Residual current monitoring module LINETRAXX® RCMA423
for machinesfor medical applicationsfor the wood industry

Residual current monitoring module - LINETRAXX® RCMA423 - BENDER GmbH & Co KG - for machines / for medical applications / for the wood industry
Residual current monitoring module - LINETRAXX® RCMA423 - BENDER GmbH & Co KG - for machines / for medical applications / for the wood industry
Residual current monitoring module - LINETRAXX® RCMA423 - BENDER GmbH & Co KG - for machines / for medical applications / for the wood industry - image - 2
Add to favorites
Compare this product

Characteristics

Type
residual current
Applications
for machines
Domain
for medical applications, for the printing industry, for the wood industry

Description

AC/DC sensitive measured value acquisition type B Adjustable response values For protection of persons, fire protection, plant protection The AC/DC sensitive residual current monitor RCMA423 is designed for monitoring earthed power supply systems (TN and TT systems) where smooth DC fault currents or residual currents continuously greater than zero may occur. These are in particular loads containing six-pulse rectifiers or one way rectifiers with smoothing, such as converters, battery chargers, cons­truction site equipment with frequency-controlled drives. Currents in single conductors can also be monitored by RCMA423. The prewarning stage (50…100 % of the set response value IΔn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system. Features AC/DC sensitive residual current monitor Type B acc. to IEC 62020 and IEC/TR 60755 r.m.s. value measurement (AC+DC) Two separately adjustable response values 30 mA…3 A Frequency range 0…2000 Hz Start-up delay, response delay and delay on release Digital measured value display via LC display Measured value memory for operating value CT connection monitoring LEDs: Power On, Alarm 1, Alarm 2 Internal/external test/reset button Two separate alarm relays (one changeover contact each) N/O or N/C operation and fault memory behaviour selectable Continuous self monitoring Multi-functional LC display Password protection for device settings Sealable transparent cover Push-wire terminal (two terminals per connection) Two-module enclosure (36 mm)

Catalogs

Other BENDER GmbH & Co KG products

Residual current monitoring

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.