Product overviewThe MIC600S-CO2 Carbon Dioxide Analyzer is designed for precise industrial monitoring of CO2 concentration. It uses a micro-flow thermal conductivity sensor and supports configurable display and sampling systems to adapt to complex operating conditions and provide accurate data for process control and safety.
Detection gasFeatures- Micro-flow thermal conductivity sensor with long service life, high sensitivity, fast response and good stability.
- Chinese human-machine dialog menu for intuitive operation.
- Timed automatic data storage enabling review of stored records at any time.
- Upper and lower limit alarm outputs adjustable across the full range; alarm point configurable within the alarm range.
- Standard RS232 or RS485 communication ports for bidirectional computer communication.
- Optional built-in pump and external filter.
- Multiple display options: B type (economic) 128×64 dot-matrix LCD; C type (engineering) 320×240 dot-matrix LCD; D type (intelligent) 800×400 touch screen with embedded RAM technology.
Specifications- Model: MIC600S-CO2
- Detection range: 0.00 ~ 99.99% CO2 (intermediate ranges optional)
- Accuracy: ≤ ±2% F.S.
- Resolution: 0.01%
- Zero drift (stability): ≤ ±2% F.S / 7d
- Range drift: ≤ ±2% F.S / 7d
- Repeatability: ≤ ±1%
- Warm-up time: ≤ 15 minutes
- Response time: T90 ≤ 15 seconds
- Sample gas flow: 300 ± 10 mL/min
- Sample gas pressure: 0.05 MPa ≤ inlet pressure ≤ 0.25 MPa
- Output signal: 4–20 mA or 0–10 mA
- Contact capacity: 220 VAC, 1 A; 24 VDC, 2 A
- Operating temperature: -10 ℃ to +45 ℃
- Humidity: ≤ 90% RH
- Power supply: 220 VAC ±10%, 50 Hz ±5%
- Overall dimensions (B type): 270 mm (W) × 132 mm (H)
- Installation size (B): 238 mm (W) × 132 mm (H) × 330 mm (D)
- Weight (B): approx. 3 kg