Mass flow rate

Max.: 13,363 kg/h
(29,460.37 lb/h)

Min.: 8 kg/h
(17.64 lb/h)

Volumetric flow rate

Max.: 4,210 m³/h
(148,674.7 ft³/h)

Min.: 2 m³/h
(70.6 ft³/h)

Process temperature

Max.: 300 °C
(572 °F)

Min.: 0 °C
(32 °F)

Process pressure

Max.: 35,000,000 Pa
(5,076.32 psi)

Min.: 10,100 Pa
(1.46 psi)

Precision

0.2 %, 0.3 %

Description

STEAMcube is a special-purpose flowmeter developed for the measurement of saturated steam. It has a built-in pressure compensation function and is capable of accurate mass flow rate measurement even when there are pressure fluctuations. The required upstream straight pipe length is extremely short, so this flowmeter can be installed in places where it was previously impossible to put a flowmeter. Its small size also facilitates a more compact design of the overall equipment. Handles changes in steam conditions during mass flow rate measurement. Short upstream straight pipe length is ideal for all types of piping layouts Handles low flow rates without an interruption in output. Low pressure loss and high range coverage overturn conventional limits on differential type flowmeters. Simultaneous analog and pulse output Dual sensors The sensors used in STEAMcube simultaneously measure differential and static pressure, allowing the successful calculation of the mass flow rate output. The static sensor compensates for changes in density, which is important when measuring the flow rate of steam; and STEAMcube has an internal steam table for calculation of steam temperature from a static pressure value at a saturated steam pressure. Since the dual sensors are more responsive than the temperature compensation method ordinarily used in vortex flowmeters, and because they respond to pressure fluctuations caused by opening/closing the steam trap, they provide a more accurate output. Self water sealed structure Even a sturdy transmitter becomes hot if it makes direct contact with steam. In the self water sealed structure, drained steam protects the transmitter (diaphragm).

Catalogs

No catalogs are available for this product.

See all of Azbil‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ACHEMA 2024
ACHEMA 2024

10-14 Jun 2024 Frankfurt am Main (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.