Zirconia oxygen sensor 02-663
electrochemicaldigitalanalog

Zirconia oxygen sensor - 02-663 - BERG Kompressoren GmbH - electrochemical / digital / analog
Zirconia oxygen sensor - 02-663 - BERG Kompressoren GmbH - electrochemical / digital / analog
Add to favorites
Compare this product

Characteristics

Technology
zirconia, electrochemical
Output
digital, analog, RS-485, Modbus, 4-20 mA
Other characteristics
real-time, digital, with electronic control
Measuring range (%)

Min.: 0 %

Max.: 96 %

Description

Product information
The 02-663 NTron Oxygen sensor (SenzTx-102) is a compact O2 transmitter combining sensor and electronics. Available with zirconia or electrochemical sensing elements, it measures oxygen from low ppm up to percent levels for industrial gas and process applications. Outputs: 4–20 mA and Modbus RTU (RS-485). Power: 24 VDC. Electrical connection: M12. Process connections: KF40 flange or flow-through base.

Applications
  • Gas generation (oxygen / nitrogen)
  • Additive manufacturing
  • Glovebox purge and leak detection
  • Compressed air and industrial gas quality monitoring


Features
  • Sensor options: zirconia (ZR) or electrochemical
  • Measurement ranges: selectable from ppm to 0–96% O2 (model dependent)
  • Analogue output: 4–20 mA; Digital: Modbus RTU (RS-485)
  • Power supply: 24 VDC; Electrical connector: M12
  • Process connections: KF40 flange or flow base
  • Integrated sensor and electronics for simplified installation
  • Fast response down to low ppm concentrations


Use in monitoring systems
Senz-TX sensors integrate with PSA oxygen/nitrogen generators and compressed air monitoring systems to provide continuous oxygen concentration data. They help detect concentration deviations, identify leaks or contamination, and support process control with real-time measurement and diagnostic outputs.

Technical specifications
  • Measurement technology: Zirconia (ZR) or electrochemical
  • Measurement range: selectable from ppm to 0–96% O2 (SenzTx-102 example)
  • Resolution: 0.01% (for %) / 1 ppm (for ppm)
  • Accuracy: ±2% of reading or 2 ppm O2 (calibrated conditions)
  • Response time (T90): <10 s at 25°C (within selected range)
  • Lower detection limit (LDL): 0.01% (for %) / 1 ppm (for ppm)
  • Operating temperature: -20°C to +50°C
  • Operating pressure: 900–1100 mBar abs
  • Linearity: ±2% of reading
  • Expected life: 3–5 years
  • Humidity: 0–95% RH non-condensing

Catalogs

No catalogs are available for this product.

See all of BERG Kompressoren GmbH‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.