The HAT valve is a temperature-activated valve that is designed to open on falling temperatures to keep systems warm during the freeze season. It can be used to control fluid temperatures in glycol heat tracing systems, tank heating coils, sampling systems, condensate systems, as a subcooling steam trap, and for countless other applications.
Operation
A thermal wax actuator mechanically operates ThermOmegaTech’s self-operating HAT (heat actuated trap) valve. This thermostatic actuator senses the fluid temperature and will modulate the valve open to initiate flow if the temperature falls below the valve’s set point. Once the fluid temperature increases back to the set-point, the valve will modulate closed to control flow. HAT valves are available with built-in leakage to allow bypass flow.
Typical Applications
A subcooling steam trap: discharges condensate to an unpressurized outlet, reducing problems associated with overheating.
Regulating temperatures in glycol heat tracing: maintains the discharge temperature for glycol heat tracing used for winterization processes.
Freeze protection for condensate systems: The heat-actuated trap valves open when temperatures fall to allow condensate to discharge before freezing.
High-temperature for commercial aircraft galleys: HAT valves are installed in airplane galleys where manifolds connect coffee makers and faucets to prevent high-temperature water from traveling to the cold-water lines and scalding passengers and/or crew.
Regulating temperatures of tank heating coils: HAT valves limit the temperatures of the heating element by closing before coil temperatures are too high to reduce the risk of over-temperature damage.