- Detection - Measurement >
- Temperature and Humidity Measurements >
- Thermocouple
Thermocouples
Temperature: -40 °C - 800 °C
... is to be used as a replaceable part of thermocouple assembly with design suitable to such an action. In this way you may perform very quick replacement of faulty sensor. Connection wires constitutes a thermocouple beginning ...
Alf-Sensor
Temperature: -50 °C - 150 °C
Probe diameter: 8 mm
... IO-Link Smart Temperature Sensor - High Precision Temperature Monitoring Solution The TBH series is a high-precision smart temperature sensor featuring a 4-digit digital display and IO-Link communication capabilities. It supports various signal types, ...
Sentinel Electronics
Temperature: -200 °C - 1,500 °C
... platinum-iridium 10-platinum thermocouple for the determination of second-class standard platinum-iridium 10-platinum thermocouple; second-class standard platinum-iridium 10-platinum thermocouple for ...
Temperature: -270 °C - 1,820 °C
Probe diameter: 8, 6 mm
Response time: 1 ms - 60 ms
Thermocouples are based on the thermoelectric effect and are characterized by their robust design and an excellent volume/temperature range relationship. Please take into account, however, the higher temperature tolerance classes and ...
Temperature: -200 °C - 350 °C
... Thermocouples are a widely used type of temperature sensor formeasurement and control and can also be used to convert a temperature gradient into electricity. A thermocouple consists of two conductors of different materials(usually ...
Temperature: -130 °C - 760 °C
... recommended). A maximum of eight PT450 Thermocouple Probes may be connected to one XR5-SE Data Logger . Additional Pace sensors or voltage signals may also be connected to the same XR5-SE Data Logger. J Type Thermocouple May ...
Pace Scientific
Temperature: 0 °C - 250 °C
Probe diameter: 9 mm
Spectral range: 5.5 µm - 16 µm
... • Flexible and customizable • Small size, easy installment and use • High sensitvity • Non-contact temperature sensor • Small size sensor head (18 mm) • Output 0-5V, 0-10V, 4-20mA, UART/RS232 • Repeatability error < 0,1°C (0.18°F) • Interchangeability ...
... Sensor Installs Without Removing Temperature Transmitter Enclosure or Thermowell Components: The WORM® flexible RTD and thermocouple temperature sensors for thermowell Temperature Assemblies replace restrictive, straight sensor probes ...
Temperature: -200 °C - 400 °C
... to measure ambient temperature and a universal input that can be configured for any of the following inputs: Pt 100 Thermocouple Types J, K, T, R, S 4-20 mA - Scaled in engineering units Voltage Contact Closure The enclosure ...
Temperature: -40 °C - 100 °C
... Food Simulant Temperature Probe. This polypropylene food simulant probe is designed for use in food storage and refrigeration applications. When fitted to a data logger the probe simulates the actual temperature of foods in chill cabinets and similar ...
Temperature: 400 °C
... Conventional insulation thermocouples and resistance temperature detectors Conventional insulation thermocouples (type "J" and "K") and resistance temperature detectors (PT100) are commonly used when ...
CREI S.r.l.
Temperature: -50 °C - 400 °C
... Resistance thermometer class A or B, thermocouple 1 or 2 class - 2-wire, 3-wire or 4-wire circuit - Short response times - Customer – specific bush lengths and diameter Application possibilities Push-in RTD or thermocouple ...
JSC Viltrus
Temperature: -100 °C - 900 °C
... Flexible probe, type K Temperature range: -100 to 900°C/-148 to 1652°F Dimensions: 225 X 4.8mm ...
MTP Instruments Inc
Temperature: -50 °C - 200 °C
... TMC-K-A-5 Type-K thermocouple probe USD$19.99 Length: - 1.5 m (5 ft) - Material: - Teflon Description TMC-K-A-5: Type-K thermocouple probe. Type-K bare welded point thermocouple for fast ...
Temperature: -40 °C - 60 °C
... DAQ low temperature temperature sensor ( thermocouple type T support) Real-time temperature measurement and transmission (2CH) in a non-contact manner · Universal thermocouple T type support Temperature measurement ...
Dekist
Temperature: -40 °C - 65 °C
SenSpot™ provides an easy to install, scalable solution for distributed structural integrity monitoring. SenSpot™ Temperature Sensor uses Resensys’s proprietary technology for reliable and accurate measurement, large-scale sensing, wireless synchronization ...
Temperature: 0 °C - 140 °C
The T100 Series temperature transducers, based on high quality thermal resistances, are characterized by their high stability and precision and can be easily installed to record, control and display the real-time temperature value for gaseous fluids, ...
Temperature: -200 °C - 2,320 °C
... EMF characteristics of the thermocouples in this catalog conform to DIN 43710 and IEC 60584 standards. In order to increase the life-span of thermocouples the materials for the thermocouple, element ...
Elimko Elektronik Imalat ve Kontrol
... Flexible Thermocouples and Extension Wire Assemblies A14B Series NOTES: When ordering, specify Part No. and fill in the four letter blocks. For stainless steel over braid add the suffix SS to the Part No. Example: ...
Nanmac Corporation
... Temperature controllers with bayonet fitting : female bayonet, bayonet with internal lugs, bayonet with external lugs. Angular Temperature Controllers Surface Temperature Controllers Straight Temperature Controllers Material Temperature Controllers Screw ...
