Rooftop air conditioner Rebel Applied
energy-savingreversibleoutdoor

Rooftop air conditioner - Rebel Applied - Daikin Applied - energy-saving / reversible / outdoor
Rooftop air conditioner - Rebel Applied - Daikin Applied - energy-saving / reversible / outdoor
Rooftop air conditioner - Rebel Applied - Daikin Applied - energy-saving / reversible / outdoor - image - 2
Rooftop air conditioner - Rebel Applied - Daikin Applied - energy-saving / reversible / outdoor - image - 3
Rooftop air conditioner - Rebel Applied - Daikin Applied - energy-saving / reversible / outdoor - image - 4
Add to favorites
Compare this product

Characteristics

Configuration
rooftop
Other characteristics
energy-saving, reversible, outdoor
Cooling power

Max.: 562.7 kW
(765.05 hp)

Min.: 70.34 kW
(95.63 hp)

Description

Product overview
Rebel Applied is a packaged rooftop HVAC unit designed for new construction and retrofit applications. The platform is offered in refrigeration-only and heat-pump variants and features low‑GWP R‑32 refrigerant, modular cabinet construction and multiple heating and control options. Models referenced: DPSA, DFSA, DHSA.

Key capabilities
Rebel Applied delivers a thermally-broken, double-wall cabinet with very low air leakage and modular lengths to simplify installation and retrofits. The platform supports inverter scroll (modulating) compressors for precise load matching and improved part-load heating capacity; non-inverter compressor options are available for specific low-ambient requirements. Optional gas phase air cleaning (sorbent media) reduces CO2, VOCs and contaminants and — when used with an IAQ procedure — can lower outdoor air requirements and HVAC energy use.

Performance highlights
  • Heating and cooling operation (refrigeration-only and heat-pump variants)
  • Capacity range: 20 to 160 tons
  • Airflow range: 5,000 to 45,000 CFM
  • Refrigerant: low‑GWP R‑32
  • IEER: up to 20.0 (inverter/modulating designs referenced up to ~20.3 IEER in context)

Features
  • Low‑GWP R‑32 refrigerant
  • Modular cabinet design in 4" increments for retrofit flexibility
  • Thermally-broken, double-wall foam cabinet construction (R‑13 insulation)
  • Class 6 leakage rating at ±6" static pressure and <0.5% leakage up to 5" static pressure
  • Available inverter scroll compressors for modulating operation and high part-load efficiency
  • Available non-inverter compressor options for low-ambient needs
  • Optional gas phase sorbent media for CO2, VOC and contaminant removal
  • Configurable accessories: final filters, sound attenuators, humidifiers, blank/access sections
  • MicroTech 4 unit controller with airflow measurement, power monitoring and building communications
  • Real-time refrigerant system monitoring for diagnosis and maintenance
  • Up to 37% shorter and 30% lighter than legacy applied rooftop units

Heating options
Multiple heating sources supported: electric heat, propane, natural gas, steam or hot water, to match project requirements.

Retrofit & configurability
The modular, no-transition curb and configurable cabinet reduce installation complexity for retrofit projects, enabling direct replacement of legacy units with reduced footprint and weight and tailored configurations to meet site constraints.

Gas phase air cleaning technology
Gas phase sorbent media targets CO2, VOCs and other gaseous contaminants while allowing oxygen and water vapor passage. Applied with an IAQ procedure, the technology can reduce required outdoor air volume and the total cooling load, simplifying retrofits and improving indoor air quality.

Controls & monitoring
MicroTech 4 unit controller measures airflow, monitors power and interfaces with building communications. Documentation supports controls integration. Real-time refrigerant monitoring is available to facilitate diagnosis and maintenance.

Technical specifications
  • Product name / series: Rebel Applied
  • Models referenced: DPSA / DFSA / DHSA
  • Capacity range: 20 to 160 tons
  • Airflow range: 5,000 to 45,000 CFM
  • Refrigerant: low‑GWP R‑32
  • IEER: up to 20.0 (inverter/modulating contexts referenced up to ~20.3 IEER)
  • Cabinet insulation: R‑13, double-wall foam with thermal break
  • Cabinet leakage: Class 6 at ±6" static pressure; <0.5% leakage up to 5" static pressure
  • Modularity: 4" increments for retrofit flexibility
  • Size/weight improvements vs legacy: up to 37% shorter and 30% lighter
  • Compressor options: inverter scroll (modulating) and non-inverter staged compressors
  • Heating options: electric, propane, gas, steam, hot water
  • Controls: MicroTech 4 (airflow measurement, power monitoring, building communications)
  • Filtration: gas phase sorbent media for CO2/VOC removal (IAQ Procedure compatibility)
  • Additional: configurable final filters, sound attenuators, humidifiers, blank/access sections; real-time refrigerant monitoring
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.