Zirconia trace oxygen O2 sensor 02-661
percent levelppm levelwith electronic control

Zirconia trace oxygen O2 sensor - 02-661 - BERG Kompressoren GmbH - percent level / ppm level / with electronic control
Zirconia trace oxygen O2 sensor - 02-661 - BERG Kompressoren GmbH - percent level / ppm level / with electronic control
Add to favorites
Compare this product

Characteristics

Technology
zirconia
Output
percent level, ppm level
Other characteristics
with electronic control, long-life, miniature, in-line
Measuring range (%)

Min.: 0 %

Max.: 0.1 %

Description

Product information
02-661 NTron Oxygen sensor SenzTx-100 (0–1000 ppm) O2. Compact oxygen sensor/transmitter designed for low-level O2 monitoring. Minimum output ranges from 0–10 ppm are suitable for nitrogen generation and glovebox monitoring. The SenzTx transmitter is available in measuring ranges up to 0–96% O2 for oxygen concentrators and offers multiple process connection and output options for flexible integration.

Sensor construction
The main sensor body is manufactured from high-density PVDF and the front support ring is stainless steel. This construction delivers chemical resistance for most sampling atmospheres and compatibility with trace solvents and hydrocarbons in the sample gas; note that some zirconia sensors require high-temperature operation for certain ranges.

Installation flexibility
The compact SenzTx oxygen transmitter includes an integrated microprocessor and is designed for OEM installations with minimal user input. An optional flow-through sensor with orifice is available; with this option the sensor can accept up to 0.5 bar g and ensure correct flow through the sensing element, often eliminating the need for external flow control.

Recommendations to achieve better results and longer life
  • Regular calibration: Calibrate the SenzTx on delivery or per site procedure to ensure accurate oxygen monitoring in N2 applications.
  • Monitoring and maintenance: Continuously monitor O2 levels in the nitrogen output; inspect for irregularities and replace the sensor as required (typical zirconia cell life 3–5 years).
  • Adjust N2 sample pressure and flow correctly: For accurate N2 purity measurement set sample pressure to a maximum of 0.3 bar with minimal flow from the product tank.
  • Training and documentation: Train operators and maintenance staff on correct use, calibration and best practices for gas sampling and sensor care.

Technical specifications
  • Product number: 02-661
  • Model: SenzTx-100
  • Brand: NTron
  • Weight: 1 kg
  • Measurement technology: Zirconia (ZR)
  • Measurement range: 0 to 1000 ppm
  • Output resolution (for %): 0.01%
  • Output resolution (for ppm): 1 ppm
  • Accuracy: +/-2% of reading (or 2 ppm O2) @ calibrated temperature and pressure
  • Response time (T90): <10 seconds @ 25°C (within selected range)
  • LDL (Sensitivity): 0.01% (when measuring %) / 1 ppm (when measuring ppm)
  • Temperature range: -20°C to +50°C
  • Pressure range: 900 to 1100 mBar abs
  • Linearity: +/- 2% of reading
  • Life expectation: 3-5 years
  • Humidity: 0-95% RH non-condensing
  • Shelf life: No shelf life specified