Product OverviewGasboard-3520 is an online natural gas calorific value analyzer that delivers continuous, metering-grade measurement of gas composition and energy parameters. It integrates NDIR, TDLAS, TCD and ultrasonic sensing to provide real-time outputs of gross/net calorific value, Wobbe index, density and key component concentrations. The unit is explosion-proof (Ex) and complies with OIML R140 Class A for fiscal custody transfer applications. Multiple communications (RS232/RS485, 4-20 mA, TCP/IP) and automatic calibration support long-term, low-maintenance operation.
Application- Natural gas production and processing: real-time composition and calorific monitoring for quality control.
- Fiscal gas metering and trade settlement: metering-grade measurements compliant with OIML R140 Class A.
- Pipeline transmission and distribution: gas quality monitoring and hydrogen blending management in networks.
- Gas turbine and power generation: real-time calorific data for combustion optimization and emissions control.
- Biomethane and renewable gas: composition and energy value verification for injection and utilization.
Features- Integrated multi-technology sensing: NDIR, TDLAS, TCD and ultrasonic methods for continuous, fast and stable analysis compared with conventional GC.
- Comprehensive energy outputs: gross/net calorific value, higher/lower Wobbe index, standard and relative density, plus CO2, H2, CH4 and C2+ concentrations.
- Hydrogen-blended gas compatibility: accurate simultaneous measurement of hydrogen and hydrocarbons without carrier gas.
- Meteorological and fiscal compliance: OIML R140 Class A capability for custody transfer.
- Low maintenance design: no combustion, no carrier gas or consumables required.
Specifications- Gross Calorific Value (HsV): 33.966 ~ 46.954 MJ/m³ — output: yes
- Net Calorific Value (HiV): 31.467 ~ 42.458 MJ/m³ — output: yes
- Higher Wobbe Index (Ws): 43.956 ~ 53.946 MJ/m³ — output: yes
- Lower Wobbe Index (Wi): 41.3 ~ 51.6 MJ/m³ (composition-dependent) — output: yes
- Standard Density (Rho): 0.66 ~ 1.04 kg/m³ — output: yes
- Relative Density (d): 0.5 ~ 0.8 — output: yes
- CO2: 0 ~ 5 %vol — output: yes
- H2: 0 ~ 10 %vol — output: yes
Performance & Operational Data- Measurement uncertainty: HsV/HiV/Ws/Wi/d ≤ 0.5%; CO2/H2 ≤ 1.0% : MPE ≤ ±0.1; CO2/H2 > 1.0% : MPE ≤ ±10%
- Repeatability: HsV/HiV/Ws/Wi/d ≤ 0.1%; CO2/H2 ≤ 1.0% : Repeatability ≤ ±0.02
- Update rate: 1 Hz; Response time (T90) ≤ 6 s
- Inlet gas pressure: 2 ~ 50 kPa; Optimal flow rate: 0.7 ~ 1.2 L/min
- Power supply: AC 220V ±10%, 50Hz ±1Hz
- Operating temperature: -10℃ ~ +50℃; Storage: -25℃ ~ +70℃; Relative humidity: 5 ~ 85% RH (non-condensing)
- Environmental protection: IP65; Electromagnetic/Mechanical grade: E2 / M1
Interfaces & Approvals- Analog outputs: 4 ~ 20 mA
- Digital interfaces: RS232 or RS485; TCP/IP supported
- Metrological approval: OIML R140 Class A
- Explosion protection: Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db
Technical specifications- Model: Gasboard-3520
- Measurement outputs: gross/net calorific value, higher/lower Wobbe index, standard and relative density, CO2, H2, C1, C2+ and other hydrocarbons
- Calorific value ranges: HsV 33.966–46.954 MJ/m³; HiV 31.467–42.458 MJ/m³
- Wobbe index ranges: Ws 43.956–53.946 MJ/m³; Wi 41.3–51.6 MJ/m³ (composition-dependent)
- Gas component ranges: CO2 0–5 %vol; H2 0–10 %vol; CH4 60–100 %vol; C2+ 0–15 %vol
- Accuracy / MPE and repeatability as stated above
- Update rate: 1 Hz; Response time (T90) ≤ 6 s
- Protection & approvals: IP65, E2/M1, OIML R140 Class A, Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db
- Communication: 4–20 mA analog outputs; RS232/RS485; TCP/IP