video corpo
cad

Outdoor humidity and temperature sensor WSA active
relativeabsolutewall-mount

Outdoor humidity and temperature sensor - WSA active - Thermokon Sensortechnik - relative / absolute / wall-mount
Outdoor humidity and temperature sensor - WSA active - Thermokon Sensortechnik - relative / absolute / wall-mount
Outdoor humidity and temperature sensor - WSA active - Thermokon Sensortechnik - relative / absolute / wall-mount - image - 2
Add to favorites
Compare this product

Characteristics

Type
relative, absolute
Mounting
wall-mount
Technology
Pt100, Pt1000
Output
4-20 mA, 0-10 V, 0-5 V
Supply voltage
24VDC, 15VDC
Protection level
IP65
Other characteristics
with integrated digital display
Applications
for industrial applications, outdoor
Measuring range (%)

Max.: 100 %

Min.: 0 %

Precision

2 %

Measuring range (temperature)

Max.: 80 °C
(176 °F)

Min.: -40 °C
(-40 °F)

Accuracy (temperature)

0.2 °C, 0.3 °C, 0.4 °C
(32.36 °F, 32.54 °F, 32.72 °F)

Working temperature

Max.: 70 °C
(158 °F)

Min.: -20 °C
(-4 °F)

Description

Weatherproof humidity and temperature sensor for outdoor applications. The radiation shield protects the sensors from rain, hail and radiated heat. The curved shape of the plates ensure that air can move across the sensors to keep radiated temperature from rooftops and other surrounding surfaces away and guarantee proper measurement. Typical applications are meteorology, greenhouses and industrial environments. • Application/type : Outdoor sensor • Purpose : Measure values • Measured values : temperature, relative humidity, absolute humidity, enthalpy, dew point • Interface : Passive, Active, 0..5 V, 0..10 V, 4..20 mA • Configuration : jumper • Sensor : NTC10k, Pt1000 DIN cl. B, Ni1000 DIN cl. B, Pt1000 1/3 DIN, Pt100 DIN cl. B, Ni1000TK5000, Pt100 1/3 DIN, NTC10k Precon, NTC10k Carel, NTC1,8k, NTC5k, NTC20k, LM235Z, DS18B20 1-wire, additional passive sensor • Output voltage : 2x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ • Output current : 2x 4..20 mA, max. load 500 Ω • Output signal temperature : scaling analogue output, -20..+80 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, adjustable at the transducer, depending on used sensor • Operating range humidity : max. 85% rH short term condensation • Accuracy temperature : ±0,3 K (typ. at 21 °C), within default measuring range, ±0,3 K (typ. at 0 °C), ±0,4 K (typ. at 0 °C), ±0,2 K (typ. at 25 °C, temperature dependend), potentiometer for offset adjustment