Portable combustion analyzer MS700-FG
O2 : 0 to 25%CO : 0 to 10 000 ppmNO : 0 to 5 000 ppm

Portable combustion analyzer - MS700-FG - Beijing Zetron Technology Co., Ltd. - O2 : 0 to 25% / CO : 0 to 10 000 ppm / NO : 0 to 5 000 ppm
Portable combustion analyzer - MS700-FG - Beijing Zetron Technology Co., Ltd. - O2 : 0 to 25% / CO : 0 to 10 000 ppm / NO : 0 to 5 000 ppm
Portable combustion analyzer - MS700-FG - Beijing Zetron Technology Co., Ltd. - O2 : 0 to 25% / CO : 0 to 10 000 ppm / NO : 0 to 5 000 ppm - image - 2
Portable combustion analyzer - MS700-FG - Beijing Zetron Technology Co., Ltd. - O2 : 0 to 25% / CO : 0 to 10 000 ppm / NO : 0 to 5 000 ppm - image - 3
Portable combustion analyzer - MS700-FG - Beijing Zetron Technology Co., Ltd. - O2 : 0 to 25% / CO : 0 to 10 000 ppm / NO : 0 to 5 000 ppm - image - 4
Add to favorites
Compare this product

Characteristics

Type
portable
Functions
calculated CO2, combustion efficiency, air temperature, CO : 0 to 10 000 ppm, flue temperature, draw / pressure, SO2 : 0 to 5 000 ppm, O2, O2 : 0 to 25%, NO : 0 to 5 000 ppm, H2S : 0 to 50 ppm, NO2 : 0 to 1 000 ppm
Fuels
oil, wood, coal

Description

Product overview
The MS700-FG portable flue gas analyzer is a handheld, industrial-grade multigas instrument designed for on-site stack and combustion monitoring. It supports up to seven measurement parameters with optional NDIR and electrochemical sensors, measures flue gas and ambient temperatures, flow/velocity and pressure, and automatically computes CO2, excess air coefficient, combustion efficiency and heat loss.

Applications
  • Commissioning, tuning and maintenance of industrial boilers and burners
  • Power plants, heating stations, steam and thermal oil boilers
  • Emission monitoring and environmental compliance testing
  • On-site stack gas composition analysis and inspections
  • Combustion optimization and energy efficiency assessments
  • Process gas analysis in chemical, petrochemical and metallurgical installations
  • Monitoring for engines, turbines, CHP and marine diesel/gas systems
  • Waste incineration, biomass combustion and cement/glass production furnaces
  • Safety inspections and leak detection in confined gas systems


Features
  • Handheld, compact design supporting up to 7 parameters (O2, CO, NO, NO2, SO2, H2S, NH3, CO2 (NDIR), N2O (NDIR), CH4 (NDIR) etc.)
  • Cross-interference compensation and dual-range sensor option for instant high/low switching
  • On-site sensor replacement and calibration by standard gas without factory return
  • Automatic sensor detection and zero calibration at power-on
  • Three-stage sample treatment: optional Peltier cooling, automatic water vapor separator and high-end water cut-off filter
  • Built-in satellite positioning/timestamp (Beidou) for traceable data and remote monitoring via mobile phone
  • Optional Bluetooth printer; data logging with encryption, memory card slot and Type-C interface
  • Rechargeable lithium battery for up to ~8 hours operation; chargeable during use; onboard diagnostics for real-time instrument status


Measurement parameters
O2 | 0~25/100 Vol.% | ±0.2 Vol.% | 0.01 Vol.%
CO (T90≤10s) | 0~5000/10000 ppm | ±5 ppm (0~100 ppm); ±5% (≥100 ppm) | 0.1 ppm
CO (H2 compensation) | 0~2000 ppm | ±5 ppm (0~100 ppm); ±5% (≥100 ppm) | 0.1 ppm
CO low (T90≤10s) | 0~500 ppm | see CO accuracy | 0.1 ppm
SO2 (T90≤20s) | 0~5000 ppm | ±3 ppm (0~60 ppm); ±5% (≥60 ppm) | 0.1 ppm
SO2 low (T90≤20s) | 0~300 ppm | ±3 ppm (0~60 ppm); ±5% (≥60 ppm) | 0.1 ppm
NO (T90≤10s) | 0~5000 ppm | ±5 ppm (<100 ppm); ±5% (≥100 ppm) | 0.1 ppm
NO low (T90≤10s) | 0~300 ppm | ±5 ppm (<100 ppm); ±5% (≥100 ppm) | 0.1 ppm
NO2 (T90≤30s) | 0~1000 ppm | ±5 ppm (<100 ppm); ±5% (≥100 ppm) | 0.1 ppm
NO2 low (T90≤30s) | 0~100 ppm | ±5 ppm (<100 ppm) | 0.1 ppm
CO2 (NDIR) | 0~20/100 Vol.% | ±2% FS | 0.01 Vol.%
H2S (T90≤15s) | 0~500 ppm | ±5 ppm (<100 ppm) | 0.1 ppm
NH3 (T90≤60s) | 0~100 ppm | ±5 ppm (<100 ppm) | 1 ppm
N2O (NDIR) | 0~1000 ppm | ±20 ppm | 1 ppm
CH4 (NDIR) | 0~1 Vol.% | ±100 ppm | 100 ppm
Combustion efficiency | 0.0~100.0% | (n/a) | 0.1%
Excess air coefficient | 0.00~1.99 | (n/a) | 0.01
Flue gas temperature Tgas | -20~650 ℃ | ±1.0% | 0.1 ℃
Ambient temperature Tair | -5~50 ℃ | ±1.0% | 0.1 ℃
Flue pressure Pd | -300 hPa~300 hPa | ±1.0% | 0.01 hPa
Flue gas velocity Spd | 0.1~100 m/s | ±1.0% | 0.1 m/s

Sampling rod specifications
Custom probe options: ø10×300 mm (650 ℃), ø10×500 mm (1100 ℃), ø10×1000 mm (650 ℃), ø10×1500 mm (1100 ℃), ø10×2000 mm (650 ℃); high-humidity / low-sulfur probes and sintered pre-filter options available.

Technical specifications
  • Model: MS700-FG
  • Brand: Zetron
  • Handheld multi-parameter portable analyzer (up to 7 parameters)
  • Measures temperatures, velocity/flow/volume and pressure; automatic combustion calculations
  • On-site sensor replacement and standard-gas calibration supported
  • Three-stage sample treatment and optional Peltier cooling
  • Built-in Beidou positioning and timestamping for traceability
  • Remote monitoring, optional Bluetooth printer, encrypted data logging, memory card slot, Type-C port
  • Rechargeable lithium battery up to ~8 hours; chargeable during use
  • Onboard diagnostics: airtightness self-check, sampling flow monitoring
  • Operating environment: -5 ℃ to 50 ℃, 0–95% RH
  • Dimensions: 250 × 102 × 52.5 mm

Catalogs

No catalogs are available for this product.

See all of Beijing Zetron Technology Co., Ltd.‘s catalogs

Other Beijing Zetron Technology Co., Ltd. products

Gas Analyzers

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.