- Detection - Measurement >
- Temperature and Humidity Measurements >
- Reference temperature sensor
Reference temperature sensors
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Temperature: -200 °C - 670 °C
Probe diameter: 7 mm
... rate: < 0.006 °C/100 hours at max
temperature (typically < 0.003 °C)
Self-heating at TPW: < 0.002 °C under 1 mA
Reproducibility: ± 0.0015 °C or better
R_TPW drift after
thermal cycling: < 0.001 °C
Pt
sensor ...
Temperature: -50 °C - 200 °C
Process pressure: 40 bar
Response time: 25 ms
... Immersion temperature sensor 100 mm, Pt100, direct immersion With connection head made of die-cast aluminium. No protection pocket required. Technical Specifications Immersion length 100 mm Analog output, ...
Temperature: 0 °C - 50 °C
... The CO2 Duct Probe with Analog Temperature Sensor uses a completely new CO2 sensing technology. The silicon based CARBOCAP® sensor provides stability and reliability. The CARBOCAP sensor ...
Temperature: -200 °C - 660 °C
Probe diameter: 6.4 mm
... accurate and extremely stable temperature sensor and is aimed to be used as a reference sensor in the most demanding temperature calibrations. The RPRT is available ...
Beamex
Temperature: -50 °C - 400 °C
Probe diameter: 3 mm - 3 mm
Response time: 5 s
... approximation method). Highest accuracy is achieved during calibration by a multi-point adjustment of the temperature sensor. The digital sensor is supplied with a DAkkS calibration ...
Temperature: -40 °C - 110 °C
... or expensive calibration processes necessary Description The redundant temperature sensor has two measuring elements. The reference comparison between the two measuring resistors ...
Temperature: -200 °C - 670 °C
... . Suitable for use as working standards in dry blocks and liquid baths or as high accuracy probes for our range of true temperature indicators. All the thermometers are metal sheathed and both less fragile and more affordable than ...
AOIP
Temperature: -200 °C - 670 °C
... The 909 economically-priced Standard Platinum Resistance Thermometers are the workhorse of calibration laboratories all over the world. The wide temperature ranges from -200°C to 670°C and economic pricing make these ...
AOIP
Temperature: 0 °C - 1,000 °C
... The 96178 is a High Temperature Standard Platinum Resistance Thermometer for use from 0°C to 1000°C. It has a unique design and is made of ultra-high purity Quartz which allows the thermometers to offer extremely high stability. Key ...
AOIP
Temperature: -40 °C - 80 °C
Probe diameter: 2.2 mm
Response time: 30,000 ms
... >
Temperature: -90 °C - 180 °C
Response time: 30,000 ms - 30,000 ms
... Short description
Digital
temperature
probe used as a
reference standard for the
calibration of data loggers and probes. Designed for metrological monitoring where tight MPE ...
Temperature: -50 °C - 200 °C
Probe diameter: 2.2 mm - 2.2 mm
Response time: 30,000 ms - 30,000 ms
... li>
Temperature: -100 °C - 700 °C
... The STS Reference Sensors are Pt100 reference probes used as the reference instrument to verify true temperature in any type of hand-held, liquid bath, or dry-block calibrator. ...
Temperature: 0 °C - 1,300 °C
... The AM1210 Reference Standard Type S Thermocouple is made from reference grade platinum and platinum-rhodium alloy. It covers a temperature range from 0°C to 1300°C with a short term stability of <0.2°C ...
Additel Corporation
Temperature: -40 °C - 650 °C
... The standard temperature sensors are mainly used with temperature calibrators to make it easier to calibrate a temperature sensor by comparing the value reported by the ...
GIUSSANI SRL
Temperature: 1,100 °C - 1,554 °C
... calibration of thermocouples. Three types of S type thermocouple, R type thermocouple, and B type thermocouple are available. The temperature-thermal EMF table is prepared on request. ...
Temperature: -40 °C - 85 °C
... IO-Link®, local temperature sensor reference design that provides excellent temperature accuracy from -40°C to +85°C. Built in an industrial form factor, the design makes use of the Maxim ...
Temperature: -40 °C - 125 °C
Process pressure: 0 bar - 1,000 bar
Response time: 1 ms
... while its temperature output from the integrated temperature sensor is either resistance change in Ohms of a Pt100, or mV signal of a thermal diode. This output signal from the temperature ...
Temperature: -40 °C - 85 °C
Response time: 1 s
... Analog signal temperature sensor has two types: voltage output (three-wire system) and current output (two-wire system). The sensor has excellent quality, fast response, strong anti-interference ability ...
the best suppliers