- Robotics - Automation - Industrial IT >
- Automation >
- Emergency stop safety relay
Emergency stop safety relays
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Trigger voltage: 24 V
... Monitors a wide variety of safety and non- safety input devices:Optical-based safeguarding devices, such as Safety Laser ScannersPositive-opening safety switches used for guard interlockingEmergency- stop ...
Trigger voltage: 24 V
... Increases the switching current capacity of low voltage primary safety devices to 6 amps Serves as a relay for primary safety devices with OSSD solid-state or hard contact outputs and external ...
... Application options PNOZsigma safety relays PNOZsigma safety relays for E- STOP, safety gates, light barriers When monitoring E- STOP, ...
PILZ
... Our PNOZ X safety relays are proven through their reliability and sturdiness. They are used in a wide range of applications and in the most diverse safety applications. Use one PNOZ X per safety ...
PILZ
... Applications: Suitable for basic functions Safety relay PNOZ c1 – Monitor an E- STOP or safety gate – in any application – safe, simple, yellow. Use one safety relay ...
PILZ
Tripping current: 6 A
Trigger voltage: 24, 250 V
... Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors ...
SCHMERSAL
Tripping current: 6 A
Trigger voltage: 24, 230 V
... Suitable for the signal processing of outputs with contact sensors 3 safety contacts, STOP 0 1 Signalling output ...
SCHMERSAL
Tripping current: 6 A
Trigger voltage: 24, 250 V
... Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety ...
SCHMERSAL
... output load Number of safety-related switching outputs (OSSDs) - 2 Piece(s) Type - Safety-related switching output OSSD Voltage type - AC/DC Switching element - Relay, NO Switching element - ...
Leuze electronic GmbH + Co. KG
... Our Bulletin 700-HPS PCB Pin Style Safety Control Relays feature mechanically linked contacts that are required for safety circuits as per EN 50205 (Type B). Meets EN 50205 (Type B) requirements Provides ...
Trigger voltage: 24 V - 240 V
... SIRIUS 3SK safety relays offer outstanding simplicity, flexibility and cost-effectiveness. Their modular design simplifies the planning, commissioning and expansion of plants. Simple safety functions, ...
Siemens Safety Integrated
... guarantees versatile safety at the highest level. • 3 instantaneous safety contacts • 1 instantaneous signaling contact • Connection of: • Emergency stop button • Mechanical safety ...
... The emergency stop module UF 6925 is suitable to protect men and machine by safety related enabling or disabling of a safety circuit. It is used in applications with e- stop ...
DOLD
... of the safety functions lead to a sustainable reduction in storage costs. Besides safety functions such as emergency stop, protective door, non-equivalent safety ...
DOLD
... latching rotary switches. Besides safety functions such as emergency stop, protective door, non-equivalent safety sensor, two-hand or light barrier, it also allows you ...
DOLD
Tripping current: 20 mA
Trigger voltage: 24 V
... ISO 13851. In this way, a high level of protection against tampering is provided. • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting ...
Tripping current: 20 mA
Trigger voltage: 24 V
... start with automatic start or a start button • Monitoring of downstream relays or contactors. • Simultaneity monitoring to monitor safety components over time • Relay start using a monitored start ...
Tripping current: 8 A
Trigger voltage: 250 V
... AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 AWAX26XXL : Safety/diagnostic contacts: 3x NO 8A/250V redundant / 1x NF 8A/250V serial (XXL version) or parallel (XXLP version) AWAX26XXLT6 ...
COMITRONIC - BTI
Tripping current: 8 A
Trigger voltage: 250 V
... switches / emergency stops Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: ...
COMITRONIC - BTI
Tripping current: 8 A
Trigger voltage: 250 V
... switches / emergency stops Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: ...
COMITRONIC - BTI
Tripping current: 4, 6 A
Trigger voltage: 24, 250 V
... It is suitable for emergency stop switch, security door lock, PNP/NPN light curtain photoelectric, 2-wire normally open contact side (carpet)/normally closed contact side (carpet) with resistance/no resistance ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 24, 240, 250 V
... Supports emergency stop switch, safety door lock, PNP type safety light curtain, and photoelectric input Precise control, can be adapted to different safety functions ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 24, 240, 250 V
... Supports emergency stop switch, safety door lock, and passive switch inputs Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, ...
Bytorent Technology Co., Ltd.
... disconnect, switch, or convert voltage - even where space is at a premium. Our product portfolio comprises a diversity of relay and optocoupler modules that use the practical terminal block format. Our analog transformers and temperature ...
MURRELEKTRONIK
... Nothing Connections - Terminal blocks Safety devices to be connected - Safety devices with feedback input for external relay monitor (EDM), such us EOS4 X , EOS2 X, Admiral AX, Vision VX/VXL/MXL and ...
REER
... The modular and configurable MODSI safety system can monitor and control various safety equipment in parallel, including safety light curtains / grids, mechanical switches, floor mats, emergency ...
... Switching status indicator In combination with the safety light curtains SG-I and safety light arrays SB-I, the relay unit allows for the interruption of safety-relevant circuits. ...
... Emergency Stop & Time Relay SAFEONE DNSR-2R2 The emergency stop relay is configured individually for your application and can be supplied with instantaneous, ...
... Used for monitoring safety light curtains (NPN, PNP output) and photoelectric two handed buttons characteristic: 1、Detectable short circuit faults in input contacts; 2、Circuit with self monitoring; 3、Real time monitoring of working ...
Shandong laien optic-electronic technology co.,ltd.
Tripping current: 40 mA
Trigger voltage: 24 V - 230 V
... generating a safety-oriented output signal (enable). Depending on the design, separating safety devices may include protective screens, safety doors, enclosures, covers, screens, etc. Basic ...
... SCR-i range of Safety Relays have been designed in accordance with EN60204-1 for safety circuits and they can be used in conjunction with mechanical interlock guard switches, emergency ...
Idem Safety Switches
Tripping current: 4, 2 A
... operation with the Mechan range of non-contact safety switches, the SRL-1 is also suitable for use with dual channel Emergency Stop buttons, or safety devices with 2 safety ...
... Stop category: 0 Performance-Level: e Safety category: 4 2 channel emergency stop circuit Contacts: 2 force guided safety contacts AC 250V/6A Operating voltage: DC24V, ...
Zander GmbH & Co. KG, Hermann
... Safety module – Suitable for control of limit switches for safety gates, safety magnetic sensors, emergency stops and electro-sensitive protection devices ...
Comepi srl
... Using RTK Linden DA149 intrinsically safe relays, control signals and other data can be exchanged between items of equipment in hazardous areas and between hazardous and safe-area equipment. The range includes four models, ...
... Safety relay module meets EN/ISO 13849-1 Cat.4 safety requirements, suitable for high-security requirements of industrial site monitoring for various signal, including emergency stop-signal, ...
... From safety relays to safety switches, the complete range of products needed for your application can be found at Bernstein. The SCR safety relays reliably evaluate ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group