Product overviewLIQUANTY liquid counters are precision metering devices for non‑aggressive liquids across a wide kinematic viscosity range (0.5–3000 mm²/s). Designed for industrial and mobile heavy‑duty applications, they support standalone operation or integration into automation, telematics and IIoT platforms for monitoring consumption, operating time and process diagnostics.
Models- LIQUANTY Gear — Oval‑gear meters for stationary installations and ship auxiliary systems. Typical media: light petroleum products (diesel, heating oil) and non‑aggressive additives. Functions: total and partial volume metering, operating time recording and flow dispensing control.
- LIQUANTY Ring — Ring‑piston meters for heavy land and rail machinery and small vessels. Optimised for diesel and heating oil; provides accurate total consumption and operating/load time data.
- LIQUANTY Corio — Coriolis mass/volume meters for marine and industrial pipelines. Provides simultaneous mass, volume, temperature and density measurement with low pressure loss.
Advantages of LIQUANTY liquid counters- High measurement accuracy — from ±0.15% for selected models.
- Wide viscosity coverage — suitable for non‑aggressive liquids from 0.5 to 3000 cSt.
- Application versatility — power generation, petrochemical, marine transport, heavy machinery, municipal and industrial sectors.
- Model range — flow coverage from 0.33 to 6700 L/min; available as autonomous or interface‑enabled versions.
- Real‑time monitoring — integrated display with transmission to recording devices and remote systems.
- System integration — CAN J1939, pulse, Bluetooth Low Energy; optional RS‑485/Modbus and converters.
Design advantages (examples)- Measuring chamber with oval gears — stable accuracy across a broad viscosity range.
- Informative digital display — multiple operating counters for local monitoring.
- Built‑in battery option — autonomous data storage and operation without external power.
- Multiple interfaces — CAN J1939, pulse, BLE; optional RS‑485/Modbus for remote integration.
- Resistance to vibration, temperature and pressure fluctuations; long service life and reduced maintenance.
Applications (examples)- High‑power diesel gensets and heating units.
- Fuel delivery trucks, tankers and dispensing systems.
- Petrochemical production and fuel transfer systems.
- Power units for ferries, tugs, medium‑size ships and railway equipment.
- Mining trucks, excavators, bulldozers and heavy‑duty oil & gas equipment.
- Work vessels, ferries, boiler and heating systems.
Data on display and in output interface- Total liquid consumption (volume and/or mass).
- Total operating time of the counter.
- Consumption by operating modes and operating time by modes (Idling, Regular, Overload).
- Resettable consumption counters where applicable.
- Measuring chamber temperature and battery status.
- Mass flow, volume flow, liquid temperature and density (Corio models).
Characteristics / technical specifications- LIQUANTY Gear — Overview
Flow examples: 12 … 416 L/min.
Viscosity (calibrated): 0.55 … 300 cSt.
Fluid temperature: –20 … +90 °C.
Max working pressure: 1.6 MPa.
Interfaces: CAN J1939, pulse, RS‑485 (optional).
Ingress protection: IP54 (IP67 on request).
Connections: flanged or threaded (model dependent).
Weight examples: Gear 120 ≈ 5.4 kg; Gear 410 ≈ 14.6 kg. - LIQUANTY Ring — Overview
Designed for diesel and heating oil. Flow examples: 0.33 … 66 L/min.
Fluid temperature: –40 … +95 °C.
Interfaces: autonomous, CAN J1939, pulse, Bluetooth.
Connections: flanged or threaded.
Weight examples: Ring 15 ≈ 4.3 kg; Ring 30 ≈ 6.3 kg; Ring 65 ≈ 9.3 kg. - LIQUANTY Corio — Overview
Coriolis mass/volume meters with low flow resistance. Suitable for marine fuel oil, technical water and various non‑aggressive liquids; designed for large vessels and industrial pipelines. - LIQUANTY Corio — Models (examples)
Corio 95: 7–100 L/min (DN15) | Corio 380: 25–380 L/min (DN25)
Corio 1200: 77–1240 L/min (DN50) | Corio 2300: 192–2300 L/min (DN80)
Corio 3800: 514–3800 L/min (DN100) | Corio 6700: 575–6700 L/min (DN150)
Liquid temp range: –60 … +100 °C. Operating pressure: 0 … 4 MPa.
Accuracy (diesel): volume ±0.21% / mass ±0.16%.
Output: RS‑485 (Modbus RTU). Pipeline connection: flange.