Paddle flow meter 8020
for liquidsDN40 - 1"1/2DN50 - 2"

paddle flow meter
paddle flow meter
paddle flow meter
paddle flow meter
Add to favorites
Compare this product
 

Characteristics

Technology
paddle
Fluid
for liquids
Pipe diameter
DN40 - 1"1/2, DN50 - 2", DN25 - 1", DN100 - 4", DN250 - 10", DN1200 - 48", DN80 - 3", DN20 - 3/4", DN225 - 9", DN32 - 1"1/4, DN275 - 11", DN65 - 2"1/2, DN125 - 5", DN60 - 2"1/4, DN300 - 12", DN175 - 7", DN90 - 3"1/2, DN200 - 8", DN150 - 6"
Installation
insertion
Material
stainless steel, brass
Supply voltage
12 Vdc, 36 VDC
Protection level
IP65
Other characteristics
remote
Volumetric flow rate

Min.: 0.5 l/min
(0.1 us gal/min)

Max.: 75,000 l/min
(19,812.9 us gal/min)

Process temperature

Min.: -15 °C
(5 °F)

Max.: 100 °C
(212 °F)

Process pressure

Min.: 0 bar
(0 psi)

Max.: 10 bar
(145.04 psi)

Repeatibility

0.4 %

Description

The paddle wheel flowmeter for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid free liquids. The Bürkert designed fitting system ensures simple installation of the devices into all pipes from DN 20…DN 400. The flowmeter produces a frequency pulse signal, proportional to the flow rate, which can easily be transmitted and processed by a Bürkert transmitter/controller. Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC’s (both PNP and NPN) Connection to Bürkert devices in remote versions

Exhibitions

Meet this supplier at the following exhibition(s):

ACHEMA 2024
ACHEMA 2024

10-14 Jun 2024 Frankfurt am Main (Germany) Hall 8.0 - Stand J80

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.