Application - Muting interface for muting applications in combination with standard variants of the MLC and ELC safety light curtains, as well as MLD multiple light beam safety devices
Functions - Muting-timeout extension
Muting enable function
Sequence controlled 2-sensor muting
Sequence controlled 4-sensor muting
Timing controlled 2-sensor muting
Restart - Automatic
Manual
SIL - 3, IEC 61508
SILCL - 3, IEC/EN 62061
Performance Level (PL) - e, EN ISO 13849-1
PFHD - 2.5E-09 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 4, EN ISO 13849-1
Protective circuit - Overvoltage protection
Polarity reversal protection
Short circuit protected
Supply voltage UB - 24 V, DC, -20 ... 20 %, Compensation necessary at 20 ms voltage dip, min. 250 mA (+ external loads)
Current consumption, max. - 150 mA, Without external load
Power consumption, max. - 3.6 W, For 24 V, plus output load
Residual ripple - -5 ... 5 %, From UB
Number of safety-related switching inputs - 2 Piece(s)
Number of digital switching inputs - 8 Piece(s)
Type - Digital switching input
Switching voltage high, min. - 27 V
Switching voltage low, max. - 2.5 V
Switching voltage, type. - 24 V
Voltage type - DC
Function - Control input, reset of the control
Control input for Reset
Function - Control input, muting sensor 1 of the control
Function - Control input, muting enable/muting timeout
Function - Control input for Reset