Functions - Locking device with guard interlocking in acc. with EN ISO 14119 (type 4)
Activation mode of safety outputs - Safety outputs active if safety door is closed and locked
Operating principle - Open circuit current principle – Actuator locked if electromagnet is activated
SIL - 3, IEC 61508
SILCL - 3, IEC/EN 62061
Performance Level (PL) - Up to and including e, EN ISO 13849-1
MTTFd - 2,968 years, EN ISO 13849-1
PFHD - 1.15E-9 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 4, EN ISO 13849-1
DC - High
Encoding level - Low, EN ISO 14119
Type of wiring - Series connection
Single connection
External safeguarding for supply circuit - 2A type Gg (or equivalent)
Supply voltage UB - 24 V, DC, -10 ... 10 %
Current consumption, max. - 1,200 mA
Number of safety-related switching inputs - 2 Piece(s)
Number of digital switching inputs - 1 Piece(s)
Type - Digital switching input
Switching voltage, type. - 24 V
Voltage type - DC
Current consumption, type. - 5 mA
Teach input for actuator - No
Function - I4 activation input: electromagnet
Type - Safety switching input
Voltage type - DC
Switching voltage, type. - 24 V
Current consumption, type. - 5 mA