Energy meter power meter LINETRAXX® PEM353
frequency meterwith power quality and harmonic analyzerreactive power

Energy meter power meter - LINETRAXX® PEM353 - BENDER - frequency meter / with power quality and harmonic analyzer / reactive power
Energy meter power meter - LINETRAXX® PEM353 - BENDER - frequency meter / with power quality and harmonic analyzer / reactive power
Add to favorites
Compare this product

Characteristics

Associated function
energy meter, frequency meter, with power quality and harmonic analyzer
Measured power
reactive power, active power, apparent power
Other characteristics
three-phase, panel-mount, digital

Description

Product overview
The LINETRAXX® PEM353 is a digital universal measuring device for recording and displaying electrical quantities of supply networks and providing them via a communication interface. It measures voltages, currents, power and energy and evaluates voltage quality (THD and individual harmonics up to the 31st order). Suitable for 2-, 3- and 4‑wire systems and TN, TT and IT topologies. Standard front-panel dimensions: 96 x 96 mm.

Main features / functions
  • Comprehensive measured quantities: voltages, currents, power, energy, harmonics, unbalance, angles, THD/TDD, k‑factor, crest factor
  • Power Quality Monitoring and limit value monitoring (setpoints) with alarm forwarding
  • Energy and power measurement with storage, Time of Use (up to 8 tariffs)
  • Configurable start page showing 4 measured quantities
  • N conductor measurement and monitoring (PEM353‑N)

Measurement details
  • Phase voltages UL1, UL2, UL3 and sum (V)
  • Line‑to‑line voltages UL1L2, UL2L3, UL3L1 and sum (V)
  • Phase currents I1, I2, I3 and sum (A); neutral current In (calculated) and I4 measured on PEM353‑N
  • Residual current Ir (calculated, PEM353‑N)
  • Frequency f (Hz)
  • Per‑phase and total power: P (kW), Q (kvar), S (kVA)
  • Displacement factor cos(φ), power factor λ, phase angles (°)
  • Voltage/current unbalance (%)
  • Harmonics and distortion: THD/TOHD/TEHD for U and I; individual harmonics to 31st order; TDD for I
  • k‑factor and crest factor for currents

Energy meters
  • Active energy accuracy class acc. IEC 62053‑22: 0.5 S
  • LED pulse output for active or reactive energy
  • 2 pulse outputs (PEM353‑P)
  • Total and per‑phase energy: import/export, net and total for active/reactive and apparent energy
  • Up to 4 additional pulse counters (e.g. gas, water)

Times of Use / Tariffs
  • Up to 8 tariffs with tariff switching via digital inputs or schedule (2 schedules)
  • Energy metering per tariff and peak demand per tariff

Logs and recording
  • Energy meter log — 12 monthly values (total and per tariff)
  • Load data: configurable sliding averages, demand forecasts, peak demand log with timestamp
  • Max./min. log for 45 quantities with timestamp
  • Event log (SOE) — 100 entries with 1 ms resolution
  • PEM353‑N: daily (60 days) and monthly (36 months) logs; up to 5 data recorders with up to 16 channels each

Limit value monitoring / Alarms
  • 9 parameterisable monitoring points (setpoints)
  • Choose from 25 measured quantities for setpoints
  • Alerting via display and/or digital outputs; adjustable hysteresis

Operation & usability
  • Large backlit graphic display; configurable standard page with 4 values
  • Display password protection and operating hours counter
  • Connection fault detection (frequency, voltage/current failure, CT polarity, rotating field)

Communication and protocols
  • Galvanically isolated RS‑485 interface (1,200–38,400 bit/s)
  • LED for communication activity
  • Supported protocols: Modbus RTU, BACnet MS/TP, DNP

Applications
  • Front‑panel instrument for electrical quantity indication and replacement of analogue indicators
  • Power quality monitoring and energy data collection for energy management systems
  • Limit value monitoring with alarm forwarding; N conductor monitoring where required

Variants
  • PEM353 | 3(N)AC 230/400 V | I1/I2/I3 = 5 A | I4 = - | 2 relay outputs | Art. No. B93100355
  • PEM353‑P | 3(N)AC 230/400 V | I1/I2/I3 = 5 A | I4 = - | 2 solid‑state pulse outputs | Art. No. B93100354
  • PEM353‑N | 3(N)AC 230/400 V | I1/I2/I3 = 5 A | I4 = 5 A | 2 relay outputs | Art. No. B93100353

Optional accessories (selection)
  • Window‑type current transformers (CTB31, CTB41) — various primary currents (60 A … 1000 A), secondary 5 A or 1 A, multiple accuracy classes
  • Split‑core current transformers (KBR18, KBR32) — various ratios and accuracies

Technical specifications
  • Model name: LINETRAXX® PEM353; dimensions 96 x 96 mm (front panel)
  • Supported topologies: 2/3/4‑wire, TN/TT/IT; nominal system voltage 3(N)AC 230/400 V
  • Standard current inputs: 5 A (I1–I3); additional I4 = 5 A on PEM353‑N
  • Energy accuracy: IEC 62053‑22 class 0.5 S; logging and recorder functions as above
  • Interfaces: galvanically isolated RS‑485; Modbus RTU, BACnet MS/TP, DNP

Catalogs

No catalogs are available for this product.

See all of BENDER‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

SPS 2026
SPS 2026

24-26 Nov 2026 Nuremberg (Germany) Hall 4A - Stand 211

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
    About DirectIndustry
    DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.