video corpo
cad

Wall-mount humidity and temperature sensor FTB+ active
relativeabsoluteflush-mount

Wall-mount humidity and temperature sensor - FTB+ active - Thermokon Sensortechnik - relative / absolute / flush-mount
Wall-mount humidity and temperature sensor - FTB+ active - Thermokon Sensortechnik - relative / absolute / flush-mount
Add to favorites
Compare this product

Characteristics

Type
relative, absolute
Mounting
wall-mount, flush-mount
Technology
resistance
Output
4-20 mA, 0-10 V, 0-5 V
Supply voltage
24VDC, 15VDC
Electrical connection
terminal block
Protection level
IP65
Other characteristics
stainless steel
Applications
for indoor use
Measuring range (%)

Min.: 0 %

Max.: 100 %

Precision

2 %

Measuring range (temperature)

Min.: -40 °C
(-40 °F)

Max.: 80 °C
(176 °F)

Accuracy (temperature)

0.3 °C
(32.54 °F)

Working temperature

Min.: -40 °C
(-40 °F)

Max.: 120 °C
(248 °F)

Description

Wall-mounted sensor for measuring relative humidity and temperature in a high quality and inconspicious stainless steel design. For plastering into flush-mounted boxes or installations in hollow walls. Especially designed for museums and exhibitions, where measuring accuracy and almost invisible sensors have to be installed due to architectural design. The precise measurements provided to a BMS system contribute to a comfortable room climate and prevent mold formation. • Application/type : Room sensor • Purpose : Measure values • Measured values : temperature, relative humidity, absolute humidity, enthalpy, dew point • Interface : Active, 0..5 V, 0..10 V, 4..20 mA • Configuration : jumper • Output voltage : 2x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ • Output current : 2x 4..20 mA, max. load 500 Ω • Output switch contact : 2x floating contact NO for 24 V ~ or 24 V = / 3 A • Operating range temperature (°C) : -40..+120 • Output signal temperature : scaling analogue output, -20..+80 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, adjustable at the transducer, optionally configurable • Operating range humidity : max. 85% rH short term condensation • Accuracy temperature : ±0,3 K (typ. at 21 °C), within default measuring range, potentiometer for offset adjustment, offset setting via app or uConfig • Measuring range humidity : 0..100% rH non-condensing, 0..85 KJ/kg enthalpy, 0..50 | 0..80 g/m³ absolute humidity, 0..+50 | -20..+80 °C dew point, adjustable at the transducer, optionally configurable

Catalogs

Products 2018
Products 2018
460 Pages
Products
Products
428 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.