Oil flow monitor VEG series
for waterDN100 - 4"DN15 - 1/2"

oil flow monitor
oil flow monitor
oil flow monitor
Add to favorites
Compare this product
 

Characteristics

Fluid
for oil, for water
Pipe diameter
DN100 - 4", DN15 - 1/2", DN20 - 3/4", DN25 - 1", DN32 - 1"1/4, DN40 - 1"1/2, DN50 - 2", DN65 - 2"1/2, DN80 - 3"
Installation
threaded
Material
stainless steel
Supply voltage
230VAC, 24 Vdc, 60VDC
Protection level
IP67
Other characteristics
compact
Volumetric flow rate

Max.: 3,414 l/min
(901.9 us gal/min)

Min.: 0.1 l/min
(0 us gal/min)

Process temperature

Max.: 85 °C
(185 °F)

Min.: -20 °C
(-4 °F)

Process pressure

Max.: 200 bar
(2,900.75 psi)

Min.: 0 bar
(0 psi)

Description

No movable parts in the flow setpoint at extremely low flow possible high compressive strength applicable with different nominal diameters The calorimetric SIKA flow monitors of the VE series are used for monitoring volumetric flows. Typical applications are: • dry-run protection for pumps • monitoring of lubrication circuits • cooling and heating circuits • leakage monitoring The flow monitor is easily screwed directly into the process line by means of a connection thread. As the measuring probe is available in two different lengths, a wide range of pipelines with various nominal diameters and wall thicknesses is covered. In the compact version VES, the flow sensor and the associated evaluation electronics form one unit. In this way, the flow can be monitored directly at the measuring point. The calorimetric flow monitor works according to the principle of temperature difference detection. There are two temperature sensors inside the cylindrical measuring probe. They have optimal heat-conducting contact with the medium and at the same time a good thermal insulation to each other. One sensor is heated with constant power, the other is not heated and thus assumes the medium temperature. When the medium is stationary, there will be a constant temperature difference between the two sensors. The heated sensor is cooled by the flowing medium. The changed temperature difference between the two sensors depends on the flow velocity and is therefore a parameter for monitoring the preselected minimum flow. This signal is fed by a comparator controlling a transistor output signal.

Catalogs

No catalogs are available for this product.

See all of SIKA‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.