Ultrasonic level transmitter XY‑CT
for waterfor wastewaterfor liquids

Ultrasonic level transmitter - XY‑CT - Xi'an Yunyi Instrument Co., Ltd. - for water / for wastewater / for liquids
Ultrasonic level transmitter - XY‑CT - Xi'an Yunyi Instrument Co., Ltd. - for water / for wastewater / for liquids
Add to favorites
Compare this product

Characteristics

Technology
ultrasonic
Medium
for liquids, for water, for wastewater, for slurry
Interface
analog, 4-20 mA, digital output, RS-485, Modbus
Applications
for industrial applications, for the food industry, for monitoring, for hazardous areas, for small access holes
Approvals
ATEX
Other characteristics
stainless steel, compact, high-precision, intrinsically safe, temperature-compensated, miniature, IP65
Level range

1 m, 2 m
(3'03" , 6'06" )

Description

Overview
The YUNYI XY‑CT Series is a miniature ultrasonic level transmitter engineered for installations with very limited space that still require high measurement precision. It offers an ultra‑small blind zone (as low as <0.06 m on select ranges), high resolution accuracy (±1 mm to ±1.5 mm depending on range) and compact housing options in 304 stainless steel or copper‑plated finish. The transmitter uses an industrial‑grade microcontroller with digital temperature compensation, ultra‑wide voltage input regulation and specialised integrated circuits for stable long‑term operation.

Key Features
  • Ultra‑small blind zone – down to <0.06 m for proximity mounting to the measured surface.
  • High precision – accuracy from ±1 mm to ±1.5 mm depending on selected range.
  • Compact rugged housing – Φ28 mm × 100 mm (M30×1.5 thread) suitable for confined installations; materials: 304 stainless steel or copper‑plated.
  • Automatic temperature compensation – built‑in sensor provides real‑time compensation for stable readings.
  • Strong anti‑interference design – suitable for electrically noisy industrial environments.
  • Flexible outputs – analog (0‑20mA, 4‑20mA, 0‑5V, 0‑10V), digital (RS485 with Modbus) or switch output; configurable upper/lower setpoints via host software.
  • Non‑contact measurement – avoids fouling, clogging, leakage and corrosion, reducing maintenance.
  • Intrinsic safety – Ex ia IIB T4 Gb explosion protection certification.
  • Wide input voltage – DC 12‑24V with ultra‑low power consumption <1.5W.
  • Easy installation – M30×1.5 thread; supplied with 1.5 m cable.


Simple Technical Overview (No Table)
  • Measurement range: 1 m or 2 m (order selectable).
  • Blind zone: <0.06–0.15 m (depends on range).
  • Accuracy: ±1 mm or ±1.5 mm (depends on range).
  • Beam angle: <6° (depends on transducer).
  • Operating frequency: 40 kHz – 430 kHz (model dependent).
  • Temperature compensation: automatic, built‑in.
  • Output options: 0‑20mA, 4‑20mA, 0‑5V, 0‑10V, RS485 (Modbus), switch output.
  • Power supply: DC 12‑24V, <1.5W consumption.
  • Housing material: 304 stainless steel or copper‑plated; dimensions Φ28 mm × 100 mm.
  • Mounting: M30×1.5 thread; cable length supplied: 1.5 m.
  • Ingress protection: IP65 (higher ratings on request).
  • Explosion protection: Ex ia IIB T4 Gb (meets GB3836.1‑2010 and GB3836.4‑2010).
  • Operating environment: normal temperature and pressure.
  • Storage: humidity ≤80% RH, non‑condensing.


Where It's Used
  • Water & wastewater treatment – pump stations, collection wells, biological tanks, clarifiers.
  • Power & mining – ash slurry tanks, coal slurry, grease storage, stockpile monitoring, mobile equipment control.
  • Food industry – breweries, grain silos, ingredient storage tanks and hoppers.
  • Control systems in space‑constrained installations requiring precise level measurement and low maintenance.


Technical specifications
  • Series / Model: XY‑CT Series.
  • Available ranges: 1 m, 2 m (select at order).
  • Blind zone: as low as <0.06 m (model dependent).
  • Accuracy: ±1 mm (best) to ±1.5 mm (range dependent).
  • Beam angle: typically <6°.
  • Operating frequency: 40 kHz – 430 kHz (model dependent).
  • Temperature compensation: built‑in automatic compensation.
  • Outputs: analog (0‑20mA, 4‑20mA, 0‑5V, 0‑10V), RS485 (Modbus), switch output.
  • Power: DC 12‑24V, consumption <1.5W.
  • Housing: Φ28 mm × 100 mm, M30 thread; materials: 304 stainless steel or copper‑plated.
  • Mounting/thread: M30×1.5; cable length: 1.5 m.
  • Ingress protection: IP65 (upgrade options available).
  • Explosion certification: Ex ia IIB T4 Gb (GB3836.1‑2010, GB3836.4‑2010).
  • Storage: humidity ≤80% RH, non‑condensing.