Product overview- Very low noise
- Minimal depth in enclosure
- Functional design
- Time-saving installation
- Weatherproof and UV resistant
Technical dataAxial fan, ball bearing — service life min. 50,000 h at 25°C/77°F (65% RH); fan body aluminium, rotor plastic.
Connection — 2 wires with pressure clamps 2.5 mm², length 100 mm.
Casing (filter fan and exit filter) — plastic according to UL94 V-0, light grey.
Hood (filter fan and exit filter) — plastic UL94 V-0, light grey; weatherproof and UV resistant according to UL746C (f1).
Mounting frame — with double-sided industrial adhesive band for fixing to the outside of the enclosure; additional screws may be necessary in some applications; cutting template included.
Filter mat — G4 according to DIN EN 779, filtering degree 94%.
Filter material — synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; moisture resistant to 100% RH; washable/reusable.
Operating/storage temperature — -45 to +70°C (-49 to +158°F).
Protection type / Protection class — IP54 / I (earthed).
Variants (selection)01800.00-00 | 230VAC, 50Hz | air vol. free flow 21 m³/h | air vol. with filter 16 m³/h | current 80 mA | power 13 W | noise 31 dB(A) | depth 45 mm | cut-out 97 x 97 mm ±0.4 | weight 0.60 kg
01801.00-00 | 230VAC, 50Hz | 55 m³/h | 42 m³/h | 100 mA | 15 W | 40 dB(A) | 58 mm | 125 x 125 mm ±0.4 | 1.00 kg
01802.00-00 | 230VAC, 50Hz | 102 m³/h | 68 m³/h | 100 mA | 15 W | 39 dB(A) | 86 mm | 176 x 176 mm ±0.4 | 1.30 kg
01800.00-01 | 120VAC, 60Hz | 24 m³/h | 18 m³/h | 160 mA | 13 W | 31 dB(A) | 45 mm | 97 x 97 mm ±0.4 | 0.60 kg
01801.00-01 | 120VAC, 60Hz | 63 m³/h | 48 m³/h | 180 mA | 15 W | 40 dB(A) | 58 mm | 125 x 125 mm ±0.4 | 1.00 kg
01802.00-01 | 120VAC, 60Hz | 117 m³/h | 78 m³/h | 180 mA | 15 W | 39 dB(A) | 86 mm | 176 x 176 mm ±0.4 | 1.30 kg
Features / Benefits- The self-adhesive seal of the mounting frame prevents dust and water ingress into the cabinet.
- Functional intake and exit hoods effectively prevent direct intrusion of falling water and dust, reducing filter contamination and replacement frequency.
- Air channeling design reduces operational noise of the filter fan.
- Functional and modern design enables time-saving assembly and maintenance.
- All filter fan models are available with integrated airflow monitor on request.
- EMC versions and other voltages available on request.
- Air direction can be switched by reversing the axial fan (sizes 1–3).
Note* Using fine filter mats type F5 increases protection to IP55 but reduces air volume.
Technical specifications- Model: FF-018
- Fan type: axial fan with ball bearing
- Expected service life: ≥ 50,000 h at 25°C (65% RH)
- Fan body material: aluminium; rotor: plastic
- Connections: 2 wires with pressure clamps 2.5 mm², length 100 mm
- Casing and hood: plastic UL94 V-0, light grey; hood weatherproof and UV resistant (UL746C f1)
- Mounting: double-sided industrial adhesive band; cutting template included; screws may be required
- Filter class: G4 (DIN EN 779), 94% filtering degree; optional F5 increases protection to IP55
- Filter media: synthetic fibre, washable/reusable, temperature resistant to 100°C, self-extinguishing class F1
- Operating/storage temperature: -45 to +70°C
- Protection rating: IP54 (increased to IP55 with F5; reduces airflow)
- Noise levels, power consumption and dimensions vary by variant (see variants block)