- Detection - Measurement >
- Electrical Measurements >
- DIN rail current transducer
DIN rail current transducers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

• TRMS AC Current Transducer 1 Input / 1 Output • TRMS AC Current Transducer duplicator 1 input / 2 outputs • TRMS AC ...
FRER

MCOAS3 3Phase AC Current Transducer - 3 inputs / 3 outputs 3 inputs / 3 outputs
FRER

TRMS AC Current Transducer, class 0,2 1 Input - 1 Output TRMS AC Current Transducer duplicator class 0,2 1 Input - 2 Outputs TRMS ...
FRER

Primary current: 5 A - 40 A
... unstable loads, etc.). Description: - AC Current Transducer to DC current (4..20 mA - loop-powered) Input: - 8 selectable scales via DIP-SWITCH ...
SENECA | AUTOMATION INTERFACES

Primary current: 5 A - 40 A
... ease of use, and compact dimensions, the T201DC fits every kind of current measurement to 40 Adc. Description: - DC Current Transducer to DC current ...
SENECA | AUTOMATION INTERFACES

Primary current: 0 A - 100 A
... passive, contact-less loop-powered direct current transducer. The T201DC100 has functions and looks very similar to a standard current transformer, but it has stress features of measuring ...
SENECA | AUTOMATION INTERFACES

Primary current: 0 A - 10 A
CA AC Current Transducer 0.2 Class ● 1P2W / 3P3W ● TRMS option ● Precision measurement even for distorted waveform ● Self powered or Loop powered models available ● Output signal ...

Primary current: 0 A - 300 A
2A Transducer Current Transducer FEATURES: ● Direct 300A max measured for AC or DC ● 1P2W / 3P3W / 3P4W ● Output signal 4~20mA, 0~10V ● 4~20mA ...

Primary current: 30 A - 300 A
... in DC/AC current including current bipolar and DC pulse conversion for monitoring and control. SPECIFICATIONS: ● Split core CT with Clamp, easy installation ● Wide Range of Inputs ...

Primary current: 16 A - 2,460 A
The D series toroidal current transducers, designed to work with the DER3, DER3B DUAL and DER3B MED differential relays, detect zero-sequence/differential currents dispersed towards earth. ...
DOSSENA

Primary current: 80 A - 2,160 A
The D series toroidal current transducers, designed to work with the DER3, DER3B DUAL and DER3B MED differential relays, detect zero-sequence/differential currents dispersed towards earth. ...
DOSSENA

Primary current: 0.3 A - 300 A
... for its toroidal transducers, in doing so, the ferromagnetic core is able to guarantee broad magnetic qualities and detect even very low fault current values. Each Dossena transducer ...
DOSSENA

Primary current: 30 A - 50 A
... principle) and converted into a proportional andload-independent DC signal current (or voltage). The passive typeSCMU210s does not require auxiliary supply.Snap-on mounting for DIN- rail, ...

Primary current: 60 A - 600 A
... principle) and converted into a proportional and load-independent DC signal current (or voltage). The passive type SCMU210s does not require auxiliary supply. Snap-on mounting for DIN- ...

Primary current: 10 A - 600 A
... proportional and load independent DC signal current (or voltage). The active SCMU/I connects to a auxiliary supply of 230 VAC or 24 VDC. These information have to indicated on the order. Snap-on mounting ...

... up to 250 V AC, scale of 1 or 3 V RMS, and operating temperature from -10°C to +50°C. It is used in applications involving power monitoring and control systems.

... • 1 A RMS full scale output for instantaneous value • Compact DIN rail enclosure • 85 ... 265 VAC power supply RPS51 is a multiscale Rogowski coil integrator, in a compact DIN ...

... RMS DC outputs One DC output for channels sum 0...20 mA, 4...20 mA or 0...10 VDC output Response time selectable by jumpers Suitable for three-phase systems 3000 A standard full scale value Customizable ...

Primary current: 1, 5, 10 A
An extensive range of transducers providing measurement, isolation and conversion of electrical parameters into industry standard DC output signals. The range offers protection against high voltage ...

Primary current: 5, 1 A
... Measured quantity: Active power Reactive power Apparent power Power factor Phase angle Power demand Frequency Output possible with all standard signals 0...5/10/20mA • 4...20mA 0...10V ...
IME Spa

Primary current: 75, 50, 25, 100 A
1-ph Current UNIVERSAL Transducer for AC and DC up to 100A. Integrated HALL Sensor for contactless measuring. Current Range selector dial allows settings ...
TELE Haase Steuergeraete GmbH

... MAX and MIN voltage, MAX current and power, active energy for each phase. Built-in RS485 serial port (Modbus protocol). DIN rail mount type, size 4 DIN ...

Primary current: 10 mA - 5,000 mA
... Current Sensor Digital Output can measure single-phase AC voltage, current, frequency, active power, reactive power, apparent power, power factor, active energy, reactive energy, and ...

Primary current: 100, 200, 400 mA
The NIC (Non-Intrusive Current Monitor) is used as part of the preventative maintenance systems on wayside applications. The DIN rail mounted NIC units are designed ...

Primary current: 0 A - 1 A
BA50L-AI/I Leakage Current Transducer Measurement - Input: 0-1A leakage current - Output: DC 4-20mA or DC 0-5V - Measurement of leakage current - ...
ACREL CO., LTD.

Primary current: 0 A - 300 A
This device is a self-powered split core 1-element AC current isolation transducer. The electromagnetic isolation principle is applied to measure the circuit signals. ...
SHENZHEN SENSOR ELECTRONIC TECHNOLOGY Co., LTD.

Primary current: 15 mA
Summary VMS808/VMS811 eddy current transducer is to measure the dynamic and static displacement of objects equaling to structures for installation. It adopts contact measurement, and the parts include ...

Primary current: 0 A - 10 A
... is special for 3-phase AC power current A,B,C Phase measurement. It is an industrial class, high reliability, low-power consumption, high stability and high precision analog transducer. The ...
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining