Characteristics

Display
with LED display
Units of measurement
°C
Communication
4-20 mA, analog output, IO-Link
Protection level
IP65
Configuration
screw-in
Applications
for flue gas
Other characteristics
stainless steel, programmable, dual-channel, 2 channel
Temperature

Max.: 2,000 °C
(3,632 °F)

Min.: 400 °C
(752 °F)

Precision

1 %

Resolution

0.1 °C
(32.18 °F)

Response time

60 ms

Description

Product description:
The CellaCombustion PK 75 performs temperature measurement at a specific CO2-sensitive wavelength where hot carbonaceous flue gases exhibit high optical density and reliable radiative properties. Designed for flue-gas temperature monitoring in gas-fired boilers and small combustion systems, the PK 75 belongs to the CellaTemp® PK series and features the Vitality indicator — a SMART self-monitoring, analysis and reporting function that continuously records operating data and supports preventive maintenance by signalling recommended service and calibration times based on operating conditions.

Special features:
  • Measuring range: 400–2000 °C (model-dependent)
  • Compact stainless-steel housing Ø30×210 mm
  • Universally configurable switching outputs
  • High optical resolution with precision lenses
  • IO-Link interface (V1.1.3)
  • On-sensor pushbuttons or remote parameter setting via plant interface
  • 2 × PNP open-collector switching outputs
  • Simple mounting using M30 central thread
  • Large, high-visibility 4-digit LED display


Technical data — Measurement parameters:
Measuring range: 400–2000 °C
Sensor: Thermopile
Spectral range: CO2 band (wavelength optimized for carbonaceous gases)
Response time (t90): ≤ 60 ms
Measurement uncertainty: 1 % of reading
Repeatability: 4 K
Temperature coefficient: 0.04 %/K
Resolution (current output): 0.1 K + 0.005 % of span
Resolution (interface): 0.1 K
Resolution (display): 1 K

Electrical parameters:
Analog output: 0(4)–20 mA linear, switchable, scalable
Load (output): ≤ 500 Ω
Switching outputs: 2 × PNP open collector, 24 V DC, 150 mA max.
Test input: 10–34 V DC (per IEC 61131-2)
Interface: IO-Link V1.1.3
Power supply: 18–32 V DC
Current consumption: ≤ 50 mA at 24 V DC

Features:
Display: 4-digit red LED, digit height 8 mm
Status indicators: 3 × LED
Controls: 3 pushbuttons (local configuration)

General parameters:
Connection: M12 5-pin (A-coding)
Operating ambient: 0–65 °C
Storage temperature: -20–+80 °C
Permissible humidity: max. 95 % r.H. (non-condensing)
Housing: Stainless steel V2A (1.4305), Protection class IP65
Dimensions: Ø30 × 210 mm (without plug)
Weight: ≈ 0.4 kg

Adjustable parameters (selection):
Analog output scaling, emissivity quick-adjust, protective-glass transmission, damping time constant, max-hold time, switching contact mode/source/points/delays, temperature correction via interpolation points, Vitality indicator settings, service parameters, factory reset, key lock, display selection °C/°F, temperature simulation.

Functions:
Overtemperature alarm (internal >75 °C), test function (button or test input), service simulation, diagnostics (reverse polarity, overload, wrong supply), reverse-polarity protection for power, analogue and switching outputs.

Scope of delivery:
Infrared pyrometer CellaCombustion PK, short manual, 2 fixing nuts

Software:
SW 50 (IO-Link software)

Measuring field / Optics (example):
Version example: PK 75 BF 1
Configured measuring range: 400–2000 °C
Target size (at 0.4 m): 7 mm
Focus distance: 0.4 m
Measuring field shape: round
Measuring principle: one-colour

Technical specifications:
  • Model: CellaCombustion PK 75
  • Series: PK
  • Measuring range: 400–2000 °C
  • Target size (at 0.4 m): 7 mm
  • Sensor technology: Thermopile
  • Interface: IO-Link V1.1.3
  • Analog output: 0(4)–20 mA
  • Switching outputs: 2 × PNP open collector
  • Power supply: 18–32 V DC
  • Protection class: IP65
  • Housing: Stainless steel V2A (1.4305)
  • Dimensions: Ø30 × 210 mm (without plug)
  • Weight: ≈ 0.4 kg

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

Inter Foundry 2026
Inter Foundry 2026

10-12 Sep 2026 Coimbatore (India)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.