Temperature: 0 °C - 1,260 °C
Probe diameter: 0.3 mm - 12.7 mm
... Type K is the most common thermocouple cable with economic cost, it has a good resistance against oxidation and can be recommended for oxidizing and inert atmospheres. The temperature range of type K is 0..1260°C. SICC is one of the ...
Super Instrument Ltd
Temperature: 100, 80 °C
Probe diameter: 22 mm
... Our rotting control system COMPO-matic® is a complete measuring- and control-system to optimize the rotting factors oxygen and temperature during the rotting process. The single components are: By means of only one measuring probe that makes over the ...
Temperature: -40 °C - 60 °C
... DUOS UTEMP - WIRELESS TRANSMITTER Multiple temperature inputs (RTD, Thermocouples, linear Ohm and linear mV) Discrete digital input Internal and external temperature Up to 4 Km communication distance (LoS) with AES-128 bit encription Battery ...
TEKON ELECTRONICS
... Versatility of use, c0st0 c0ntenut0.Taratura: J (Fe-C0), 0cchiell0 in 0tt0ne Cav0 length in meters. 1.C0mp0st0 from c0ndutt0ri ilessibili is0lati C0n braid elettr0vetr0 silic0ne ric0perta C0n copper braid stagnat0. M0lla crease in0x mm.35.Giunt0 cald0: ...
Temperature: 1,200 °F
... engines. Durex Industries custom designs and manufactures diesel engine temperature sensors for OEM applications. Our RTDs, Thermocouples, IC sensors and Thermistors are specifically designed to perform in rugged harsh environments. To ...
Durex Industries
Temperature: -20 °C - 80 °C
... Temperature probes with NiCr-Ni component The stainless steel temperature probe with NiCr-Ni component is available for a variety of applications in a range of lengths. The 4009, 4020 and 4030 models of the probes are perfect for composting applications. ...
Temperature: -50 °C - 1,300 °C
... between the thermocouple and the IR source isn't perfect and the reading from the thermocouple can be between 50 and 100°C lower. E.g. If the source is operating at 975°C, the thermocouple will read ...
Temperature: -20 °C - 70 °C
Process pressure: 0 Pa - 5,000 Pa
... compensation for cold. Safe and reliable life. Site parameter setting,facilitate user With Hart or not FDWR series armored thermocouples use homogeneous conductors (A electrode and B electrode) to form a closed loop. When the two ...
... determining the style of thermocouple when manufactured. The main determining factors of what type thermocouple needs to be used in a application is temperature, environment, response time and accuracy. The junction of ...
Temperature: -18 °C - 150 °C
... Temperature gauge with digital display, no external power supply Temperature sensor with digital display Optionally with switch output and external power supply Process connections for pharmaceutical applications 3A conform ...
Temperature: -200 °C - 800 °C
Probe diameter: 0 mm - 11 mm
... Various indexing thermocouples are available Can provide single or double thermocouple Junction box type B, BUZ, BUZH, BBK Integral temperature transmitter is optional Used to measure the temperature of liquid or ...
Zias(Shanghai) IOT Technology Co.,Ltd
Temperature: -20 °C - 300 °C
Response time: 5 s - 10 s
... Quick Features High temperature measurement probe Wireless Options Available Flexible Power Options (DC, Battery, USB) Display Available Audible Alarm Configurable reporting interval, alarm, etc Customized Options ...
Temperature: -40 °C - 1,030 °C
... • Usable up to 80°C ambient temperature without cooling • Several outputs selectable: 0-10 V or 0-5 V free scalable or thermocouple, alarm output or digital output ...
... The Rabourdini Industrie offers this Type J thermocouple temperature probe with reference number 6935 for utilization as hot-runner manifold block. ...
Temperature: -200 °C - 1,600 °C
... Features : Small size, suitable for lots of applications; 2 wires, output 4~20mA DC; High precision measurements; Thermocouple for measurement, no need compensating cables , reduce costs Explosion-proof Rate: dIIBT4; IP ...
Temperature: 800 °C
... Type J and K thermocouples allow temperatures of up to 800 °C to be measured. ...
Temperature: -180 °C - 300 °C
... PTFE Encapsulated temperature probes with metal core. The probes come either J or K type thermocouples. All probes are 7mm OD and have an operating range from -180 to 300 degrees C. The probe lengths and lead lengths vary to fit your ...
Temperature: -10 °C - 70 °C
The RTP1 temperature probe significantly improves the flexibility for part temperature measurement on a CMM. It can be automatically interchanged with any other REVO probe at any stage in a part or batch measuring sequence. This enables users to automatically ...
thermocoupleSonde de température thermocouple
Temperature: -200 °C - 1,600 °C
Probe diameter: 0 mm - 8 mm
... THERMOCOUPLE TEMPERATURE PROBE FOR EXTREME INDUSTRIAL ENVIRONMENTS
A ROBUST SOLUTION FOR RELIABLE HIGH TEMPERATURE MEASUREMENT
The Fuji Electric
thermocouple temperature probe ...
Temperature: -100 °C - 300 °C
... Product description Thermocouple, 1 pair type K: Chromel (+)/Alumel (-), (type C, E, J on request) 2 conductors made of copper (nickel on request) Includes atmosphere sided miniature plug for thermocouple ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.