OverviewLIQUANTY liquid counters are precision devices for measuring flow and consumption of non‑aggressive liquids with kinematic viscosity from 0.5 to 3000 mm²/s (cSt). They are intended for high‑power units in marine transport, power generation, petrochemical, industrial and municipal sectors. Units can operate standalone or be integrated into industrial automation, fixed‑site monitoring, machine telematics and IIoT systems.
Product family and models- LIQUANTY Gear — Oval‑gear meters for stationary installations and auxiliary ship systems. Flow range: 12 … 416 L/min. For non‑aggressive liquids 0.55 … 300 cSt. Operating fluid temperature: –20 … +90 °C.
- LIQUANTY Ring — Ring‑piston (annular chamber) meters for heavy‑duty land and rail machinery and small vessels. Flow range: 0.33 … 66 L/min. Designed for diesel fuel and heating oil. Operating fluid temperature: –40 … +95 °C.
- LIQUANTY Corio — Coriolis (mass and volumetric) meters for marine applications and industrial pipelines. Flow range: 7 … 6700 L/min. Operating fluid viscosity: 0.5 … 3000 cSt. Operating fluid temperature: –60 … +100 °C.
Key functions and outputs- Accurate liquid flow measurement (total and mode‑based counters).
- Recording of pump or consumer operating time; mode‑based operating time (Idling, Regular, Overload).
- Theft prevention by flow monitoring.
- Liquid temperature and density monitoring (where applicable, e.g., Corio).
- Informative digital display with multiple parameter screens; local monitoring and ledger functions.
- Data transmission interfaces for system integration: CAN J1939, pulse outputs, RS‑485/Modbus, Bluetooth Low Energy.
- Built‑in battery for autonomous operation and data storage when external power is off.
Advantages of LIQUANTY liquid counters- High measurement accuracy — from ±0.15% (critical for flow monitoring in industrial and energy facilities).
- Wide viscosity coverage — suitable for non‑aggressive liquids from 0.55 to 3000 cSt depending on model.
- Versatility — applicable in power generation, petrochemical, heavy machinery, marine transport, municipal and industrial sectors.
- Model range — measurement from 0.33 to 6700 L/min; available as standalone and interface‑enabled versions.
- Real‑time data control — local display and transmission to recording and telematics systems.
- System integration — compatible with local automation and remote IIoT platforms.
- Designed for operation under harsh conditions (vibration, temperature and pressure variations).
Specifications — LIQUANTY GearModel | LIQUANTY Gear 120 | LIQUANTY Gear 410
Minimum liquid flow rate, L/min | 12 | 41
Maximum liquid flow rate, L/min | 120 | 416
Relative error, max, % | 0.25 (both models)
Working fluid viscosity, mm²/s (cSt) | 0.55 … 300 (calibrated at production)
Maximum working fluid temperature, °C | 90 (both models)
Maximum working fluid pressure, MPa | 1.6 (both models)
Interfaces | CAN J1939, pulse, RS‑485 (optional converter)
Ingress protection | IP54 (IP67 available on request)
Connection types | Gear 120: flanged, threaded; Gear 410: flanged
Weight, max, kg | Gear 120: 5.4; Gear 410: 14.6
Specifications — LIQUANTY RingModel | LIQUANTY Ring 15 | LIQUANTY Ring 30 | LIQUANTY Ring 65
Minimum liquid flow rate, L/min | 0.33 | 0.66 | 1.33
Maximum liquid flow rate, L/min | 16.5 | 33.0 | 66.0
Relative error, % | ≤ 0.5 (all models)
Working fluid viscosity, mm²/s (cSt) | 1.5 … 6.0
Maximum liquid temperature, °C | 95 (all models)
Maximum liquid pressure | 25 bar (flanged) / 16 bar (threaded)
Interfaces | Autonomous, CAN J1939, pulse, wireless (Bluetooth)
Connection types | Flanged or threaded
Weight, max, kg | Ring 15: 4.3; Ring 30: 6.3; Ring 65: 9.3
Specifications — LIQUANTY CorioModel | Mass flow rate, t/h | Volume flow rate, L/min | Nominal diameter, mm
LIQUANTY Corio 95 | 0.35 – 5.2 | 7 – 100 | 15
LIQUANTY Corio 380 | 1.3 – 20 | 25 – 380 | 25
LIQUANTY Corio 1200 | 4 – 65 | 77 – 1240 | 50
LIQUANTY Corio 2300 | 10 – 120 | 192 – 2300 | 80
LIQUANTY Corio 3800 | 27 – 200 | 514 – 3800 | 100
LIQUANTY Corio 6700 | 30 – 350 | 575 – 6700 | 150
Liquid temperature range | –60 … +100 °C
Operating pressure range | 0 … 4 MPa
Accuracy volume / mass | ±0.21% / ±0.16% for diesel fuel
Output interface | RS‑485 (Modbus RTU)
Pipeline connection | Flange
Data displayed and logged (general)- Total liquid consumption (total counter).
- Total operating time of the counter.
- Liquid consumption and operating time by operating modes.
- Clearable consumption and operating time counters.
- Temperature in the measuring chamber (where applicable).
- Mass flow, volume flow, liquid temperature and density (Coriolis models).
Applications- High‑power diesel gensets, heaters and boiler/heating systems.
- Fuel delivery trucks and tankers; fuel transfer and dispensing systems.
- Marine engines and diesel generators, tugs, medium/small vessels and ferries.
- Mining and quarry equipment (dump trucks, excavators, bulldozers).
- Power units for ferries, tugs, medium‑size ships; railway equipment power units.
- Petrochemical, oil & gas and chemical industries; industrial pipelines.
Technical specifications- Kinematic viscosity operating range (overall): 0.5 – 3000 mm²/s (cSt) depending on model.
- Flow measurement range (overall): 0.33 – 6700 L/min depending on model.
- Temperature ranges: Gear: –20 … +90 °C; Ring: –40 … +95 °C; Corio: –60 … +100 °C.
- Measurement accuracy examples: Gear: max relative error 0.25%; Ring: ≤0.5%; Corio: volume ±0.21% / mass ±0.16% (diesel fuel).
- Interfaces: CAN J1939, pulse outputs, RS‑485 (Modbus RTU), Bluetooth Low Energy (BLE); some models autonomous.
- Ingress protection: IP54 standard; IP67 available on request (Gear).
- Connection types: Flanged and/or threaded; pipeline flange for Corio.
- Operating pressure: up to 1.6 MPa (Gear); Ring up to 25 bar (flanged) / 16 bar (threaded); Corio up to 4 MPa depending on model.
- Autonomous operation: built‑in battery for data logging and operation without external power (depending on configuration).
- Display: informative digital display with multiple counters and parameter screens for local monitoring.