- Detection - Measurement >
- Temperature and Humidity Measurements >
- °C thermometer >
- Challenge Power Transmission
Challenge Power Transmission °C thermometers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Temperature: 40 °C - 230 °C
Resolution: 0.1 °C
... characteristics / specifications
- Measurement range: +40°C to +230°C
- Measurement accuracy: ±1°C from -10 to +100°C; ±1.5°C from +100 to +200°C;
JRI
Temperature: -50 °C - 150 °C
Resolution: 0.1 °C
... br>
- Measurement range: -50°C to +150°C
- Measurement accuracy: ±1°C from 0 to 100°C and ±2°C beyond
- Power supply: 1 LR44 button cell or equivalent
- Functions:
JRI
Temperature: -50 °C - 70 °C
Resolution: 0.1 °C
...
Technical specifications
- Measuring range: -50 °C to +70 °C
- Accuracy: ±0.5 °C (0 to 50 °C), ±1 °C (-20 to 0 °C), ±1 °C
JRI
Temperature: -50 °C - 300 °C
Resolution: 0.1 °C
... Measurement range: -50 ° C to +300 ° C
JRI
Temperature: -32 °C - 760 °C
Precision: 1 %
Spectral range: 8 µm - 14 µm
... specifications
- Measurement range: -32°C to +760°C
- Accuracy (at 23°C ±5°C): ±1% or ±1°C from 0 to 760°C; ±1.5°C
JRI
Temperature: -50 °C - 380 °C
Precision: 3 %
Spectral range: 8 µm - 14 µm
... >Measurement range: -50°
C to +380°
C
Measurement accuracy: ±3% or ±3°
C
Power supply: 9 V battery (type 6LR61)
Spectral response: 8–14 µm
Optical resolution: 8:1
Emissivity: fixed at 0.95
Repeatability: ...
JRI
Temperature: -55 °C - 330 °C
Resolution: 0.2 °C
... : ±1.1° C from -33° C to 0° C; ±1.0° C from 0° C to +65° C; ±1.5° C from +65° C to +250° C
JRI
Temperature: -50 °C - 1,300 °C
Precision: 0.3, 0.5 %
Resolution: 0.1 °C
... Protection 20V maximum input voltage Sampling Rate 2.5 time/sec Operating/Storage Conditions 0° C ~ 50° C < 80% RH , -10° C ~ 60° C< 70%RH Power Source 6 pcs size AAA Battery Battery ...
TES Electrical Electronic Corp.
Temperature: -150 °C - 1,767 °C
Precision: 0.05 %
Resolution: 0.1 °C
... reading for T] R-and S-type: ±[0.05% of reading +2° C(4°F Temperature Coefficient 0.01% of reading +0.03° C per ° C (0.06°F per °F) outside the specified +18° C to 28° C ...
TES Electrical Electronic Corp.
Temperature: -190 °C - 790 °C
Precision: 0.05 %
Resolution: 0.1 °C
... Coefficient Less that 0.1 times the applicable accuracy specification per ° C (°F) Sampling Rate One time per 1.5 seconds Operating/Storage Conditions 0° C ~ 50° C < 80% RH , -10° C ...
TES Electrical Electronic Corp.
Temperature: -150 °C - 1,767 °C
Precision: 0.05, 0.15, 0.45 %
Resolution: 0.1 °C
... Combination of input Connector Sampling Rate One time per 1.5 seconds. Operating/Storage Conditions 0° C~ 50° C < 80% RH , -10° C ~ 60° C < 70%RH Power Source 6 pcs size AAA ...
TES Electrical Electronic Corp.
Temperature: -200 °C - 1,370 °C
Precision: 0.1, 0.3 %
Resolution: 0.1 °C
... Data hold function. MAX / MIN / AVG function. Offset function. ℃ / ℉ User-Selective. 0.1℃ / 0.1℉ resolution. Auto power off function. Memory and Read function. ...
TES Electrical Electronic Corp.
Temperature: -50 °C - 1,300 °C
Precision: 0.3, 0.5 %
Resolution: 0.1 °C
... specification per° C(°F) Input Protection 60V DC or 24Vrms AC maximum input voltage on any Combination of input Connector Sampling Rate 2.5 times/sec. Ambient Operating Range 0° C~50° C (32°F~122°F) Storage ...
TES Electrical Electronic Corp.
Temperature: -50 °C - 1,300 °C
Precision: 0.3, 0.5, 0.75 %
Resolution: 1, 0.1 °C
... display T1 – T2 differential measurement Flip-up stand Auxilitary Outputs (for Data Recording) 1mV/° C (°F)…at 0.1° C/0.1°F range 0.1mV/° C (°F)…at 1° C/1°F range Temperature Coefficient Less ...
TES Electrical Electronic Corp.
Temperature: -200 °C - 1,370 °C
Precision: 0.1, 0.5, 0.2 %
Resolution: 0.1, 1 °C
... Approx. 100 hours (Alkaline Battery) Operating Temperature and Humidity - 0° C to 40° C (32°F to 104°F) below 80%RH Storage Temperature and Humidity - -10° C to 60° C (14°F to 140°F) ...
TES Electrical Electronic Corp.
Temperature: -190 °C - 1,333 °C
Precision: 0.5, 0.1, 0.2 %
Resolution: 1, 0.1 °C
... K/J Type thermocouple input Auto ranging 8000 Record Data logging Capacity Maximum / Minimum / Average reading Relative readin Input Protection 60VDC/24Vrms Power Source One 9V battery or 006P, NEDA1604 or IEC6F22 Battery Life Approx. ...
TES Electrical Electronic Corp.
Temperature: 0 °C - 100 °C
Resolution: 0.1 °C
Spectral range: 6 µm - 14 µm
... Red 3 color screen display LED light spot measurement and positioning PECIFICATIONS Resolution 0.1° C/0.2°F Accuracy 22° C to 42° C (±0.3° C) / 71.6°F to 107.6°F (±0.5°F) 107.6°F ...
TES Electrical Electronic Corp.