Flammability test chamber SBI 915
climaticgasthermal shock

Flammability test chamber - SBI 915 - NETZSCH Analyzing & Testing - climatic / gas / thermal shock
Flammability test chamber - SBI 915 - NETZSCH Analyzing & Testing - climatic / gas / thermal shock
Add to favorites
Compare this product

fo_shop_gate_exact_title

Characteristics

Type
climatic
Controlled parameter
gas
Test type
thermal shock, analysis, flammability
Application domain
for quality control
Options and accessories
with window
Other characteristics
thermal
Temperature

Max.: 1,300 °C
(2,372 °F)

Min.: -100 °C
(-148 °F)

External length

148 cm
(58.3 in)

External height

245 cm
(96.46 in)

External depth

148 cm
(58.27 in)

Description

Fire Testing System for determining the reaction of building products to fire when exposed to thermal attack by a single burning item, in accordance with EN 13823 The SBI 915 from NETZSCH TAURUS Instruments GmbH is easy to operate, offering innovative control and data acquisition options in an intuitive format with ample user guidance. The high-resolution color touch display on the “SBI Control“ cabinet allows for measuring and control with the integrated Single Board Computer, Windows operating system and SBI software. There is thus no longer any need for manual controls such as switches, controllers or buttons; the status of the testing system is clearly displayed and the systems prevents any critical operating errors. The storage, analysis and recording of all test data is handled entirely via the control unit. Well thought-out details along with the use of high-quality materials guarantee the SBI test system a long product life and a low degree of wear and tear. Method Test Setup The product specimen is mounted on the trolley rig forming a room corner. The specimen consists of two parts which form a rightangled corner. A triangular propane diffusion gas burner acts as the heat and ignition source. Floor, specimen and burner are located on a trolley that can be removed from the room for easy mounting of the specimens. Test Method The sampleis exposed to flames with a heat release of 30 kW for a period of 20 minutes. Heat and smoke production is measured within the ducting for the exhaust hood, and flame spread is observed during the test.

Exhibitions

Meet this supplier at the following exhibition(s):

K-Messe	2025
K-Messe 2025

8-15 Oct 2025 Düsseldorf (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.