentrically
·No steel reinforcement
Typical constructions:
·7
strands
·19
strands
·37 ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.