Test probe AP033
activevoltagefor oscilloscopes

Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes - image - 2
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes - image - 3
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes - image - 4
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes - image - 5
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes - image - 6
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes - image - 7
Test probe - AP033 - Teledyne LeCroy Europe - active / voltage / for oscilloscopes - image - 8
Add to favorites
Compare this product

Characteristics

Type
test, active
Measured value
voltage
Applications
for oscilloscopes
Domain
for electronics

Description

Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required. Wide Dynamic Range: The AP033 provides a range of sensitivities from x10 gain to ÷10 attenuation (even ÷100 with plug-on attenuator) for diverse signals. The sensitivity can be adjusted continuously from 200 µV/div to 1 V/div, when used with a LeCroy oscilloscope. At high sensitivities, the x10 GAIN and the ÷1 ATTENUATION are selected. This produces 4 nV/√Hz input noise, ±5 V of common mode voltage range (CMVR), and ±400 mV of DC differential offset. At lower sensitivities, the x1 GAIN and ÷10 ATTENUATION are selected, resulting in ±50 V CMVR and ±4 V of differential offset. The input capacitance is just 2 pF/side (1 pF differential) whenever the ÷10 ATTENUATION is selected. Deflection factors of 2 mV/div to 1 V/div can be obtained with only 2 pF/side input capacitance and ±50 V CMVR. DC CMRR is greater than 10,000:1 (80 dB) in both ATTENUATION settings. OFFSET up/down buttons allow OFFSET control from the probe amplifier body. Momentarily holding both buttons will zero the OFFSET. A supplied AC coupling capacitor head (0.1 µF) allows operation with large common mode or differential DC inputs. The input attenuator automatically changes from ÷1 to ÷10 when too much common mode signal is sensed.

Other Teledyne LeCroy Europe products

Oscilloscopes

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.