Special version - Integrated muting indicator
Functions - Alternative connection for second muting signal
Contactor monitoring (EDM), selectable
Muting-timeout extension
Muting enable function
Start/restart interlock (RES), selectable
Integrated laser alignment aid - No
Reflective element for laser alignment aid - No
Integrated muting indicator - Yes
Integrated status indicator - Yes
Muting type - Timing controlled 4-sensor muting
Type - 4, IEC/EN 61496
SIL - 3, IEC 61508
SILCL - 3, IEC/EN 62061
Performance Level (PL) - e, EN ISO 13849-1
PFHD - 6.6E-09 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 4, EN ISO 13849
Operating range - 0.5 ... 6 m
Number of beams - 3 Piece(s)
Beam spacing - 400 mm
Type of muting sensors - PRK 25C retro-reflective photoelectric sensors
With device column - Yes
Number of muting sensors - 4 Piece(s)
Column height without foot - 1,600 mm