The MarvelXACT UHPLC connection system is engineered for ultra-high performance liquid chromatography to minimise dead volume, simplify connections and deliver reproducible chromatography under high pressure. The system combines a zero-dead-volume tip design with a patented torque-limiting mechanism and multiple material options to suit analytical requirements.

The MarvelXACT connection system
MarvelXACT provides reliable, repeatable face sealing on 10-32 tapered ports. An integrated, patented torque-limiting mechanism prevents over- or under-tightening and gives tactile/audible feedback (a distinct "click") at the optimum torque, enabling correct installation without tools. The sealing technology minimises internal dead volume to reduce carryover, peak tailing and peak broadening. Components are available in bio-inert PEEK, PEEK-lined stainless steel, PEEKsil™ and pure stainless steel. The flexible 1/32in OD capillary facilitates routing, and the patented design adapts automatically to varying port depths. The fittings are rated for high-pressure use and for extended connection cycles.

Your advantages at a glance
  • No tools. No guesswork
    The torque-limiting mechanism ensures consistent, correct tightening by a tactile/audible click when the target torque is reached.
  • 100+ reuses guaranteed
    Fittings are designed for more than 100 reliable connection/disconnection cycles without loss of sealing performance.
  • Optimal chromatography at high pressure
    MarvelXACT assemblies withstand pressures up to 1,300 bar (19,000 psi) while minimising dead volume to preserve peak shape and resolution.
  • Material and size traceability
    Identification sleeves indicate length and inner diameter. Options include PEEK-lined stainless steel, PEEKsil™ and pure stainless steel to match analytical and bioinert requirements.

Conventional fitting vs MarvelXACT
Conventional conical fittings rely on a ferrule plus complex assembly and specialised tooling to achieve a seal, which can increase internal volume and accelerate component wear under high torque. In contrast, MarvelXACT seals at the lower end of the port without a ferrule, simplifying assembly, reducing required torque and increasing the number of reliable connection cycles. The protected tip design ensures zero dead volume (ZDV) and reduces hardware wear, extending component life and improving chromatography.

Ordering Information (Inner Diameter | Length | Volume | Stainless Steel | PEEK-Lined Stainless | PEEKsil)
Inner Diameter (μm) | Length (mm) | Volume (μl) | Stainless Steel | PEEK-Lined Stainless | PEEKsil
25 | 150 | 0.075 | - | 980-35048 | 980-35068
25 | 250 | 0.123 | - | 980-35049 | -
25 | 350 | 0.172 | - | 980-35050 | 980-35069
25 | 500 | 0.245 | - | 980-35051 | -
25 | 600 | 0.295 | - | 980-35052 | 980-35070
50 | 150 | 0.295 | - | 980-35053 | 980-35071
50 | 250 | 0.491 | - | 980-35054 | -
50 | 350 | 0.687 | - | 980-35055 | 980-35072
50 | 500 | 0.982 | - | 980-35056 | -
50 | 600 | 1.178 | - | 980-35057 | 380-35073
75 | 150 | 0.663 | - | 980-35058 | 980-35074
75 | 250 | 1.104 | - | 980-35059 | -
75 | 350 | 1.546 | - | 980-35060 | 980-35075
75 | 500 | 2.209 | - | 980-35061 | -
75 | 600 | 2.651 | - | 980-35062 | 980-35076
100 | 100 | 0.785 | 980-35032 | - | -
100 | 150 | 1.178 | 980-35033 | 980-35063 | 980-35077
100 | 250 | 1.963 | 980-35034 | 980-35064 | -
100 | 350 | 2.749 | 980-35035 | 980-35065 | 980-35078
100 | 500 | 3.927 | 980-35036 | 980-35066 | -
100 | 600 | 4.712 | 980-35037 | 980-35067 | 980-35079
125 | 150 | 1.841 | 980-35038 | - | -
125 | 250 | 3.068 | 980-35039 | - | -
125 | 350 | 4.295 | 980-35040 | - | -
125 | 500 | 6.136 | 980-35041 | - | -
125 | 600 | 7.363 | 980-35042 | - | -
254 | 150 | 7.6 | 980-35043 | - | -
254 | 250 | 12.667 | 980-35044 | - | -
254 | 350 | 17.734 | 980-35045 | - | -
254 | 500 | 25.335 | 980-35046 | - | -
254 | 600 | 30.402 | 980-35047 | - | -

Technical characteristics / specifications
  • Face sealing for 10-32 tapered ports with reproducible, repeatable sealing.
  • Integrated patented torque-limiting mechanism with tactile/audible "click" to indicate correct torque.
  • Materials: bio-inert PEEK, PEEK-lined stainless steel, PEEKsil™ and pure stainless steel options.
  • Flexible 1/32in OD capillary for routing; automatic adaptation to varying port depths.
  • Zero dead volume (ZDV) protected tip design to optimise chromatography and reduce carryover.
  • Pressure rating up to 1,300 bar (19,000 psi).
  • Designed for over 100 reliable connection/disconnection cycles.
  • Comprehensive ordering matrix with multiple inner diameters, lengths and product codes (see ordering information table above).