OverviewThe SOBA HR HY float level switch is designed for automatic pump control and level regulation in aggressive or corrosive liquids. It features a press‑vulcanised HR HY (Hypalon) double envelope with a biconical shape, a changeover contact (COM/NO/NC) and an adjustable 250 g resin ballast on the cable for fine tuning of the rotation point and operation across a wide density range.
OperationThe device operates by a tipping principle: the float rises and falls with the liquid level and actuates the integrated mechanical switch when the preset position is reached. The 3‑wire cable (COM, NO, NC) allows selection of filling or draining mode at wiring. Two identical floats can be used together to control minimum and maximum tank levels.
Key features and advantages- Press‑vulcanised HR HY (Hypalon) biconical double envelope for resistance to aggressive liquids.
- Adjustable resin ballast (250 g) on the cable to set the switching point.
- Changeover contact NO/NC (3‑wire: COM, NO, NC) for direct control or via relay.
- Hydrodynamic shape reduces debris accumulation and maintenance needs.
- Suitable for a wide range of fluid densities.
- IP68 protection; designed and manufactured in France.
Usage modes- Drain mode: switch stops pump to protect equipment when tank is empty.
- Fill mode: switch activates pump to fill tank when float is low (NC wiring).
- High/low alarm functions for overfill protection or dry‑run prevention.
Electrical characteristics (excerpt)Supply examples: 12, 24, 48 VAC/VDC; 250 VAC/VDC 50/60 Hz. Switching capacity: 16 (6) A (16 A resistive; 6 A inductive). Example DC ratings: 48 V — resistive 1.5 A / inductive 0.8 A; 12 V — 100 mA; 24 V — 10 mA.
Installation and useThe ballast is adjustable on the cable: moving the weight changes the level differential required to actuate the switch (greater distance weight/float increases the level difference). Indicative values: Y min = 10 cm -> X 25–30 cm; Y max = 30 cm -> X 45–50 cm. Cable can be supplied to custom length to avoid inappropriate splices. The float should be suspended by the cable sheath (recommended accessory: FIXCAB). External electrical connections must be made in a sealed junction box located outside the tank.
Technical specifications- Switching angle: +/- 25°
- Admissible fluid density: 0.70 to 1.10 kg/dm³
- Maximum operating pressure: 4 bar
- Maximum temperature: 90 °C
- Protection rating: IP68
- Envelope: biconical Hypalon (HR HY)
- Cable: 3 conductors, 1 mm²
- Float weight (without cable): 295 g
- Ballast: 250 g charged resin (adjustable)
- Standard cable lengths: on request
NotesNot recommended for highly turbulent aggressive liquids. For installations in hazardous areas choose the ATEX certified model SOBA EX.